Literature DB >> 35865032

Robot-Assisted Kyphoplasty Improves Clinical and Radiological Features Better Than Fluoroscopy-Assisted Kyphoplasty in the Treatment of Vertebral Compression Fractures: A Meta-Analysis.

Hongwei Yu1,2, Gan Luo2,3, Bin Yu2, Tianwei Sun2, Qiong Tang4, Yutao Jia2.   

Abstract

Purpose: This meta-analysis aimed to determine whether patients treated with robot-assisted kyphoplasty for vertebral compression fractures have superior clinical and radiographic improvement than those treated with fluoroscopy.
Methods: A comprehensive search of the PubMed, Embase, Cochrane Library, Science Direct, and CNKI (China National Knowledge Infrastructure) databases was conducted to find randomized control trials (RCTs) or observational cohort studies that compared robotic-assisted kyphoplasty (RA-kyphoplasty) with fluoroscopy-assisted kyphoplasty (FA-kyphoplasty) in treating vertebral compression fractures. Preoperative, postoperative, and final follow-up data on vertebral height (VH), vertebral kyphosis angle (VKA), visual analog scale (VAS) for back pain, and cement leakage rate were collected from eligible studies for meta-analysis. Patients were divided into RA and FA groups depending on whether the operation was robotically or fluoroscopically guided.
Results: We included 6 cohort studies with 491 patients and 633 vertebrae. The results of the meta-analysis showed that the RA group had a higher VH than the FA group at both postoperation (p < 0.001) and final follow-up (p < 0.001); the VKA in the RA group was lower than that in the FA group at postoperation (p < 0.001) and final follow-up (p < 0.001); the back pain VAS score was lower in the RA group than in the FA group at postoperation (p = 0.01) and final follow-up (p = 0.03); and the cement leakage rate in the RA group was lower than those in the FA group (p < 0.001).
Conclusion: This meta-analysis demonstrated that RA-kyphoplasty outperformed FA-kyphoplasty in vertebral height restoration, kyphosis angle correction, VAS score reduction for back pain, and lower cement leakage rate in the treatment of vertebral compression fractures.
Copyright © 2022 Yu, Luo, Yu, Sun, Tang and Jia.

Entities:  

Keywords:  Robotic-assisted; cement leakage rates; fluoroscopy-assisted; kyphoplasty; vertebral compression fractures; vertebral height; vertebral kyphosis angle

Year:  2022        PMID: 35865032      PMCID: PMC9296046          DOI: 10.3389/fsurg.2022.955966

Source DB:  PubMed          Journal:  Front Surg        ISSN: 2296-875X


Introduction

Kyphoplasty is commonly applied in the treatment of OVFs, with the advantages of rapid pain relief and correction of vertebral height and kyphosis (1, 2). This is essential for improving the quality of life and maintaining the sagittal balance of the spine for patients (3, 4). However, the correction of vertebral height and kyphosis with this technique is often not thorough enough to completely correct the sagittal imbalance of the spine, so that patients have to compensate for the anterior shift of the body through lumbar extension or pelvic inversion (5). This non-physiological compensation will lead to chronic persistent low back pain (6) and increase the risk of vertebral refracture (7). In addition, both surgeons and patients may be at risk for dermatitis, cataracts, and cancer due to the high radiation exposure caused by repeated fluoroscopy (8, 9). Robotic assistance enables three-dimensional planning of the K-wire's position, potentially allowing precise placement of vertebral implants. Advantages of the robot over fluoroscopic techniques also include prevention of tremors, avoidance of instability caused by manual manipulation, and further reduction of damage to the pedicle and posterior wall of the vertebral body, thereby reducing the risk of cement leakage (10, 11). This meta-analysis aimed to evaluate whether patients treated with robot-assisted kyphoplasty for vertebral compression fractures have superior clinical and radiographic improvement than patients treated with fluoroscopy-assisted kyphoplasty.

Methods

The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement (12) was used as guidance for our systematic review and meta-analysis (see Supplementary file for PRISMA checklist).The protocol for this review was registered on the International Platform of Registered Systematic Review and Meta-analysis Protocols database with the registration number INPLASY202250106 and DOI number 10.37766/inplasy2022.5.0106.

