Literature DB >> 29492177

Conventional Vs Digital Impressions: Acceptability, Treatment Comfort and Stress Among Young Orthodontic Patients.

Alessandro Mangano1, Matteo Beretta2, Giuseppe Luongo3, Carlo Mangano4, Francesco Mangano5.   

Abstract

OBJECTIVE: The objective of the present study was to compare patients' acceptability, comfort and stress with conventional and digital impressions.
MATERIALS AND METHODS: Thirty young orthodontic patients (15 males and 15 females) who had no previous experience of impressions were enrolled in this study. Conventional impressions for orthodontic study models of the dental arches were taken using an alginate impression material (Hydrogum®, Zhermack Spa, Badia Polesine, Rovigo, Italy). Fifteen days later, digital impressions of both arches were acquired using an intraoral scanner (CS3600®, Carestream Dental, Rochester, NY, USA). Immediately after impression taking, patients' acceptability, comfort and stress were measured using two questionnaires and the State anxiety scale.
RESULTS: Data showed no difference in terms of anxiety and stress; however, patients preferred the use of digital impressions systems instead of conventional impression techniques. Alginate impressions resulted as fast as digital impressions.
CONCLUSIONS: Digital impressions resulted the most accepted and comfortable impression technique in young orthodontic patients, when compared to conventional techniques.

Entities:  

Keywords:  Alginate impressions; Comfortable impression technique; Digital impressions; Intraoral scanners; Patients’ preferences; Treatment comfort

Year:  2018        PMID: 29492177      PMCID: PMC5815028          DOI: 10.2174/1874210601812010118

Source DB:  PubMed          Journal:  Open Dent J        ISSN: 1874-2106


INTRODUCTION

A pronounced gag reflex may be a potential problem for the acceptance and delivery of dental treatments. Even if there is the availability of a range of management strategies, even simple dental procedures are not accepted by some patients. Gagging problems are not uncommon in daily dental practice and the exact prevalence is unknown. This can have an important impact on treatment plan and dental treatment outcome [1]. The use of intraoral scanners for study models has increased dramatically among orthodontists. Digital scanners are capable to obtain high quality impressions and to reduce several problems like the gag reflex [2]. Intraoral scanning systems were introduced in dentistry in the mid 1980s. It was forecasted that the major part of the dentists in the U.S. and Europe would be using intraoral scanners for taking impressions in the next decades [3]. Digital impressions can offer a variety of advantages such as reduced patient discomfort, time-efficiency, simplified clinical procedures, and ability of capturing and storing highly accurate information (the 3D virtual models of patients) without pouring stone casts. The possibility of avoiding pouring stone casts can save space and time in the clinic. Further advantages of the digital impressions and scanning systems are the possibility to easily transfer digital data to the dental technician, via email, avoiding impression shipping to the laboratory: this results in a better communication with the laboratory [4]. The dental technician can immediately visualize tooth preparations (or the position of implant scanbodies), and this guarantees a better communication. Digital dentistry is transforming the relationship between dentist and dental laboratory. As a part of this trend, intraoral scanners are playing a pivotal role to this changing relationship [5]. In the last few years, several studies have dealt with IOS and their use in different fields of dentistry [6, 7]. However, only a few studies have compared the patient preference and comfort with digital and conventional impressions [6-8] in particular among young patients [8]. Hence, the aim of the present study was to evaluate the patients’ preferences and attitudes towards the digital impression technique compared to the conventional impression technique, in young orthodontic patients. The null hypothesis was that there is no difference in patients’ preference and treatment comfort between the conventional and digital impression techniques.

MATERIALS AND METHODS

Study Design, Sample and Clinical Scenario

The study population consisted of 30 subjects (15 males and 15 females) referring to one private practice (Studio Odontoiatrico Mangano, Gravedona, Como, Italy). The age ranged from 7 to 16 years (mean age 11 years ± 4 months). The subjects had no previous experience of conventional or digital impressions. The subjects and parents or legal representative were informed about the clinical procedures and of possible risks and benefits, a signed consent form was obtained for all patients. All the subjects underwent impression taking in order to obtain orthodontic study models. The inclusion and exclusion criteria are summarized in Table . The study protocol was conducted in accordance with the Helsinki Declaration of 1975, as revised in 2007. A priori sample size calculation was performed with α = 0.05 and a power set at 80%.

