Literature DB >> 36109373

The transfer accuracy of digital and conventional full-arch impressions influenced by fixed orthodontic appliances: a reference aid-based in vitro study.

Maximiliane Amelie Schlenz1, Katharina Klaus2, Alexander Schmidt3, Bernd Wöstmann3, Marco Mersmann2, Sabine Ruf2, Niko Christian Bock2.   

Abstract

OBJECTIVES: The aim of this in vitro study was to investigate the influence of fixed orthodontic appliances (FOAs) on the transfer accuracy of full-arch impressions by five intraoral scanners (IOSs): CS3600, Primescan, Trios 4, Medit i500, Emerald S, and one conventional alginate impression (CAI).
MATERIALS AND METHODS: To compare the data with the actual model situation, an established reference aid-based method was applied. A test model with human teeth was used and modified for each testing group, resulting in five different settings: natural teeth (group A), metal brackets without/with wire (groups B/C), ceramic brackets without/with wire (groups D/E). A total of 300 (n = 12 × 5 × 5) scan datasets of IOSs were analyzed using a 3D software (GOM Inspect) and 60 (n = 12 × 5) plaster casts of CAI were measured with a coordinate measurement machine. The deviations between the reference aid and the impressions were determined.
RESULTS: For all groups with brackets (B to E), IOSs showed a higher transfer accuracy compared to CAI, even for long-span distances. However, some significant differences between the IOSs were observed (p < 0.05).
CONCLUSIONS: Within the limitations of this in vitro study, IOSs can be recommended for impressions with and without FOAs, even if CAI showed the smallest average deviations in settings without FOAs. CLINICAL RELEVANCE: IOSs are widely used in orthodontics and the current study demonstrated that their use enables fast impression taking even in settings with fixed orthodontic appliances. In addition, for these settings, the transfer accuracy is higher than with conventional alginate impressions. Nevertheless, a re-investigation in a clinical setting should be performed to verify the current in vitro findings.
© 2022. The Author(s).

Entities:  

Keywords:  Accuracy; Digital dentistry; Fixed orthodontic appliance; Full-arch impression; Intraoral scanner; Precision; Trueness

Year:  2022        PMID: 36109373     DOI: 10.1007/s00784-022-04721-5

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.606


  25 in total

1.  Accuracy and reproducibility of measurements on plaster models and digital models created using an intraoral scanner.

Authors:  Leonardo Tavares Camardella; Hero Breuning; Oswaldo de Vasconcellos Vilella
Journal:  J Orofac Orthop       Date:  2017-01-10       Impact factor: 1.938

2.  The iTero intraoral scanner in Invisalign treatment: a two-year report.

Authors:  Francesco Garino; G Battista Garino; Tommaso Castroflorio
Journal:  J Clin Orthod       Date:  2014-02

3.  Three-dimensional mandibular regional superimposition in growing patients.

Authors:  Tung Nguyen; Lucia Cevidanes; Lorenzo Franchi; Antonio Ruellas; Tate Jackson
Journal:  Am J Orthod Dentofacial Orthop       Date:  2018-05       Impact factor: 2.650

4.  Digital versus conventional impression method in children: Comfort, preference and time.

Authors:  Hakan Yilmaz; Merve Nur Aydin
Journal:  Int J Paediatr Dent       Date:  2019-08-13       Impact factor: 3.455

5.  A comparison of patient experience, chair-side time, accuracy of dental arch measurements and costs of acquisition of dental models.

Authors:  Olja Glisic; Louise Hoejbjerre; Liselotte Sonnesen
Journal:  Angle Orthod       Date:  2019-07-01       Impact factor: 2.079

Review 6.  Validity and reliability of intraoral scanners compared to conventional gypsum models measurements: a systematic review.

Authors:  Mônica L C Aragón; Luana F Pontes; Lívia M Bichara; Carlos Flores-Mir; David Normando
Journal:  Eur J Orthod       Date:  2016-06-07       Impact factor: 3.075

7.  Comparison of digital intraoral scanners and alginate impressions: Time and patient satisfaction.

Authors:  Jennifer A Burzynski; Allen R Firestone; F Michael Beck; Henry W Fields; Toru Deguchi
Journal:  Am J Orthod Dentofacial Orthop       Date:  2018-04       Impact factor: 2.650

Review 8.  Linear measurements using virtual study models.

Authors:  Nghe S Luu; Liliya G Nikolcheva; Jean-Marc Retrouvey; Carlos Flores-Mir; Tarek El-Bialy; Jason P Carey; Paul W Major
Journal:  Angle Orthod       Date:  2012-04-24       Impact factor: 2.079

Review 9.  Intraoral scanners in dentistry: a review of the current literature.

Authors:  Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo
Journal:  BMC Oral Health       Date:  2017-12-12       Impact factor: 2.757

10.  Conventional Vs Digital Impressions: Acceptability, Treatment Comfort and Stress Among Young Orthodontic Patients.

Authors:  Alessandro Mangano; Matteo Beretta; Giuseppe Luongo; Carlo Mangano; Francesco Mangano
Journal:  Open Dent J       Date:  2018-01-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.