Search Strategy and Study Selection

The following databases were extensively searched: PubMed, EMBASE, ScienceDirect, the Cochrane Library, and CNKI. We identified relevant articles published up to 1 May 2022 without language limitations. Studies were found using the following keywords: “spinal robot”, “robot-assisted”, “vertebral compression fracture”, and “kyphoplasty”. Two independent investigators screened eligible studies and reviewed references of included studies to identify additional articles. A third reviewer was consulted when the two reviewers could not reach a consensus.

Selection Strategy

The inclusion and exclusion criteria of studies followed PICOS principles. (1) Participants: Patients with osteoporotic vertebral compression fractures or traumatic vertebral compression fractures (Magerl type A), who need to be treated with kyphoplasty. (2) Interventions: Kyphoplasty was performed under robotic guidance. (3) Comparisons: Kyphoplasty was performed under conventional fluoroscopic guidance (4) Outcomes: studies should include at least one of the following data: preoperative, postoperative and final follow-up vertebral height and kyphosis angle and VAS score for back pain; cement leakage rate. (5) Study design: Observational studies and randomized control trials were eligible. Case reports, case series, commentaries, practice guidelines, systematic reviews and meta analysis were excluded. In addition, duplicate studies with the same cohort or studies considered by consensus to be of low quality were excluded.

Data Extraction

Data were extracted from the included studies as follows: (1) study design: first author, publication region, publication time, and study type; (2) sample demographics: number of patients and vertebrae, follow-up time, age, sex, and disease diagnosis; (3) surgery details: robot type, operation time, X-ray exposure frequency and doses; and (4) analysis variables: preoperative, postoperative and final follow-up vertebral height and kyphosis angle and VAS score for back pain and cement leakage rate. The results could not be meta-analyzed for the operation time, radiation exposure frequency, and doses due to the significant heterogeneity among the reported outcomes across all studies.

Assessment of Risk of Bias

Two reviewers evaluated bias risk in the cohort studies using the Newcastle–Ottawa scale (13). Sensitivity analysis was performed by excluding a single study of each study in turn and reanalyzing the data. Publication bias was analyzed qualitatively by funnel plot.

Statistical Analysis

The continuous variables were estimated by weighted mean difference (WMD), and dichotomous variables were estimated by using odds ratios (ORs) with 95% confidence intervals (CIs). The statistical heterogeneity of the pooled results was determined using the I2 statistic. For this meta-analysis, we used the fixed-effect model when I2 was greater than 50%, and if I2 was less than 50%, a random-effect model was applied. The meta-analysis results were considered statistically significant when the p value was <0.05. The meta-analysis was performed using Review Manager 5.4 (Revman, The Cochrane Collaboration, Oxford, The UK).

Results

Search Results

A total of 86 articles from PubMed, EMBASE, the Cochrane Library, ScienceDirect, and CNKI were initially identified. The exact number of articles identified in each database is as follows: PubMed (n = 65), EMBASE (n = 17), ScienceDirect (n = 3), Cochrane library (n = 0), CNKI (n = 1). Twelve articles were excluded because of duplication, and 62 articles were excluded by screening the titles and abstracts individually. There remained 12 articles that underwent a comprehensive full-text analysis. Finally, 5 articles (14–18) met the inclusion and exclusion criteria. Because the article by Yuan (18) contains two cohort studies, a single-segment cohort (S) and a double-segment cohort (D), 6 studies were included in the final meta-analysis. The flow chart used for the new systematic review according to PRISMA 2020 is shown in Figure 1.
Figure 1

PRISMA flowchart.

PRISMA flowchart.

Study Characteristics and Risk of Bias

A total of 491 patients and 633 vertebrae were involved in the 6 studies. The RA group included 232 patients and 311 vertebrae, and the FA group included 259 patients and 322 vertebrae. The characteristics of the included studies are presented in Table 1. All 6 cohort studies were evaluated by the Newcastle–Ottawa scale (NOS). The evaluation results are shown in Table 2.
Table 1

Demographics and characteristics of included studies.