Conventional Impressions

The proper tray for maxillary and mandibular arches was selected by one operator (FM). The conventional impressions of both arches were made using an alginate impression material (Hydrogum, Zhermack Spa, Badia Polesine, Rovigo, Italy). The impression material was prepared according to manufacturer’s instructions and recommendations. The acceptability and perceptions of subjects were recorded immediately after the procedure using a standardized questionnaire. Patients’ attitude and discomfort was tested immediately after the impression using a VAS (Visual analogue scale). The perceived source of stress was assessed using a State anxiety scale.

Digital Impressions

A digital impression of both arches (Figs. and ) was obtained 15 days after the conventional impressions appointment. The digital impressions were performed using an intraoral scanner (CS3600®, Carestream, Rochester, NY, USA). The digital data of both arches were recorded according to manufacturer’s instructions by the same operator (FM). The acceptability and perceptions of subjects were recorded immediately after the procedure using a standardized questionnaire. Patients’ attitude and discomfort was tested immediately after the impression using a VAS (Visual Analogue Scale). The perceived source of stress was assessed using a State anxiety scale (S-scale).

Statistical Analysis

The acceptability and perceptions of the subjects on both impression techniques were assessed with a self-administrated questionnaire using a Visual Analog Scale (VAS) ranging from 0 to 100. The data were analyzed statistically applying the Wilcoxon Signed-Rank Test, the level for statistical significance was set at p = 0.05, using the SPSS 15.0 statistical software (SPSS Inc., Chicago, IL, USA). The subjects’ preferences for the impression techniques were assessed with a 9-item comparative questionnaire [7]. Descriptive statistical analysis using the SPSS 15.0 statistical software (SPSS Inc., Chicago, IL, USA) was used to evaluate the distribution of the answers. The perceived source of stress was evaluated using a State anxiety scale and statistically analyzed by Wilcoxon Signed-Rank Test (p=0.05).

RESULTS

Patients’ Acceptability and Perceptions

The evaluation scores of acceptability and perceptions by the patients are summarized in Table . The subjects’ level of stress was evaluated by State anxiety scale. The mean scores of this test were not significant (p>0.05). The mean scores of the subjects perceptions criteria were significantly different (p<0.001) except for overall time impression. The conventional impression technique resulted to be slighlty faster in terms of time. The digital impression technique was the most accepted by patients and all subjects preferred this technique (p<0.001). The 9-item questionnaire scores are summarized in Table .

