Nonlinear partial volume artifacts in x-ray computed tomography.

G H Glover, N J Pelc.   

Abstract

Dark streaks connecting the petrous bones are often observed in cranial transverse section CT reconstructions. These artifacts are usually only slightly diminished by two-pass beam hardening corrections. However, it is found that by narrowing the slice thickness the artifacts are substantially reduced. In this paper, it is shown that axial partial volume effects can account for the presence of the artifacts. These axial partial volume effects occur when, at any point in the slice, the object has axial variations in attenuation. In such cases the logarithm of the integrated intensity measured by the detector is not a linear function of the integrated attenuation (even for monochromatic beams). This nonlinearity causes inconsistencies in the data set which in turn can cause streaks in the image. We have studied the partial volume effect using computer simulation. Algorithms are presented whose purpose is to correct for these effects by estimating the axial variation using neighboring slices. These correction algorithms are successful in computer simulation cases but failed with clinical data. It is concluded that no practical correction method is viable unless overlap scanning is employed. However, thin-slice scanning for sections where these artifacts are common is perhaps a more preferable solution.

Mesh:

Year:  1980        PMID: 7393149     DOI: 10.1118/1.594678

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  26 in total

1.  Evaluation of labio-lingual bony support of lower incisors in orthodontically untreated adults with the help of computed tomography.

Authors:  K Nauert; R Berg
Journal:  J Orofac Orthop       Date:  1999       Impact factor: 1.938

2.  Accuracy of microvascular measurements obtained from micro-CT images.

Authors:  Timothy L Kline; Mair Zamir; Erik L Ritman
Journal:  Ann Biomed Eng       Date:  2010-05-11       Impact factor: 3.934

3.  Image quality of multisection CT of the brain: thickly collimated sequential scanning versus thinly collimated spiral scanning with image combining.

Authors:  M van Straten; H W Venema; C B L M Majoie; N J M Freling; C A Grimbergen; G J den Heeten
Journal:  AJNR Am J Neuroradiol       Date:  2007-03       Impact factor: 3.825

Review 4.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

5.  Correction for resolution nonuniformities caused by anode angulation in computed tomography.

Authors:  Patrick J La Rivière; Phillip Vargas
Journal:  IEEE Trans Med Imaging       Date:  2008-09       Impact factor: 10.048

6.  Relating function to branching geometry: a micro-CT study of the hepatic artery, portal vein, and biliary tree.

Authors:  Timothy L Kline; Mair Zamir; Erik L Ritman
Journal:  Cells Tissues Organs       Date:  2011-04-13       Impact factor: 2.481

7.  Multi-material decomposition using statistical image reconstruction for spectral CT.

Authors:  Yong Long; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-04-25       Impact factor: 10.048

8.  Resistive NMR of brain stem gliomas.

Authors:  R A Zimmerman; L T Bilaniuk; R Packer; L Sutton; L Samuel; M H Johnson; R I Grossman; H I Goldberg
Journal:  Neuroradiology       Date:  1985       Impact factor: 2.804

9.  Cerebral NMR: diagnostic evaluation of brain tumors by partial saturation technique with resistive NMR.

Authors:  R A Zimmerman; L T Bilaniuk; R I Grossman; H I Goldberg; W Edelstein; P Bottomley; R W Redington
Journal:  Neuroradiology       Date:  1985       Impact factor: 2.804

10.  Intracranial carotid calcification on CT images as an indicator of atheromatous plaque: analysis of high-resolution CTA images using a 64-multidetector scanner.

Authors:  Michimasa Suzuki; Yutaka Ozaki; Shinji Komura; Atsushi Nakanishi
Journal:  Radiat Med       Date:  2007-10-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.