Literature DB >> 25183103

Microbiological quality of indoor air in university libraries.

Samuel Fekadu Hayleeyesus1, Abayneh Melaku Manaye1.   

Abstract

OBJECTIVE: To evaluate the concentration of bacteria and fungi in the indoor environment of Jimma University libraries, so as to estimate the health hazard and to create standards for indoor air quality control.
METHODS: The microbial quality of indoor air of eight libraries of Jimma University was determined. The settle plate method using open Petri-dishes containing different culture media was employed to collect sample twice daily. Isolates were identified according to standard methods.
RESULTS: The concentrations of bacteria and fungi aerosols in the indoor environment of the university libraries ranged between 367-2595 CFU/m(3). According to the sanitary standards classification of European Commission, almost all the libraries indoor air of Jimma University was heavily contaminated with bacteria and fungi. In spite of their major source difference, the average fungi density found in the indoor air of libraries did appear to follow the same trend with bacterial density (P=0.001). The bacteria isolates included Micrococcus sp., Staphylococcus aureus, Streptococcus pyogenes, Bacillus sp. and Neisseria sp. while Cladosporium sp., Alternaria sp., Penicillium sp. and Aspergillus sp. were the most isolated fungi.
CONCLUSIONS: The indoor air of all libraries were in the range above highly contaminated according to European Commission classification and the most isolates are considered as potential candidates involved in the establishment of sick building syndromes and often associated with clinical manifestations like allergy, rhinitis, asthma and conjunctivitis. Thus, attention must be given to control those environmental factors which favor the growth and multiplication of microbes in indoor environment of libraries to safeguard the health of users and workers.

Entities:  

Keywords:  Bacteria; Fungi; Indoor air; Microbiological assessment; Open-plate technique; Sedimentation technique

Year:  2014        PMID: 25183103      PMCID: PMC4025286          DOI: 10.12980/APJTB.4.2014C807

Source DB:  PubMed          Journal:  Asian Pac J Trop Biomed        ISSN: 2221-1691


  9 in total

Review 1.  The roles of Penicillium and Aspergillus in sick building syndrome.

Authors:  Christopher J Schwab; David C Straus
Journal:  Adv Appl Microbiol       Date:  2004       Impact factor: 5.086

2.  Association of air-conditioning with respiratory symptoms in office workers in tropical climate.

Authors:  G S Graudenz; C H Oliveira; A Tribess; C Mendes; M R D O Latorre; J Kalil
Journal:  Indoor Air       Date:  2005-02       Impact factor: 5.770

3.  Assessment of microbiological indoor air quality in an Italian office building equipped with an HVAC system.

Authors:  Sa Bonetta; Si Bonetta; S Mosso; S Sampò; E Carraro
Journal:  Environ Monit Assess       Date:  2009-02-18       Impact factor: 2.513

4.  Indoor air particles and bioaerosols before and after renovation of moisture-damaged buildings: the effect on biological activity and microbial flora.

Authors:  Kati Huttunen; Helena Rintala; Maija-Riitta Hirvonen; Asko Vepsäläinen; Anne Hyvärinen; Teija Meklin; Mika Toivola; Aino Nevalainen
Journal:  Environ Res       Date:  2008-05-06       Impact factor: 6.498

5.  The occupant as a source of house dust bacteria.

Authors:  Martin Täubel; Helena Rintala; Miia Pitkäranta; Lars Paulin; Sirpa Laitinen; Juha Pekkanen; Anne Hyvärinen; Aino Nevalainen
Journal:  J Allergy Clin Immunol       Date:  2009-09-19       Impact factor: 10.793

6.  Metabolic activity of moulds as a factor of building materials biodegradation.

Authors:  Beata Gutarowska
Journal:  Pol J Microbiol       Date:  2010

7.  Size-resolved emission rates of airborne bacteria and fungi in an occupied classroom.

Authors:  J Qian; D Hospodsky; N Yamamoto; W W Nazaroff; J Peccia
Journal:  Indoor Air       Date:  2012-02-13       Impact factor: 5.770