DISCUSSION

In this clinical trial, according to the clinical scenario developed, the digital impression technique was more accepted by patients in terms of comfort and overall acceptance. Thus, the null hypothesis was rejected. The study sample obtained was standardized and homogenized by including subjects who had no previous experience with any kind impression techniques. To investigate the acceptance and stress perceived by the patients, homogenizing the study population is a wide-accepted clinical research method in order to optimize objectivity and minimize bias. This approach is important when it comes to objectively report patients’ acceptance avoiding report of bias of patients who had previous experience with the dental impression techniques. In this present clinical trial we mainly focused in evaluating the stress perceptions and overall procedure acceptability of two impression techniques. The results showed how statistically significant differences were found in overall time impression. This can be attributable to the fast setting time of the alginate material [9]. In terms of patients’ acceptability and comfort all the parameters investigated resulted to be statistically significant when comparing the use of digital impression systems to conventional impression techniques. These findings are in contrast with those of Grünheid et al. [2], who observed that patients preferred the conventional impression technique because of dimension of scanner’s tip. This problem has been overcome thanks to the even more narrow dimensions of intraoral scanners’ wands [10]. Our results showed that the 100% of the sample preferred the digital impression. This can be attributable to a thinner scan design [11]. Two recent trials [7, 12] showed the same trend of patients’ preference reporting that intraoral scanner are more accepted than traditional impression techniques. One of the limitations of this study is that we analyzed only one intraoral scanner system, other digital systems and their workflows could lead to different results. Therefore, it cannot be generalized that all digital impression systems are capable to give the same results. Our data revealed that there were statistically significant differences both in gag reflex and breathing difficulty. Gagging problems are encountered in daily dental practice [13]. The occurrence of nausea, while performing dental procedures is a major problem to providing good-quality dental treatment, especially when it is necessary to take impressions of the dental arches [14]. Moreover, the treatment plan could be compromised and limited by the need to limit the impact of the gag reflex. Furthermore, some patients may require more invasive levels of intervention such as anesthesia (local or general) or conscious sedation [14]. Data about the exact prevalence of the gag reflex in the general population are not available, but it undoubtedly affects many patients [15]. According to our data it can be assumed that IOS systems could easily overcome these problems. To the authors’ knowledge, this is the second clinical trial involving adolescents in evaluating acceptability of digital impression technique. In fact, in a previous similar study, Burhardt et al. [8] Assessed preferences for impression techniques in young orthodontic patients receiving alginate and two different digital impressions. In total, the authors selected 38 subjects (aged between 10 - 17 years) requiring impressions for orthodontic treatment: these were randomly allocated to three groups, that differed in the order that an alginate impressions and two different intraoral scanning procedures (Omnicam, Sirona and Lava COS, 3M) were administered [8]. After each procedure, the patients were asked to score their perceptions on a 5-point Likert scale for gag reflex, queasiness, difficulty to breathe, uncomfortable feeling, perception of the scanning time, state of anxiety, and use of a powder, and to select the preferred impression system [8]. Chairside time was also registered. More queasiness (P = 0.00) and discomfort (P = 0.02) during alginate impression taking of the maxilla were perceived compared with the scans with the Omnicam [8]. There were no significant differences in perceptions between the alginate impressions and the Lava COS and between the two scanners. Chairside times for the alginate impressions (9.7 ± 1.8 minutes) and the Omnicam (10.7 ± 1.8 minutes) were significantly lower (P <0.001) than for the Lava COS (17.8 ± 4.0 minutes). Digital impressions were favored by 51% of the subjects, whereas 29% chose alginate impressions, and 20% had no preference. Regardless of the significant differences in the registered times among the 3 impression-taking methods, the distributions of the Likert scores of time perception and maximal mouth opening were similar in all three groups [8]. The authors therefore concluded that young orthodontic patients preferred the digital impression techniques over the alginate method, although alginate impressions required the shortest chairside time [8]. Considering the limited number of studies available in the present literature, still it is not possible to state if there are age-related differences in patients’ acceptability and stress with different kind of impressions. Further studies should analyze whether or not there could be age-related differences among patients’ perceptions. However, our data showed that digital impression technique resulted to be more patient-friendly than the conventional impression technique. Further studies with wider sample and comparing different age groups should be performed in order to deeply investigate those aspects.

CONCLUSION

Within the limits of the present investigation, the following conclusions can be drawn: - The overall patients’ acceptance of digital impression techniques was significantly higher than that of conventional impression techniques; - Intraoral scanner scored a better value in terms of comfort, gag reflex and breathing difficulty; - No significant differences were found between the two techniques in terms of stress (State anxiety scale). - Alginate impressions resulted to be slightly faster than digital impressions.
Table 1

Inclusion and exclusion criteria.

Inclusion Criteria Exclusion Criteria
Good oral healthPrevious experiences with impressions
Good oral hygieneHistory of orthodontic treatments
No periodontal diseasePresence of prosthetic restorations
Table 2

Patients’ acceptability, feelings and stress perceived. *p<0.05.