AuthorYearCountryStudy DesignRA/FA
Patients SizeVertebrae sizeAge (mean, year)DiagnosisRobot typesMean Follow-Up (mos)
Alsalmi2019Francecohort studies30/3035/3249.4/40.6TVCFROSA/
Jin2021Chinacohort studies81/13181/13175.44/72.65OVCFTiRobot6.87/7.04
Lin2020Chinacohort studies33/3086/7568.8/67.9OVCFTiRobot11/13
Wang2021Chinacohort studies30/3030/3066/76OVCFTiRobot/
Yuan (d)2020Chinacohort studies37/2237/2271.5/70.3OVCFTiRobot6
Yuan (s)2020Chinacohort studies21/1642/3269.9/73.4OVCFTiRobot6

TVCF: traumatic vertebral compression fracture; OVCF: osteoporotic vetebral compression fracture.

Table 2

Newcastle-Ottawa scale for observational studies.

AuthorYearSelectionComparabilityOutcomesQuality judgment
Alsalmi20194239
Jin20214127
Lin20204228
Wang20214127
Yuan (d)20204228
Yuan (s)20204228

Selection: (1) representativeness of the exposed cohort, (2) selection of the nonexposed cohort, (3) ascer tainment of exposure and (4) demonstration that outcome of interest was not present at the start of stud.

Comparability: comparability of cohorts on the basis of the design or analysis.

Outcomes: (1) assessment outcome, (2) was follow-up long enough for outcomes to occur, (3) adequacy of follow-up of cohorts (≥1 years).

NOS scores ≥ 7 indicate a high-quality study.

Demographics and characteristics of included studies. TVCF: traumatic vertebral compression fracture; OVCF: osteoporotic vetebral compression fracture. Newcastle-Ottawa scale for observational studies. Selection: (1) representativeness of the exposed cohort, (2) selection of the nonexposed cohort, (3) ascer tainment of exposure and (4) demonstration that outcome of interest was not present at the start of stud. Comparability: comparability of cohorts on the basis of the design or analysis. Outcomes: (1) assessment outcome, (2) was follow-up long enough for outcomes to occur, (3) adequacy of follow-up of cohorts (≥1 years). NOS scores ≥ 7 indicate a high-quality study.

Meta-Analysis Results

The summary of the results of RA-kyphoplasty versus FA-kyphoplasty are shown in Table 3.
Table 3

Summarized results of robotic-assisted kyphoplasty versus fluoroscopy-assisted kyphoplasty.

VariablesNo. of studiesHeterogeneity test
Effect size
ModelConclusion
I2 (%)p valueOR/WMD95%CIp value
VH
 Postoperative VH300.372.891.72/4.06p < 0.001FixedSignifcant
 Final follow-up VH300.992.941.93/3.94p < 0.001FixedSignifcant
VKA
 Postoperative VKA6650.01−1.99−2.93/−1.05p < 0.001RandomSignifcant
 Final follow-up VKA4540.09−2.19−3.27/−1.10p < 0.001RandomSignifcant
VAS score for back pain
 Postoperative VAS600.66−0.23−0.41/−0.060.01FixedSignifcant
 Final follow-up VAS400.95−0.14−0.28/−0.010.03FixedSignifcant
cement leakage600.800.290.17/0.49p < 0.001FixedSignifcant

VH, vetebral height; VKA, vetebral kyphosis angle; VAS, visual analogue scale.

Summarized results of robotic-assisted kyphoplasty versus fluoroscopy-assisted kyphoplasty. VH, vetebral height; VKA, vetebral kyphosis angle; VAS, visual analogue scale.

Vertebral Height

A total of 3 studies (15, 18) reported the preoperative, postoperative, and final follow-up vertebral height in 345 vertebrae (160 vertebrae in the RA group and 185 vertebrae in the FA group). No significant statistical heterogeneity was detected(I2 = 0% in each subgroup). The outcomes indicated that although the degree of preoperative vertebral body compression in the RA group was slightly lower than that in the FA group, the restored height of the vertebrae tended to be significantly greater in the RA group than that in the FA group following the operation. Slightly statistically difference in the preoperative vertebral height (WMD = 0.93, 95% CI:(0.007,1.79), p = 0.03), significant statistically differences in vertebral height were observed at postoperation (WMD = 2.89, 95% CI:(1.72,4.06), p < 0.001) and final follow-up (WMD = 2.94, 95% CI:(1.93, 3.94), p < 0.001). (Figure 2).
Figure 2

Forest plot depicting WMDs of the vertebral height.

Forest plot depicting WMDs of the vertebral height.

