Literature DB >> 3611127

Resultant lower extremity joint moments in below-knee amputees during running stance.

D I Miller.   

Abstract

Resultant flexion/extension lower extremity joint moments of four below-knee amputees running between 2.5 and 5.7 m s-1 were computed during stance on their intact and prosthetic limbs. All subjects wore patellar tendon-bearing prostheses with either a SACH or Greissinger foot component. During stance on the prosthesis, the resultant hip extensor moment on the amputated side was greater in magnitude and duration than its counterpart on the intact limb during its corresponding stance period. Since the artificial foot was planted on the ground, such a moment may help control knee flexion and promote knee extension of the residual limb. For the three subjects whose knees continued to flex at the beginning of stance, there was a dominant extensor moment about the knee joint during stance on the prosthesis. By contrast, for the fourth subject whose knee remained straight or hyperextended throughout stance on the prosthesis, a flexor moment was dominant.

Mesh:

Year:  1987        PMID: 3611127     DOI: 10.1016/0021-9290(87)90253-3

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  Amputee Locomotion: Joint Moment Adaptations to Running Speed Using Running-Specific Prostheses after Unilateral Transtibial Amputation.

Authors:  Brian S Baum; Hiroaki Hobara; Kyung Koh; Hyun Joon Kwon; Ross H Miller; Jae Kun Shim
Journal:  Am J Phys Med Rehabil       Date:  2019-03       Impact factor: 2.159

2.  Amputee locomotion: determining the inertial properties of running-specific prostheses.

Authors:  Brian S Baum; Melanie P Schultz; Andrea Tian; Benjamin Shefter; Erik J Wolf; Hyun Joon Kwon; Jae Kun Shim
Journal:  Arch Phys Med Rehabil       Date:  2013-03-28       Impact factor: 3.966

3.  Vacuum level effects on gait characteristics for unilateral transtibial amputees with elevated vacuum suspension.

Authors:  Hang Xu; Kasey Greenland; Donald Bloswick; Jie Zhao; Andrew Merryweather
Journal:  Clin Biomech (Bristol, Avon)       Date:  2017-02-14       Impact factor: 2.063

4.  The Effects of Prosthesis Inertial Parameters on Inverse Dynamics: A Probabilistic Analysis.

Authors:  Brecca M M Gaffney; Cory L Christiansen; Amanda M Murray; Casey A Myers; Peter J Laz; Bradley S Davidson
Journal:  J Verif Valid Uncertain Quantif       Date:  2017-10-31

5.  Oscillation and reaction board techniques for estimating inertial properties of a below-knee prosthesis.

Authors:  Jeremy D Smith; Abbie E Ferris; Gary D Heise; Richard N Hinrichs; Philip E Martin
Journal:  J Vis Exp       Date:  2014-05-08       Impact factor: 1.355

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.