Mahmud Ahmednur1, Hanan Awel1, Gutama Haile1.
Abstract
Indoor air quality determines the well-being of occupants. It has been linked to sick building syndrome and building-related diseases which lead to many socio-economic problems including reduced productivity and impaired learning. Indoor air quality problem is more serious for prisoners, due to their confinement and exposure condition. However, it has not been studied in our study setting. Thus, this study aimed to determine the indoor air microbial quality and associated factors in Jimma town prison administration, Southwestern Ethiopia. A cross-sectional study design was employed in August 2021. Data on the general condition of the prison rooms and occupancy were collected by trained data collectors using an observational checklist. The microbial sample was collected using a sterilized Petri dish. A total of 19 triplicate air samples were collected using Mannitol salt agar and Sabouroad dextrose agar media for the growth of S. aureus and fungi respectively. Data were analyzed using SPSS version 23 and presented using tables and a graph. The effect of predictor variables on the microbial load was also analyzed by using linear regression. The finding of this study revealed that the microbial load of indoor air at Jimma town prison administration ranged from 891 to 15 439 and 315 to 3067 CFU/m³ for S. aureus and fungi respectively. Both S. aureus and the fungal load of the indoor environment were positively affected by the temperature of the room. Whereas, the floor space per inmate affects the concentration of S. aureus alone. Almost all rooms of the prison administration had microbial load beyond the acceptable limit. Higher temperature, less floor space per inmate, bad floor cleanness conditions, inadequate ventilation, and dampness were contributing factors to the high load of S. aureus and fungus. Thus, additional rooms are required to reduce overcrowding and keep room temperature.Entities:
Keywords: Prison health; S. aureus; fungi; indoor air quality; inmate; microbial load
Year: 2022 PMID: 36003416 PMCID: PMC9393662 DOI: 10.1177/11786302221118842
Source DB: PubMed Journal: Environ Health Insights ISSN: 1178-6302
Frequency distribution of room condition variables in Jimma town prison administration, 2021 (N = 19).
| Variable (prison house) | Category | Frequency | Percent |
|---|---|---|---|
| Wall type | Mud | 2 | 10.5 |
| Stone | 17 | 89.5 | |
| Floor-type | Mud | 2 | 10.5 |
| Stone | 14 | 73.7 | |
| Tiles | 3 | 15.8 | |
| Ceiling type | Cloth | 2 | 10.5 |
| Wood | 17 | 89.5 | |
| Cleanness condition of the floor | Bad | 15 | 78.9 |
| Good | 4 | 21.1 | |
| Condition of ventilation | Adequate | 9 | 47.4 |
| Inadequate | 10 | 52.6 | |
| Lighting condition | Adequate | 7 | 36.8 |
| Inadequate | 12 | 63.2 | |
| Presence of dampness | Yes | 15 | 78.95 |
| No | 4 | 21.05 |
The minimum, maximum, mean, and standard deviation of some determining room conditions and microbial load of indoor air in Jimma town prison administration, 2021 (N = 19).
| Variable | Minimum | Maximum | Mean | Standard deviation |
|---|---|---|---|---|
| Number of open windows per room during the study | 1.0 | 5.0 | 4.263 | 4.2275 |
| Number of occupants per room | 10 | 155 | 99.05 | 57.814 |
| Area of the room (m²) | 24 | 100 | 79.16 | 29.540 |
| Floor space per inmate (m²/person) | 0.65 | 2.4 | 1.06 | 0.53688 |
| Temperature (°C) of the room | 27.5 | 32.5 | 29.779 | 1.6054 |
| 68 | 1178 | 540.32 | 344.778 | |
| 891 | 15 439 | 7081.32 | 4518.784 | |
| Fungal count/plate | 24 | 234 | 92.21 | 57.815 |
| Fungal load (CFU/m³) | 315 | 3067 | 1084.21 | 680.064 |
Total count and load in colony-forming unit per cubic meter of S. aureus and fungus in the respected rooms of Jimma town prison administration, 2021 (N = 19).
| Room number | Fungal count/plate | Fungal load (CFU/m³) | ||
|---|---|---|---|---|
| 1 | 780 | 10 223 | 108 | 1415 |
| 2 | 520 | 6815 | 94 | 1232 |
| 3 | 552 | 7234 | 97 | 1271 |
| 4 | 586 | 7680 | 99 | 1297 |
| 5 | 1120 | 14 679 | 122 | 1599 |
| 6 | 568 | 7444 | 102 | 1337 |
| 7 | 912 | 11 953 | 116 | 1520 |
| 8 | 706 | 9253 | 105 | 1376 |
| 9 | 660 | 8650 | 100 | 1311 |
| 10 | 1178 | 15 439 | 234 | 3067 |
| 11 | 320 | 4192 | 58 | 760 |
| 12 | 370 | 4849 | 61 | 799 |
| 13 | 981 | 12 857 | 226 | 2962 |
| 14 | 282 | 3696 | 44 | 577 |
| 15 | 318 | 4168 | 52 | 682 |
| 16 | 68 | 891 | 24 | 315 |
| 17 | 74 | 970 | 30 | 393 |
| 18 | 141 | 1848 | 42 | 550 |
| 19 | 130 | 1704 | 38 | 498 |
Shows the correlation among the room condition variables in Jimma town prison administration, 2021 (N = 19).
| Temperature (°C) | Floor space per inmate (m²/person) | Area of the room (m²) | Number of occupants | |
|---|---|---|---|---|
| Temperature (°C) | ||||
| Pearson correlation | 1 | −.547 | .535 | .626 |
| Sig. | .015 | .018 | .004 | |
| Floor space per inmate (m²/person) | ||||
| Pearson correlation | −.547 | 1 | −.765 | −.895 |
| Sig. | .015 | .000 | .000 | |
| Area of the room (m²) | ||||
| Pearson correlation | .535 | −.765 | 1 | .922** |
| Sig. | .018 | .000 | .000 | |
| Number of occupant | ||||
| Pearson correlation | .626 | −.895 | .922 | 1 |
| Sig. | .004 | .000 | .000 | |
Correlation is significant at the .05 level. **Correlation is significant at the .01 level.
Figure 1.Scatter plots of S. aureus versus fungi concentration in Jimma town prison administration, 2021 (N = 19).
Shows the linear regressions using indoor total S. aureus load as a dependent variable.
| Model | Unstandardized coefficients | Standardized coefficients |
| Sig. | ||
|---|---|---|---|---|---|---|
|
| Standard error | Beta | ||||
| 1 | (Constant) | −33 356.693 | 15 276.048 | −2.184 | .044 | |
| Floor space per inmate (m²/person) | −3393.183 | 1442.784 | −.403 | −2.352 | .032 | |
| Temperature (°C) | 1479.278 | 482.500 | .526 | 3.066 | .007 | |
Correlation is significant at the .05 level.
Indicates the linear regressions using indoor total Fungal load as a dependent variable.
| Model | Unstandardized coefficients | Standardized coefficients |
| Sig. | ||
|---|---|---|---|---|---|---|
|
| Standard error | Beta | ||||
| 1 | (Constant) | −5186.607 | 2710.980 | −1.913 | .074 | |
| Floor space per inmate (m²/person) | −378.221 | 256.045 | −.299 | −1.477 | .159 | |
| Temperature (°C) | 224.104 | 85.627 | .529 | 2.617 | .019 | |
Correlation is significant at the .05 level.