Vertebral Kyphosis Angle

A total of 6 studies (14–18) reported preoperative, postoperative, and final follow-up kyphosis angles in 633 vertebrae (311 vertebrae in the RA group and 322 vertebrae in the FA group). Because minor statistical heterogeneity was detected (I2 = 25%, 65%, 54%, respectively), the random-effect model was used to analyze the merged variables. The outcomes indicated that the preoperative vertebral kyphosis angle was not significantly different between the groups (WMD = 0.02, 95% CI: (−0.88, 0.92), p = 0.97), while the kyphosis angles were significantly different between the groups postoperatively (WMD = −1.99, 95% CI: (−2.93, −1.05), p < 0.001) and at the final follow-up (WMD = −2.19, 95% CI: (−3.27, −1.10), p < 0.001) (Figure 3). According to the findings, robot-assisted kyphoplasty is more effective for correcting kyphotic deformities caused by vertebral compression.
Figure 3

Forest plot depicting WMDs of the vertebral kyphosis angle.

Forest plot depicting WMDs of the vertebral kyphosis angle.

VAS Score for Back Pain

Six studies (14–18) compared the preoperative, postoperative, and final follow-up VAS scores of the RA and FA groups (232 patients in the RA group and 259 patients in the FA group). No significant statistical heterogeneity was found (I2 = 0% in each subgroup). There was no statistically detectable difference between the RA group and the FA group in preoperative VAS score (WMD = −0.01, 95% CI: (−0.28, 0.26), p = 0.94). However, there was a statistically significant difference between patients undergoing RA-kyphoplasty versus those undergoing FA-kyphoplasty regarding postoperative back pain VAS score (WMD = −0.23, 95% CI:(−0.41, 0.06), p = 0.01) and final follow-up back pain VAS score (WMD = −0.14, 95% CI:(−0.28, 0.01), p = 0.03) (Figure 4).
Figure 4

Forest plot depicting WMDs of the VAS scores for back pain.

Forest plot depicting WMDs of the VAS scores for back pain.

Cement Leakage Rate

Six studies (14–18) compared the cement leakage rate between the RA group and the FA group (311 vertebrae in the RA group and 322 vertebrae in the FA group). The meta-analysis was conducted using a fixed-effect model with I2 = 0%. The outcomes indicated that cement leakage rate was lower in the RA group than in the FA group (OR  = 0.29, 95% CI: (0.17, 0.49), p < 0.001). (Figure 5).
Figure 5

Forest plot depicting the OR of the cement leakage rates.

Forest plot depicting the OR of the cement leakage rates.

Sensitivity Analyses and Publication Bias

Sensitivity analyses did not provide different results in terms of vertebral height, vertebral kyphosis angle, VAS score for back pain and cement leakage rate, by reanalyzing the data after sequential single elimination of each studies. Publication bias was not evident based on funnel plots as shown in Figures 6–9.
Figure 6

Funnel plot of vertebral height.

Figure 9

Funnel plot of cement leakage rates.

Funnel plot of vertebral height. Funnel plot of the vertebral kyphosis angle. Funnel plot of VAS scores for back pain. Funnel plot of cement leakage rates.