8.  Human occupancy as a source of indoor airborne bacteria.

Authors:  Denina Hospodsky; Jing Qian; William W Nazaroff; Naomichi Yamamoto; Kyle Bibby; Hamid Rismani-Yazdi; Jordan Peccia
Journal:  PLoS One       Date:  2012-04-18       Impact factor: 3.240

9.  Indoor airborne bacterial communities are influenced by ventilation, occupancy, and outdoor air source.

Authors:  J F Meadow; A E Altrichter; S W Kembel; J Kline; G Mhuireach; M Moriyama; D Northcutt; T K O'Connor; A M Womack; G Z Brown; J L Green; B J M Bohannan
Journal:  Indoor Air       Date:  2013-05-24       Impact factor: 5.770

  9 in total
  11 in total

1.  Quantitative assessment of bio-aerosols contamination in indoor air of University dormitory rooms.

Authors:  Samuel Fekadu Hayleeyesus; Amanuel Ejeso; Fikirte Aklilu Derseh
Journal:  Int J Health Sci (Qassim)       Date:  2015-07

2.  An Assessment of Airborne Bacteria and Fungi in the Female Dormitory Environment: Level, Impact Factors and Dose Rate.

Authors:  Yanju Li; Xinyu Wang; Guoqing Cao; Yu Wang; Qingqing Miao; Jinlu He
Journal:  Int J Environ Res Public Health       Date:  2022-05-29       Impact factor: 4.614

3.  Environmental Factors Affecting Diversity, Structure, and Temporal Variation of Airborne Fungal Communities in a Research and Teaching Building of Tianjin University, China.

Authors:  Yixuan Lu; Xiao Wang; Lucineidy C S de S Almeida; Lorenzo Pecoraro
Journal:  J Fungi (Basel)       Date:  2022-04-22

4.  Airborne microorganisms cultivable on naturally ventilated document repositories of the National Archive of Cuba.

Authors:  Sofía Borrego; Ivette Perdomo
Journal:  Environ Sci Pollut Res Int       Date:  2015-10-24       Impact factor: 4.223

Review 5.  Monitoring biodiversity in libraries: a pilot study and perspectives for indoor air quality.

Authors:  F Valeriani; C Cianfanelli; G Gianfranceschi; S Santucci; V Romano Spica; N Mucci
Journal:  J Prev Med Hyg       Date:  2017-09

6.  Assessment of culturable airborne bacteria of indoor environments in classrooms, dormitories and dining hall at university: a case study in China.

Authors:  Yanju Li; Yanhui Ge; Chunbin Wu; Dexing Guan; Jinbao Liu; Fuyang Wang
Journal:  Aerobiologia (Bologna)       Date:  2020-03-02       Impact factor: 2.410

Review 7.  Building upon current knowledge and techniques of indoor microbiology to construct the next era of theory into microorganisms, health, and the built environment.

Authors:  Patrick F Horve; Savanna Lloyd; Gwynne A Mhuireach; Leslie Dietz; Mark Fretz; Georgia MacCrone; Kevin Van Den Wymelenberg; Suzanne L Ishaq
Journal:  J Expo Sci Environ Epidemiol       Date:  2019-07-15       Impact factor: 5.563

8.  Microbial Air Quality in Neighborhoods near Landfill Sites: Implications for Public Health.

Authors:  Stephen T Odonkor; Tahiru Mahami
Journal:  J Environ Public Health       Date:  2020-07-11

9.  Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools.

Authors:  Zewudu Andualem; Zemichael Gizaw; Laekemariam Bogale; Henok Dagne
Journal:  Multidiscip Respir Med       Date:  2019-01-22

10.  Home Assessment of Indoor Microbiome (HAIM) in Relation to Lower Respiratory Tract Infections among Under-Five Children in Ibadan, Nigeria: The Study Protocol.

Authors:  Adekunle G Fakunle; Babatunde Olusola; Nkosana Jafta; Adedayo Faneye; Dick Heederik; Lidwien A M Smit; Rajen N Naidoo
Journal:  Int J Environ Res Public Health       Date:  2020-03-13       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.