| Literature DB >> 36136854 |
Cristina Maria Blebea1, Violeta Necula1,2, Monica Potara3, Maximilian George Dindelegan1, Laszlo Peter Ujvary1, Emil Claudiu Botan4, Alma Aurelia Maniu1,2, Marcel Cosgarea1.
Abstract
INTRODUCTION: During cochlear implantation, electrode insertion can cause cochlear damage, inflammation, and apoptosis, which can affect the residual hearing. Nanoparticles are increasingly studied as a way to increase the availability of inner ear protective factors. We studied the effect on rats of Pluronic-coated gold nanoparticles (Plu-AuNPs) containing dexamethasone, which were applied locally in the rat's middle ear following the implant procedure.Entities:
Keywords: ABR; Pluronic; cochlear implant; dexamethasone; hearing loss; nanomaterials
Year: 2022 PMID: 36136854 PMCID: PMC9498366 DOI: 10.3390/audiolres12050047
Source DB: PubMed Journal: Audiol Res ISSN: 2039-4330
Figure 1Left ear electrode analog insertion; 1—round window niche; 2—stapedial artery; 3—middle ear, seen through the bony defect; 4—electrode analog during the insertion through the round window membrane. (A): Opening of the left middle ear, (B): Visualization of the RW, (C): Left ear electrode analog insertion.
Figure 2(A) Normalized UV-Vis absorption spectra of AuNPs (black) and Plu-AuNPs (green). (B) Normalized UV-Vis absorption spectra of AuNPs (black), Dex-AuNPs (red), and Plu-Dex-AuNPs (blue). The inserts show the magnified spectral region of the absorption maxima.
Preoperative frequency-specific hearing threshold (dB SPL) for both the Dex-Plu-AuNP and Dex groups.
| Stimuli | Dex-Plu-AuNPs ( | Dex ( | |||
|---|---|---|---|---|---|
| Threshold Mean (dB SPL) | SD | Threshold Mean (dB SPL) | SD | ||
| Click | 20 | 0 | 20 | 0 | - |
| 8 kHz | 20 | 0 | 20.7 | 1.8 | 0.35 |
| 16 kHz | 20 | 0 | 20.7 | 1.8 | 0.35 |
| 24 kHz | 20 | 0 | 20 | 0 | - |
| 32 kHz | 21.4 | 10.6 | 22.85 | 5.6 | 0.59 |
The two-tailed t-test indicates no significant difference between groups (p > 0.05); SD = standard deviation; dB SPL = decibel sound pressure level; kHz = kilohertz; n = number of subjects.
Postoperative frequency-specific hearing threshold (SPL dB) for both the Dex-Plu-AuNP and Dex cohorts.
| Stimuli | Group | N | Mean dB SPL | Std. Deviation | Std. Error Mean |
|---|---|---|---|---|---|
| clickpost | Dex-Plu-AuNPs | 7 | 63.57 | 28.536 | 10.785 |
| Dex | 7 | 74.29 | 21.876 | 8.268 | |
| post8 kHz | Dex-Plu-AuNPs | 7 | 87.86 | 23.954 | 9.054 |
| Dex | 7 | 108.57 | 6.901 | 2.608 | |
| post16 kHz | Dex-Plu-AuNPs | 7 | 97.14 | 18.225 | 6.888 |
| Dex | 7 | 108.57 | 14.351 | 5.424 | |
| post24 kHz | Dex-Plu-AuNPs | 7 | 70.71 | 16.439 | 6.213 |
| Dex | 7 | 79.29 | 14.840 | 5.609 | |
| post32 kHz | Dex-Plu-AuNPs | 7 | 87.14 | 11.852 | 4.480 |
| Dex | 7 | 92.86 | 10.746 | 4.062 |
Dex-Plu-AuNPs = Pluronic-coated gold nanoparticles with dexamethasone; Dex = free form of dexamethasone; dB SPL = decibel sound pressure level; kHz = kilohertz; post = postoperative.
Figure 3Representation of postoperative hearing threshold for rats in both groups, measured through auditory brainstem response. Results are presented as individual values for each subject at a specific frequency. (A) 8 kHz; (B) 16 kHz; (C) 24 kHz; (D) 32 kHz; dB SPL = sound pressure level expressed in decibels; Dex-Plu-AuNP= Pluronic-coated gold nanoparticles with dexamethasone; Dex = free form of dexamethasone; kHz = kilohertz; S = subject.
Figure 4Postoperative hearing threshold using click stimuli; dB SPL = sound pressure level expressed in decibels; Dex-Plu-AuNPs = Pluronic-coated gold nanoparticles with dexamethasone; Dex = free form of dexamethasone; kHz = kilohertz; S = subject.