Discussion

This meta-analysis investigated the effects of robot use on postoperative clinical and radiological outcomes for patients undergoing kyphoplasty surgery. The results showed that RA-kyphoplasty produced better results than FA-kyphoplasty with regard to vertebral height, vertebral kyphosis angle, VAS score for back pain, and cement leakage rates postoperatively and also at the final follow-up. Correction of vertebral height and kyphosis angle appears to be important factors in a patient's overall improvement. It is necessary to reestablish the sagittal balance of the spine after vertebral compression fractures, which may be particularly problematic in younger patients (19, 20). However, the correction of the sagittal balance of the spine is often inadequate, as the range of motion of a fluoroscopy-guided needle is often limited, especially when accompanied by scoliosis or slipped deformity (21), because fluoroscopy-assisted pedicle puncture relies on anatomical landmarks for positioning. In addition, for the upper thoracic vertebrae (T1–T4), the pedicles are small and obstructed by the humeral head and scapula, making it difficult to identify clearly by intraoperative fluoroscopy. Therefore, one of the limitations of fluoroscopic pedicle puncture is that the balloon or other implant cannot be placed in the most severely collapsed vertebral body. Robot-assisted technology can theoretically solve the above problems and is valuable for the optimal positioning of the implants. The entry point, orientation, and final position of the implant can be planned preoperatively. The position of the implants in the vertebral body can be continuously optimized through 3D visualization. This function allows the implants to be placed precisely according to the surgeon’s plan. For example, the implant can be placed at the point of the lowest collapse in the vertebral body, which not only allows for better restoration of vertebral height but also reduces damage to the wall of the vertebral body and pedicle during the implantation process. In addition, the robot can eliminate the errors caused by surgeon's fatigue or tremors during manual operation, which also helps obtain the optimal position of the implants. Several previous studies (22–24) have shown that the distribution of bone cement is related to residual pain after kyphoplasty. With RA-kyphoplasty, the implants can be accurately positioned near the midline or fracture line, allowing the cement to be diffusely distributed along the midline of the vertebral body or fractured area, which can provide better pain relief. In addition, traditional fluoroscopy-assisted pedicle puncture often requires repeated adjustment of the puncture angle to ensure that the puncture needle does not violate the wall of the pedicle. This will inevitably aggravate the damage to muscles, fascia, and other soft tissues, resulting in inadequate postoperative pain relief. In contrast, RA-kyphoplasty is free of these problems. Our meta-analysis showed that the RA group experienced more adequate pain relief than the FA group, and this advantage persisted at the final follow-up, which may be related to the more adequate correction of vertebral kyphosis in the robot group (25, 26). Cement leakage after kyphoplasty is a problem to be solved, and specific morbidity has been reported in the literature (27). Our meta-analysis showed a marked difference in cement leakage rate between the RA group and the FA group (10.3% vs. 19.9%, p < 0.001). Undoubtedly, the precision of the robot-assisted puncture can prevent damages to the wall of the pedicle and vertebral body, thereby reducing the risk of cement leakage. However, cement leakage can still be caused by a variety of factors, such as the amount of cement injected, fracture severity, and intravertebral fissures (28, 29). Additional reasons for the reduction of cement leakage with RA-kyphoplasty need to be further explored in randomized controlled trials with larger sample sizes. Frequency and doses of radiation exposure and operative time are important parameters for evaluating the merits of robot-assisted surgery. Unfortunately, those data could not be pooled for analysis because of the large heterogeneity among the included studies. The differences in frequency and doses of radiation exposure were due to differences in the registration design of different robots. The “Mazor” (“SpineAssist”, “Renaissance”) robotic system plans the puncture path through three-dimensional images from computed tomography (CT) before surgery and performs the registration procedure only through the anterior-posterior and lateral position images from the C-arm during surgery. However, the “Rosa” and “TiRobot” robotic systems require automatic registration through intraoperative three-dimensional C-arm scanning. Although intraoperative three-dimensional C-arm scanning significantly increases the patient’s radiation exposure doses during surgery, it can reduce the total radiation exposure doses during hospitalization because three-dimensional C-arm scanning at the end of surgery can replace routine postoperative CT scanning (14). We favor this approach because the radiation doses from CT scanning are much greater than those from intraoperative three-dimensional C-arm scanning. The operation time varies depending on the type of robot, proficiency level of the operator, and location and number of fractured segments. Critics believe that RA-kyphoplasty is complex and time-consuming; for example, Yuan (18) used the “TiRobot” robot to perform single-segment kyphoplasty, which required 45.4 ± 6.1 min, and this was higher than that of the FA-kyphoplasty (36.1 ± 5.7 min). He believed that the main reason for the longer operation duration was the additional preparation time required by the robot. Jin (15) also used the “TiRobot” robot to perform single-segment kyphoplasty, and the procedure time was 37.33 ± 4.81 min, which was shorter than that of the FA-kyphoplasty (47.21 ± 6.10 min). We believe that the pre-surgical preparation of the robot could be carried out by a skilled radiographer, and surgeons work methodically with other operating room staff so that the preparation of the robot does not become a waste of time. Most clinical studies focus on the accuracy of robotic-assisted pedicle screw fixation in spine surgery (30, 31). However, the potential value of robot-assisted kyphoplasty in improving the reliability and quality of vertebral height restoration has not been evaluated. The results of this meta-analysis may play a role in the exploration of spinal robotics from assisting pedicle screw placement to assisting different surgical approaches for various types of spinal disorders, such as robot-assisted kyphoplasty.

