Reliability of Time Domain AS-OCT in Measuring the Extraocular Rectus Muscle Insertion-Limbus Distances: A Systematic Review and Meta-Analysis.

Eric J Kim1,2, Arjun Ganga1, Viren K Rana1, Joshua R Tanzer1, Yasmyne C Ronquillo2, Majid Moshirfar2,3,4.   

Abstract

Purpose: The insertion-limbus distances of the extraocular muscles are clinically relevant in the preoperative planning of strabismus surgeries, especially in reoperations when information regarding insertion sites is not accessible to the surgeon. In this systematic review, we assess the reliability of time-domain anterior segment optical coherence tomography (TD AS-OCT) in determining insertion-limbus distances preoperatively by investigating prior studies that compare preoperative TD AS-OCT measurements of the insertion-limbus distances to those of calipers, which are assumed to be the gold standard.
Methods: Systematically reviewing EMBASE, PubMed, Google Scholar, Science Direct, and Web of Science, 2 members screened for studies that compared preoperative TD AS-OCT measurements to those of intraoperative calipers, the gold standard. To assess the risk of bias for individual studies, the reviewers utilized the ROBINS-I tool, a Cochrane's collaboration tool used to assess bias in studies that are not randomized. For the meta-analysis, parallel forms reliability was examined and estimated as the Pearson product-moment correlation between TD AS-OCT measurements and surgical caliper measurements.
Results: Six out of the seven eligible studies provided measures of reliability that were >0.7. These six records were eligible for meta-analysis. There was no evidence of a difference between means of TD AS-OCT and caliper measurements ( = 6.81, 95% CI [6.41, 7.22]; = 6.73, 95% CI [6.18, 7.29]; = 0.08, 95% CI [-0.44, 0.61]). Reliability was estimated to be good ( = 0.91) though the lower limit was slightly below the recommended minimum acceptable level of 0.70 (95% CI [0.65, >0.99]).
Conclusion: In the setting of primary surgeries, TD AS-OCT has an acceptable reliability. However, there is insufficient data to conclude whether TD AS-OCT has an acceptable reliability in the setting of reoperations.
© 2022 Kim et al.

Entities:  

Keywords:  extraocular rectus muscle; limbus; reliability; strabismus; time domain AS-OCT; validity

Year:  2022        PMID: 36046574      PMCID: PMC9423110          DOI: 10.2147/OPTH.S381644

Source DB:  PubMed          Journal:  Clin Ophthalmol        ISSN: 1177-5467


  19 in total

1.  Localising rectus muscle insertions using high frequency wide-field ultrasound biomicroscopy.

Authors:  Hayat Ahmad Khan; David R Smith; Stephen P Kraft
Journal:  Br J Ophthalmol       Date:  2012-01-04       Impact factor: 4.638

2.  Ultrasound biomicroscopy in strabismus reoperations.

Authors:  Shuan Dai; Stephen P Kraft; David R Smith; J Raymond Buncic
Journal:  J AAPOS       Date:  2006-06       Impact factor: 1.220

3.  Combination of anterior segment optical coherence tomography modalities to improve accuracy of rectus muscle insertion location.

Authors:  Michael J Venincasa; Carla J Osigian; Kara M Cavuoto; Julia D Rossetto; Hilda Capo
Journal:  J AAPOS       Date:  2017-05-17       Impact factor: 1.220

4.  Reproducibility of horizontal extraocular muscle insertion distance in anterior segment optical coherence tomography and the effect of head position.

Authors:  Kyung-Ah Park; Ju Yeon Lee; Sei Yeul Oh
Journal:  J AAPOS       Date:  2014-02       Impact factor: 1.220

5.  The accuracy of wide-field ultrasound biomicroscopy in localizing extraocular rectus muscle insertions in strabismus reoperations.

Authors:  Arash Mirmohammadsadeghi; Vahideh Manuchehri; Mohammad Reza Akbari
Journal:  J AAPOS       Date:  2017-10-13       Impact factor: 1.220

6.  The accuracy of anterior segment optical coherence tomography (AS-OCT) in localizing extraocular rectus muscles insertions.

Authors:  Cheryl S Ngo; David Smith; Stephen P Kraft
Journal:  J AAPOS       Date:  2015-06       Impact factor: 1.220

7.  Accuracy of Optical Coherence Tomography Measurements of Rectus Muscle Insertions in Adult Patients Undergoing Strabismus Surgery.

Authors:  Julia D Rossetto; Kara M Cavuoto; Norma Allemann; Craig A McKeown; Hilda Capó
Journal:  Am J Ophthalmol       Date:  2017-02-03       Impact factor: 5.258

8.  Limbus-insertion distance of superior rectus in primary angle closure glaucoma: an anterior segment OCT study.

Authors:  Wenbin Huang; Xinbo Gao; Xinyu Zhang; Xiulan Zhang
Journal:  Can J Ophthalmol       Date:  2016-10-01       Impact factor: 1.882

9.  Rates of Reoperation and Abnormal Binocularity Following Strabismus Surgery in Children.

Authors:  Christopher T Leffler; Kamyar Vaziri; Stephen G Schwartz; Kara M Cavuoto; Craig A McKeown; Krishna S Kishor; Adam C Janot
Journal:  Am J Ophthalmol       Date:  2015-11-05       Impact factor: 5.258

10.  The PRISMA 2020 statement: an updated guideline for reporting systematic reviews.

Authors:  Matthew J Page; Joanne E McKenzie; Patrick M Bossuyt; Isabelle Boutron; Tammy C Hoffmann; Cynthia D Mulrow; Larissa Shamseer; Jennifer M Tetzlaff; Elie A Akl; Sue E Brennan; Roger Chou; Julie Glanville; Jeremy M Grimshaw; Asbjørn Hróbjartsson; Manoj M Lalu; Tianjing Li; Elizabeth W Loder; Evan Mayo-Wilson; Steve McDonald; Luke A McGuinness; Lesley A Stewart; James Thomas; Andrea C Tricco; Vivian A Welch; Penny Whiting; David Moher
Journal:  Syst Rev       Date:  2021-03-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.