Literature DB >> 24568976

Reproducibility of horizontal extraocular muscle insertion distance in anterior segment optical coherence tomography and the effect of head position.

Kyung-Ah Park1, Ju Yeon Lee1, Sei Yeul Oh2.   

Abstract

PURPOSE: To investigate the reproducibility of horizontal extraocular muscle insertion distance measurements in anterior segment optical coherence tomography (AS-OCT) and to evaluate the effect of eye position on the measurement.
METHODS: The right eyes of 30 healthy young subjects underwent AS-OCT. Varying eye positions were used and the muscle insertion distance was measured by two independent examiners who each measured the insertion distance twice. The measurement was performed for the lateral rectus and medial rectus muscles with the eye rotated 40°, 50°, and 60° to the midline of the instrument. Reproducibility was evaluated with the intraclass correlation coefficient (ICC) and Bland-Altman plot.
RESULTS: The lateral rectus insertion distance was smallest with 50° rotation and the medial rectus insertion distance did not show a consistent pattern in regards to gaze position. The differences in insertion distance between different eye positions were not statistically significant for both muscles. The inter- and intraexaminer ICC reproducibility values were excellent for both lateral and medial rectus insertion distance measurements.
CONCLUSIONS: Inter- and intraexaminer reproducibility were excellent for lateral and medial rectus muscle insertion distance measurements using AS-OCT. The measurements tended to be smallest with the 50° position in lateral rectus measurement; however, medial rectus measurements were variable.
Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24568976     DOI: 10.1016/j.jaapos.2013.11.005

Source DB:  PubMed          Journal:  J AAPOS        ISSN: 1091-8531            Impact factor:   1.220


  11 in total

1.  Identification and biometry of horizontal extraocular muscle tendons using optical coherence tomography.

Authors:  Guillermo Salcedo-Villanueva; Miguel Paciuc-Beja; Mariana Harasawa; Raul Velez-Montoya; Jeffrey L Olson; Scott C Oliver; Naresh Mandava; Hugo Quiroz-Mercado
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-12-03       Impact factor: 3.117

2.  Postoperative change in lateral rectus muscle insertion measured by anterior segment optical coherence tomography.

Authors:  J-Y Lee; K-A Park; I J Lyu; S Y Oh
Journal:  Eye (Lond)       Date:  2017-06-16       Impact factor: 3.775

3.  Changes in conjunctival-scleral thickness after strabismus surgery measured with anterior segment optical coherence tomography.

Authors:  Hiroko Suzuki; Akiko Hikoya; Miwa Komori; Risako Inagaki; Takashi Haseoka; Shinji Arai; Yuri Takagi; Yoshihiro Hotta; Miho Sato
Journal:  Jpn J Ophthalmol       Date:  2018-07-06       Impact factor: 2.447

4.  Anterior segment optical coherence tomography for identifying muscle status in strabismus surgery.

Authors:  Brijesh Takkar; Pradeep Sharma; Ashutosh Kumar Singh; Pranita Sahay
Journal:  Int J Ophthalmol       Date:  2016-06-18       Impact factor: 1.779

Review 5.  Reliability of Time Domain AS-OCT in Measuring the Extraocular Rectus Muscle Insertion-Limbus Distances: A Systematic Review and Meta-Analysis.

Authors:  Eric J Kim; Arjun Ganga; Viren K Rana; Joshua R Tanzer; Yasmyne C Ronquillo; Majid Moshirfar
Journal:  Clin Ophthalmol       Date:  2022-08-25

6.  Horizontal Extraocular Muscle Insertion Site in Relation to Axial Length Using Swept-Source Anterior Segment OCT.

Authors:  Dina El-Fayoumi; Nermeen Bahgat; Mohamed Khafagy; Ragai Hatata; Dalia Sabry; Ghada Allam; Manal Ali Kasem; Sherin Sadek
Journal:  Clin Ophthalmol       Date:  2020-10-29

7.  Anterior eye tissue morphology: Scleral and conjunctival thickness in children and young adults.

Authors:  Scott A Read; David Alonso-Caneiro; Stephen J Vincent; Alexander Bremner; Annabel Fothergill; Brittney Ismail; Rebecca McGraw; Charlotte J Quirk; Elspeth Wrigley
Journal:  Sci Rep       Date:  2016-09-20       Impact factor: 4.379

8.  Horizontal Extraocular Muscle and Scleral Anatomy in Children: A Swept-Source Anterior Segment Optical Coherence Tomography Study.

Authors:  Jung Yeob Han; Dong Cheol Lee; Se Youp Lee
Journal:  Korean J Ophthalmol       Date:  2018-03-19

9.  Pre-, Intra-, and Post-Operative Evaluation of Extraocular Muscle Insertions Using Optical Coherence Tomography: A Comparison of Four Devices.

Authors:  Matthew S Pihlblad; Andrew Troia; Sapna Tibrewal; Parth R Shah
Journal:  J Clin Med       Date:  2019-10-19       Impact factor: 4.241

10.  Shape analysis of rectus extraocular muscles with age and axial length using anterior segment optical coherence tomography.

Authors:  Kiyo Shibata; Atsushi Fujiwara; Ichiro Hamasaki; Takehiro Shimizu; Reika Kono; Keisuke Kanenaga; Masanori Nakazawa; Yuki Morizane
Journal:  PLoS One       Date:  2020-12-23       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.