Evaluation (VAS) Conventional (Mean±SD) Digital (Mean±SD) P-value
Overall discomfort52,50±9,2690,50±6,20<0,001*
Overall time impression51,40±8,6576,50±9,39<0,001*
Smell/Voice55,83±8,3175,63±22,21<0,001*
Taste/Heat54,67±7,7689,00±7,24<0,001*
GAG reflex46,33±7,6490,00±6,29<0,001*
Discomfort during mouth was open41,67±7,6986,83±7,36<0,001*
TMJ discomfort44,50±7,5888,00±7,83<0,001*
Breathing impairment45,50±8,2387,50±10,23<0,001*
Teeth and periodontal sensitivity58,33±8,4491,17±6,90<0,001*
Total evaluation score477,50±36,80775,13±43,01<0,001*
Level of Source of Stress
Score of S-scale24,67±11,3621,00±10,61>0,05
Table 3

Patients’ preferences about impression techniques.

PreferencesConventionalDigital
Which impression technique do you prefer in case of one more time for impression procedure?0%100%
Which impression technique is more comfortable from point of comparison of two impression procedure?0%100%
Which impression technique do you suggest in case of a friends’ need for impression making?0%100%
Which impression technique do you prefer from point of time involved with impression procedure?0%100%
Which impression technique do you prefer from point of feeling taste/smell or voice/heat during impression procedure?0%100%
Which impression technique do you prefer from point of the size of the intraoral scanner/impression tray used in your mouth during impression procedure?0%100%
Which impression technique do you prefer from point of having tooth/gingival sensitivity during impression procedure?0%100%
Which impression technique do you prefer from point of having difficulty in breathing during impression procedure?0%100%
Which impression technique do you prefer from point of having gagging reflex during impression procedure?0%100%
  15 in total

1.  Full 3-dimensional digital workflow for multicomponent dental appliances: A proof of concept.

Authors:  W Joerd van der Meer; Arjan Vissink; Yijin Ren
Journal:  J Am Dent Assoc       Date:  2016-02-05       Impact factor: 3.634

2.  Accuracy in tooth positioning with a fully customized lingual orthodontic appliance.

Authors:  Dan Grauer; William R Proffit
Journal:  Am J Orthod Dentofacial Orthop       Date:  2011-09       Impact factor: 2.650

3.  Influence of scanning strategies on the accuracy of digital intraoral scanning systems.

Authors:  A Ender; A Mehl
Journal:  Int J Comput Dent       Date:  2013       Impact factor: 1.883

4.  Treatment comfort, time perception, and preference for conventional and digital impression techniques: A comparative study in young patients.

Authors:  Lukasz Burhardt; Christos Livas; Wouter Kerdijk; Wicher Joerd van der Meer; Yijin Ren
Journal:  Am J Orthod Dentofacial Orthop       Date:  2016-08       Impact factor: 2.650

5.  Time-Efficiency Analysis Comparing Digital and Conventional Workflows for Implant Crowns: A Prospective Clinical Crossover Trial.

Authors:  Tim Joda; Urs Brägger
Journal:  Int J Oral Maxillofac Implants       Date:  2015 Sep-Oct       Impact factor: 2.804

6.  Clinical use of a direct chairside oral scanner: an assessment of accuracy, time, and patient acceptance.

Authors:  Thorsten Grünheid; Shawn D McCarthy; Brent E Larson
Journal:  Am J Orthod Dentofacial Orthop       Date:  2014-10-28       Impact factor: 2.650

Review 7.  A review of gagging problems in dentistry: I. Aetiology and classification.

Authors:  C M Dickinson; J Fiske
Journal:  Dent Update       Date:  2005 Jan-Feb

8.  Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study.

Authors:  Mario Imburgia; Silvia Logozzo; Uli Hauschild; Giovanni Veronesi; Carlo Mangano; Francesco Guido Mangano
Journal:  BMC Oral Health       Date:  2017-06-02       Impact factor: 2.757

9.  Comparison of digital and conventional impression techniques: evaluation of patients' perception, treatment comfort, effectiveness and clinical outcomes.

