Literature DB >> 28325434

Radiation exposure and the orthopedic surgeon's hand: Measurement of the equivalent dose over 13 months.

F Loisel1, G Menu2, E Boyer2, I Pluvy2, L Obert2.   

Abstract

Exposure to ionizing radiation in the operating room is governed by practical prevention and protection measures on the international, national and local levels. We evaluated the equivalent dose to the hand of an orthopedic surgeon over 13 months. An orthopedic surgeon wore a ring dosimeter on the ring finger of his right hand for all surgical procedures requiring intraoperative fluoroscopy between March 2014 and April 2015. Monthly doses were evaluated by the IRSN over the study period. The number and type of procedures were compiled as well as the type of fluoroscopy unit used. Four hundred procedures were performed during this period, including 182 with fluoroscopy. The equivalent cumulative dose at the hand was 4,75 mSv. No correlation was found with the type of procedure or type of fluoroscopy unit (conventional or mini C-arm). Equivalent doses were below the annual regulatory limit in France of 500 mSv. These results are consistent with those reported in the literature. However, recent studies have noted that both younger surgeons in training and more experienced surgeons must remember to use radiation protection measures.
Copyright © 2017 SFCM. Published by Elsevier Masson SAS. All rights reserved.

Keywords:  Chirurgie orthopédique; Dosimètre bague; Exposition radiologique; Orthopedic surgery; Radiation exposure; Radioprotection; Ring dosimeter; Traumatologie; Traumatology

Mesh:

Year:  2017        PMID: 28325434     DOI: 10.1016/j.hansur.2016.11.006

Source DB:  PubMed          Journal:  Hand Surg Rehabil        ISSN: 2468-1210            Impact factor:   0.969


  5 in total

1.  Atlas-based automatic planning and 3D-2D fluoroscopic guidance in pelvic trauma surgery.

Authors:  R Han; A Uneri; T De Silva; M Ketcha; J Goerres; S Vogt; G Kleinszig; G Osgood; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2019-05-02       Impact factor: 4.174

2.  Effectiveness of Tirobot-assisted vertebroplasty in treating thoracolumbar osteoporotic compression fracture.

Authors:  Boyao Wang; Jiang Cao; Jie Chang; Guoyong Yin; Weihua Cai; Qingqing Li; Zhenfei Huang; Lipeng Yu; Xiaojian Cao
Journal:  J Orthop Surg Res       Date:  2021-01-19       Impact factor: 2.359

Review 3.  Robot-Assisted Kyphoplasty Improves Clinical and Radiological Features Better Than Fluoroscopy-Assisted Kyphoplasty in the Treatment of Vertebral Compression Fractures: A Meta-Analysis.

Authors:  Hongwei Yu; Gan Luo; Bin Yu; Tianwei Sun; Qiong Tang; Yutao Jia
Journal:  Front Surg       Date:  2022-07-05

4.  A Case of Central Posterior Epidural Cyst Associated with Baastrup's Disease Punctured Percutaneously Using Fluoroscopy with a Good Outcome.

Authors:  Satoshi Baba; Mitsumasa Hayashida; Kazuki Kitade; Eiji Kinoshita; Kenji Urata; Yu Matsushita; Waichirou Oka; Norihiro Komiya; Nobuaki Tsukamoto; Takao Mae; Yasuharu Nakashima
Journal:  Spine Surg Relat Res       Date:  2020-04-20

5.  Comparison of the modified Wiltse's approach with spinal minimally invasive system and traditional approach for the therapy of thoracolumbar fracture.

Authors:  Jie Chang; Jiang Cao; Ziyan Huang; Boyao Wang; Tao Sui; Xiaojian Cao
Journal:  J Biomed Res       Date:  2020-07-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.