| Literature DB >> 36215306 |
Martin Sembera1, Andrew Busch2, Alena Kobesova1, Barbora Hanychova1, Jan Sulc1, Pavel Kolar1.
Abstract
OBJECTIVES: The diaphragm changes position and respiratory excursions during postural loading. However, it is unclear how it reacts to lifting a load while breath-holding or breathing with simultaneous voluntary contraction of the abdominal muscles (VCAM). This study analyzed diaphragm motion in healthy individuals during various postural-respiratory situations.Entities:
Mesh:
Year: 2022 PMID: 36215306 PMCID: PMC9550028 DOI: 10.1371/journal.pone.0275389
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.752
Descriptive statistics of participants (mean ± standard deviation).
| Participants | Age (yr) | Height (cm) | Weight (kg) | Waist Circumference (cm) | Waist/Height Ratio | Body Mass Index (kg/m2) |
|---|---|---|---|---|---|---|
| All (n = 31) | 28.7 ± 5.8 | 173.2 ± 8.5 | 66.2 ± 9.2 | 74.1 ± 5.9 | 0.43 ± 0.03 | 22.0 ± 1.6 |
| Males (n = 11) | 28.4 ± 5.0 | 181.0 ± 6.0 | 74.1 ± 8.0 | 78.9 ± 6.2 | 0.44 ± 0.03 | 22.6 ± 1.7 |
| Females (n = 20) | 28.9 ± 6.4 | 169.0. ± 6.4 | 61.9 ± 6.8 | 71.5 ± 3.9 | 0.42 ± 0.02 | 21.6 ± 1.4 |
Fig 1Examination procedures.
(A) Participant assessed simultaneously by M-mode ultrasonography, spirometry, and DNS brace. (B) Spirometry record displayed in Grapher software (C) M-mode view of diaphragm motion. (D) Graphical representation of recorded data from DNS Brace. All of these recordings were taken during the same examination of one participant in Scenario 2.
Intraclass correlation coefficients of ultrasonography and DNS brace values during tidal inspiration and expiration (ICC 2, k).
| 95% Confidence Interval | F Test With True Value 0 | |||||||
|---|---|---|---|---|---|---|---|---|
| Measure | ICC | Lower Bound | Upper Bound | SEM | Value | Sig | ||
| Ultrasonography | Inspiration | .985 | .970 | .993 | 1.68 | 71.63 | 30 | < .001 |
| Expiration | .989 | .978 | .995 | 1.54 | 93.40 | 30 | < .001 | |
| DNS Brace | Inspiration | .657 | .291 | .834 | 0.82 | 2.90 | 30 | .002 |
| Expiration | .569 | .136 | .789 | 0.78 | 2.57 | 30 | .006 | |
Note: ICC = Intraclass Correlation Coefficient
SEM = Standard Error of Measurement
**Denotes: Excellent reliability
*Denotes: Moderate reliability
Changes in ultrasonography values (mm) and DNS brace values (kPa) during different scenarios of holding a load equivalent to 20% body weight (mean [standard deviation]).
|
|
|
|
|
|
|
|
|
| Ultrasonography | Inspiration | 93.54 (13.59) | 93.22 (12.41) | 0.32 | (-1.69, 2.33) | 0.06 | 0.373 |
| Expiration | 114.67 (11.40) | 110.23 (10.95) | 4.45 | (2.96, 5.93) | 1.1 | < .001* | |
| DNS Brace | Inspiration | 3.69 (2.27) | 12.32 (5.99) | -8.63 | (-10.65, -6.61) | -1.57 | < .001* |
| Expiration | 2.43 (1.46) | 7.38 (3.54) | -4.95 | (-6.17, -3.73) | -1.49 | < .001* | |
|
|
|
|
|
|
|
|
|
| Ultrasonography | Inspiration | 96.94 (13.03) | 93.35 (12.92) | 3.58 | (2.07, 5.09) | 0.87 | < .001** |
| Expiration | 116.18 (14.35) | 115.42 (14.51) | 0.76 | (-0.42, 1.95) | 0.24 | 0.201 | |
| DNS Brace | Inspiration | 2.57 (1.12) | 6.02 (2.80) | -3.44 | (-4.45, -2.44) | -1.26 | < .001** |
| Expiration | 2.41 (1.08) | 6.47 (3.41) | -4.06 | (-5.23, -2.89) | -1.28 | < .001** | |
| Ultrasonography | Excursion | 19.24 (6.85) | 22.06 (8.79) | -2.82 | (-4.48, -1.16) | -0.63 | .002** |
|
|
|
|
|
|
|
|
|
| Ultrasonography | Inspiration | 93.35 (12.92) | 90.74 (14.89) | 2.61 | (-0.26, 5.49) | 0.33 | 0.037 |
| Expiration | 115.42 (14.51) | 112.05 (12.93) | 3.36 | (0.05, 6.68) | 0.37 | 0.023 | |
| DNS Brace | Inspiration | 6.02 (2.80) | 12.70 (6.05) | -6.68 | (-8.26, -5.09) | -1.55 | < .001** |
| Expiration | 6.47 (3.41) | 12.10 (6.01) | -5.63 | (-7.49, -3.77) | -1.11 | < .001** | |
| Ultrasonography | Excursion | 22.06 (8.79) | 20.42 (9.54) | 1.65 | (-0.97, 4.26) | 0.23 | 0.104 |
aSubject holds breath at the end of full Inspiration and Expiration
bSubject holds load with natural breathing and spontaneous abdominal activity
cSubject voluntarily contracts abdominal muscles prior to holding load while breathing naturally
Note: VCAM: Voluntary contraction of abdominal muscles
Effect size = calculated Cohen’s d
*Statistically significant difference observed (Bonferroni Correction P < 0.025)
**Statistically significant difference observed (Bonferroni Correction P < 0.016)
Fig 2Graph showing outcomes of each scenario.
(A) Diaphragm position, excursions (mm), and (B) abdominal wall tension (kPa) during breath-holding, tidal breathing, loaded breathing, and loaded breathing with VCAM (Mean ± Standard Deviation).