Limitations

First, there were no randomized controlled trials in any of the included studies. However, funnel plots indicated minimal to no bias for observational studies, as shown in Figures. 6–9. Second, although all samples were patients with vertebral compression fractures, different causes of fractures may potentially affect outcomes. Third, radiation exposure frequency and doses and operation time could not be pooled for analysis due to the substantial heterogeneity between the included studies. Fourth, randomized controlled trials or observational studies with longer follow-ups are needed to supplement the existing conclusions.

Conclusions

This meta-analysis demonstrated that RA-kyphoplasty outperformed FA-kyphoplasty concerning vertebral height restoration, kyphosis angle correction, VAS score reduction for back pain, and reduction of cement leakage in the treatment of vertebral compression fractures.
  31 in total

1.  Radiation exposure and the orthopedic surgeon's hand: Measurement of the equivalent dose over 13 months.

Authors:  F Loisel; G Menu; E Boyer; I Pluvy; L Obert
Journal:  Hand Surg Rehabil       Date:  2017-02-13       Impact factor: 0.969

2.  Minimum cement volume required in vertebral body augmentation--A biomechanical study comparing the permanent SpineJack device and balloon kyphoplasty in traumatic fracture.

Authors:  Robert Rotter; Lena Schmitt; Philip Gierer; Klaus-Peter Schmitz; David Noriega; Thomas Mittlmeier; Peter-J Meeder; Heiner Martin
Journal:  Clin Biomech (Bristol, Avon)       Date:  2015-05-05       Impact factor: 2.063

3.  Balloon kyphoplasty for vertebral compression fracture using a unilateral balloon tamp via a uni-pedicular approach: technical note.

Authors:  Brian L Hoh; James D Rabinov; Johnny C Pryor; Joshua A Hirsch
Journal:  Pain Physician       Date:  2004-01       Impact factor: 4.965

4.  Kyphoplasty as an alternative treatment of traumatic thoracolumbar burst fractures Magerl type A3.

Authors:  Frank Hartmann; Erol Gercek; Lisa Leiner; Pol Maria Rommens
Journal:  Injury       Date:  2010-04-24       Impact factor: 2.586

5.  A prospective, randomized, controlled trial of robot-assisted vs freehand pedicle screw fixation in spine surgery.

Authors:  Ho-Joong Kim; Whan-Ik Jung; Bong-Soon Chang; Choon-Ki Lee; Kyoung-Tak Kang; Jin S Yeom
Journal:  Int J Med Robot       Date:  2016-09-27       Impact factor: 2.547

6.  Functional outcomes after surgery for spinal fractures: return to work and activity.

Authors:  Robert F McLain
Journal:  Spine (Phila Pa 1976)       Date:  2004-02-15       Impact factor: 3.468

7.  Global sagittal alignment of the spine, pelvis, lower limb after vertebral compression fracture and its effect on quality of life.

Authors:  Leo Tsz Ching Chau; Zongshan Hu; Koko Shaau Yiu Ko; Gene Chi Wai Man; Kwong Hang Yeung; Ying Yeung Law; Lawrence Chun Man Lau; Ronald Man Yeung Wong; Winnie Chiu Wing Chu; Jack Chun Yiu Cheng; Sheung Wai Law
Journal:  BMC Musculoskelet Disord       Date:  2021-05-24       Impact factor: 2.362

8.  Robot-Assisted Versus Fluoroscopy-Assisted Kyphoplasty in the Treatment of Osteoporotic Vertebral Compression Fracture: A Retrospective Study.

Authors:  Wei Yuan; Xiaotong Meng; Wenhai Cao; Yue Zhu
Journal:  Global Spine J       Date:  2020-12-30

9.  A mysterious risk factor for bone cement leakage into the spinal canal through the Batson vein during percutaneous kyphoplasty: a case control study.

Authors:  Shuai Zhang; Gao Ju Wang; Qing Wang; Jin Yang; Shuang Xu; Chao Hua Yang
Journal:  BMC Musculoskelet Disord       Date:  2019-09-12       Impact factor: 2.362

10.  Effectiveness of Tirobot-assisted vertebroplasty in treating thoracolumbar osteoporotic compression fracture.

Authors:  Boyao Wang; Jiang Cao; Jie Chang; Guoyong Yin; Weihua Cai; Qingqing Li; Zhenfei Huang; Lipeng Yu; Xiaojian Cao
Journal:  J Orthop Surg Res       Date:  2021-01-19       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.