Literature DB >> 36178493

Long-term survivorship of an exchangeable-neck hip prosthesis with a Ti-alloy/Ti-alloy neck-stem junction.

Massimiliano Baleani1, Aldo Toni2, Cristina Ancarani3, Susanna Stea3, Barbara Bordini3.   

Abstract

INTRODUCTION: Breakage of exchangeable-neck (EN) and adverse local tissue reactions (ALTRs) to neck-stem junction (NSJ) damage products are responsible for increasing the revision rate of EN hip prostheses. We investigated the survivorship of an EN hip prosthesis including a NSJ with both components made of titanium alloy (Ti-alloy/Ti-alloy) to assess whether, and to what extent, EN breakage and NSJ damage affected implant survivorship.
MATERIALS AND METHODS: Using data from a hip replacement registry, we determined survivorship of 2857 EN prostheses. Long-offset configurations of head and EN were implanted in heavy (> 90 kg) patients only in 23 hips. We investigated under which conditions EN breakages or ALTRs occurred. We also measured titanium (Ti) and vanadium (V) blood concentrations in 24 patients with a unilateral well-working prosthesis.
RESULTS: The 17-year survival rates for any reason and aseptic loosening of any component were 88.9% (95%CI 87.5-90.1; 857 hips at risk) and 96.9% (95%CI 96.0-97.6), respectively. There were two cases of EN breakage and one case of ALTR (metallosis), due to rim-neck impingement, out of 276 revisions. After an average period of 9.8 years (range 7.8-12.8 years), the maximum Ti and V blood concentrations in patients with a well-working prosthesis were 5.0 µg/l and 0.16 µg/l, respectively.
CONCLUSION: The present incidence of EN breakage or ALTR is lower than those reported in other studies evaluating EN hip prosthesis survivorship. This study suggests that (i) the risk of EN breakage is reduced by limiting the use of long-offset configurations in heavy patients and (ii) Ti-alloy/Ti-alloy NSJ damage products do not promote ALTR nor significantly alter the rate of implant loosening. Since design decisions and implant configuration determine the NSJ strength, the NSJ strength in working conditions must be thoroughly investigated to proper define the clinical indications for any EN design.
© 2022. The Author(s).

Entities:  

Keywords:  Adverse local tissue reaction; Adverse reaction to metal debris; Exchangeable-neck breakage; Fretting corrosion; Hip prosthesis; Survival rate; Ti-alloy; Ti-alloy exchangeable-neck

Year:  2022        PMID: 36178493     DOI: 10.1007/s00402-022-04634-8

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   2.928


  24 in total

1.  What Factors Are Associated With Neck Fracture in One Commonly Used Bimodular THA Design? A Multicenter, Nationwide Study in Slovenia.

Authors:  Simon Kovač; Blaž Mavčič; Marko Kotnik; Vesna Levašič; Mateja Sirše; Samo Karel Fokter
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

2.  A Single-Center Experience With a Titanium Modular Neck Total Hip Arthroplasty.

Authors:  Wade T Gofton; Emmanuel M Illical; Robert J Feibel; Paul R Kim; Paul E Beaulé
Journal:  J Arthroplasty       Date:  2017-03-20       Impact factor: 4.757

3.  Why do some titanium-alloy total hip arthroplasty modular necks fail?

Authors:  Samo K Fokter; Andrej Moličnik; Rajko Kavalar; Primož Pelicon; Rebeka Rudolf; Nenad Gubeljak
Journal:  J Mech Behav Biomed Mater       Date:  2016-12-27

4.  Early Outcomes of Revision Surgery for Taper Corrosion of Dual Taper Total Hip Arthroplasty in 187 Patients.

Authors:  Dimitris Dimitriou; Ming Han Lincoln Liow; Tsung-Yuan Tsai; William A Leone; Guoan Li; Young-Min Kwon
Journal:  J Arthroplasty       Date:  2016-01-21       Impact factor: 4.757

5.  High Risk of Failure With Bimodular Femoral Components in THA.

Authors:  Aidin Eslam Pour; Robert Borden; Takayuki Murayama; Mary Groll-Brown; J David Blaha
Journal:  Clin Orthop Relat Res       Date:  2015-09-01       Impact factor: 4.176

6.  Responses of trace elements to aerobic maximal exercise in elite sportsmen.

Authors:  Aynur Otag; Muhsin Hazar; Ilhan Otag; Alper Cenk Gürkan; Ilyas Okan
Journal:  Glob J Health Sci       Date:  2014-02-21

7.  Cardiac transplant due to metal toxicity associated with hip arthroplasty.

Authors:  Sheldon Moniz; Sean Hodgkinson; Piers Yates
Journal:  Arthroplast Today       Date:  2017-03-11

8.  Exchangeable Femoral Neck (Dual-Modular) THA Prostheses Have Poorer Survivorship Than Other Designs: A Nationwide Cohort of 324,108 Patients.

Authors:  Sandrine Colas; Assia Allalou; Antoine Poichotte; Philippe Piriou; Rosemary Dray-Spira; Mahmoud Zureik
Journal:  Clin Orthop Relat Res       Date:  2017-02-13       Impact factor: 4.176

9.  Unexpected varus deformity and concomitant metal ion release and MRI findings of modular-neck hip stems: descriptive RSA study in 75 hips with 8 years' follow-up.

Authors:  Sverrir Kiernan; Bart Kaptein; Carl Flivik; Martin Sundberg; Gunnar Flivik
Journal:  Acta Orthop       Date:  2020-12-10       Impact factor: 3.717

10.  Modular titanium alloy neck adapter failures in hip replacement--failure mode analysis and influence of implant material.

Authors:  Thomas M Grupp; Thomas Weik; Wilhelm Bloemer; Hanns-Peter Knaebel
Journal:  BMC Musculoskelet Disord       Date:  2010-01-04       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.