Current imaging modalities can provide only a qualitative or semiquantitative measure of the severity of aortic regurgitation. Ultrafast computed tomography (CT) has the capability of rapid imaging (17 frames/sec) coupled with high spatial resolution (1.5 mm2). Eight millimeter thick images can be acquired to interrogate simultaneously the right and left ventricles. End-diastolic and end-systolic tomograms can be reconstructed serially from apex to base by Simpson's rule to provide end-diastolic and end-systolic volumes from which the right and left ventricular stroke volumes can be derived. To determine whether the difference between left and right ventricular stroke volume measured with ultrafast CT could be used to estimate the volume of experimentally induced aortic regurgitation, we studied six dogs in which proximal aortic electromagnetic flow probes had been implanted. Varying degrees of aortic regurgitation were induced by manipulation of a basket catheter through the aortic valve. During suspended respiration in the control state in the absence of aortic regurgitation, right and left ventricular stroke volumes measured with ultrafast CT were nearly identical (mean difference 1.0 +/- 1.2 ml [mean +/- SE]). In the presence of varying degrees of aortic regurgitation, regurgitant volume derived by ultrafast CT as the difference between right and left ventricular stroke volumes correlated closely to the regurgitant volume measured by the electromagnetic flow probe (r = .99, slope = .92, y intercept = 0.98 ml, SEE = 1.02 ml, n = 16). Regurgitant fraction also correlated closely to the regurgitant fraction measured by the electromagnetic flow probe (r = .94, slope = .98, y intercept = 0.66%, SEE = 4.73%, n = 16).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1987        PMID: 3621530     DOI: 10.1161/01.cir.76.3.728

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  5 in total

Review 1.  Ultrafast CT and the cardiovascular system.

Authors:  M S Bleiweis; D Georgiou; B H Brundage
Journal:  Int J Card Imaging       Date:  1992

Review 2.  Advances in cardiovascular CT imaging: CT clinical imaging.

Authors:  William Stanford
Journal:  Int J Cardiovasc Imaging       Date:  2005-02       Impact factor: 2.357

3.  Reproducibility of right and left ventricular volume measurements by electron-beam CT in patients with congestive heart failure.

Authors:  A Schmermund; B J Rensing; P F Sheedy; J A Rumberger
Journal:  Int J Card Imaging       Date:  1998-06

4.  [The use of cross-sectional imaging modalities in the diagnosis of valvular heart disease].

Authors:  M Gutberlet; H Abdul-Khaliq; H Stobbe; M Fröhlich; B Spors; F Knollmann; P Lange; R Hetzer; R Felix
Journal:  Z Kardiol       Date:  2001-12

5.  Real-time three-dimensional color Doppler flow imaging: an improved technique for quantitative analysis of aortic regurgitation.

Authors:  Qing Lu; Xiatian Liu; Mingxing Xie; Xinfang Wang; Jing Wang; Lei Zhuang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2006
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.