Authors:  Emir Yuzbasioglu; Hanefi Kurt; Rana Turunc; Halenur Bilir
Journal:  BMC Oral Health       Date:  2014-01-30       Impact factor: 2.757

10.  Trueness and Precision of Four Intraoral Scanners in Oral Implantology: A Comparative in Vitro Study.

Authors:  Francesco G Mangano; Giovanni Veronesi; Uli Hauschild; Eitan Mijiritsky; Carlo Mangano
Journal:  PLoS One       Date:  2016-09-29       Impact factor: 3.240

View more
  15 in total

1.  The transfer accuracy of digital and conventional full-arch impressions influenced by fixed orthodontic appliances: a reference aid-based in vitro study.

Authors:  Maximiliane Amelie Schlenz; Katharina Klaus; Alexander Schmidt; Bernd Wöstmann; Marco Mersmann; Sabine Ruf; Niko Christian Bock
Journal:  Clin Oral Investig       Date:  2022-09-15       Impact factor: 3.606

2.  Accuracy of commercial intraoral scanners.

Authors:  Mattia Sacher; Georg Schulz; Hans Deyhle; Kurt Jäger; Bert Müller
Journal:  J Med Imaging (Bellingham)       Date:  2021-05-24

3.  An Updated Comparison of Current Impression Techniques Regarding Time, Comfort, Anxiety, and Preference: A Randomized Crossover Trial.

Authors:  Hakan Yilmaz; Fatma Asli Konca; Merve Nur Aydin
Journal:  Turk J Orthod       Date:  2021-12

4.  Guidelines of Revised Orthodontic Practices for Establishing "New Normality" Post COVID-19 Pandemic.

Authors:  Abinaya Somaskandhan; Vijay Kumar Neelam Manohar; Devaki Vijayalakshmi
Journal:  Turk J Orthod       Date:  2021-12

5.  Accuracy of Implant Casts Generated with Conventional and Digital Impressions-An In Vitro Study.

Authors:  Paulo Ribeiro; Mariano Herrero-Climent; Carmen Díaz-Castro; José Vicente Ríos-Santos; Roberto Padrós; Javier Gil Mur; Carlos Falcão
Journal:  Int J Environ Res Public Health       Date:  2018-07-27       Impact factor: 3.390

6.  A Novel Full-Digital Protocol (SCAN-PLAN-MAKE-DONE®) for the Design and Fabrication of Implant-Supported Monolithic Translucent Zirconia Crowns Cemented on Customized Hybrid Abutments: A Retrospective Clinical Study on 25 Patients.

Authors:  Francesco Mangano; Bidzina Margiani; Oleg Admakin
Journal:  Int J Environ Res Public Health       Date:  2019-01-24       Impact factor: 3.390

7.  Conventional versus Digital Impressions for Full Arch Screw-Retained Maxillary Rehabilitations: A Randomized Clinical Trial.

Authors:  Paolo Cappare; Gianpaolo Sannino; Margherita Minoli; Pietro Montemezzi; Francesco Ferrini
Journal:  Int J Environ Res Public Health       Date:  2019-03-07       Impact factor: 3.390

8.  Combining Intraoral and Face Scans for the Design and Fabrication of Computer-Assisted Design/Computer-Assisted Manufacturing (CAD/CAM) Polyether-Ether-Ketone (PEEK) Implant-Supported Bars for Maxillary Overdentures.

Authors:  Francesco Mangano; Carlo Mangano; Bidzina Margiani; Oleg Admakin
Journal:  Scanning       Date:  2019-08-22       Impact factor: 1.932

9.  Technical note on introducing a digital workflow for newborns with craniofacial anomalies based on intraoral scans - part II: 3D printed Tübingen palatal plate prototype for newborns with Robin sequence.

Authors:  A B Xepapadeas; C Weise; K Frank; S Spintzyk; C F Poets; C Wiechers; J Arand; B Koos
Journal:  BMC Oral Health       Date:  2020-06-16       Impact factor: 2.757

10.  Full-Digital Workflow for Fabricating a Custom-Made Direct Metal Laser Sintering (DMLS) Mandibular Implant: A Case Report.

Authors:  Francesco Grecchi; Piero Antonio Zecca; Aldo Macchi; Alessandro Mangano; Federica Riva; Emma Grecchi; Carlo Mangano
Journal:  Int J Environ Res Public Health       Date:  2020-04-14       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.