Literature DB >> 33468187

Effectiveness of Tirobot-assisted vertebroplasty in treating thoracolumbar osteoporotic compression fracture.

Boyao Wang1, Jiang Cao1, Jie Chang1, Guoyong Yin1, Weihua Cai1, Qingqing Li1, Zhenfei Huang1, Lipeng Yu2, Xiaojian Cao3.   

Abstract

BACKGROUND: Percutaneous kyphoplasty is the main method in the treatment of thoracolumbar osteoporotic compression fractures. However, much radiation exposure during the operation harms the health of surgeons and patients. In addition, the accuracy of this surgery still needs to be improved. This study aimed to assess the radiation exposure and clinical efficacy of Tirobot-assisted vertebroplasty in treating thoracolumbar osteoporotic compression fracture.
METHODS: Included in this retrospective cohort study were 60 patients (60-90 years) who had undergone unilateral vertebroplasty for thoracolumbar osteoporotic compression fracture at our hospital between June 2019 and June 2020. All showed no systemic diseases and were assigned to Tirobot group (treated with Tirobot-assisted approach) and control group (treated with traditional approach). Fluoroscopic frequency, operative duration, length of stay (LOS), post-operative complications (cement leakage, infection, and thrombosis), and pre-operative and pre-discharge indexes (VAS score, JOA score, and Cobb's angle) were compared.
RESULTS: The fluoroscopic frequency (P < 0.001) and post-operative complications (P = 0.035) in Tirobot group were significantly lower than those in control group. The operative duration and LOS in the Tirobot group were shorter than those in the control group, but the differences were not statistically significant (P = 0.183). Pre-discharge VAS score and Cobb's angle decreased, and JOA increased after surgeries in both groups. These three indexes showed a significant difference after surgery in each group (P < 0.001), but not between groups (PVAS = 0.175, PCobb's = 0.585, PJOA = 0.448).
CONCLUSION: The Tirobot-assisted vertebroplasty can reduce surgery-related trauma, post-operative complications, and patients' and operators' exposure to radiation. As a safe and effective strategy, this surgery can realize the quick recovery from thoracolumbar osteoporotic compression fracture.

Entities:  

Keywords:  Compression fracture; Robot; Vertebroplasty

Mesh:

Year:  2021        PMID: 33468187      PMCID: PMC7816462          DOI: 10.1186/s13018-021-02211-0

Source DB:  PubMed          Journal:  J Orthop Surg Res        ISSN: 1749-799X            Impact factor:   2.359


  30 in total

Review 1.  Thoracic and lumbar spine trauma.

Authors:  J J Kaye; E P Nance
Journal:  Radiol Clin North Am       Date:  1990-03       Impact factor: 2.303

Review 2.  Risk Factors for Cement Leakage After Vertebroplasty or Kyphoplasty: A Meta-Analysis of Published Evidence.

Authors:  Yi Zhan; Jianzhong Jiang; Haifen Liao; Haitao Tan; Keqin Yang
Journal:  World Neurosurg       Date:  2017-02-10       Impact factor: 2.104

3.  Computer-assisted spine surgery: a technique for accurate transpedicular screw fixation using CT data and a 3-D optical localizer.

Authors:  S Lavallée; P Sautot; J Troccaz; P Cinquin; P Merloz
Journal:  J Image Guid Surg       Date:  1995

Review 4.  Management of thoracolumbar spine fractures.

Authors:  Kirkham B Wood; Weishi Li; Darren R Lebl; Darren S Lebl; Avraam Ploumis
Journal:  Spine J       Date:  2014-01       Impact factor: 4.166

Review 5.  Robotic navigation during spine surgery.

Authors:  Qi Zhang; Xiao-Guang Han; Yun-Feng Xu; Ming-Xing Fan; Jing-Wei Zhao; Ya-Jun Liu; Da He; Wei Tian
Journal:  Expert Rev Med Devices       Date:  2019-12-04       Impact factor: 3.166

6.  Comparison of percutaneous balloon dilation kyphoplasty and percutaneous vertebroplasty in treatment for thoracolumbar vertebral compression fractures.

Authors:  K-Z Hu; S-C Chen; L Xu
Journal:  Eur Rev Med Pharmacol Sci       Date:  2018-07       Impact factor: 3.507

Review 7.  Unilateral versus bilateral percutaneous kyphoplasty for osteoporotic vertebral compression fractures: A meta-analysis.

Authors:  Wenli Chang; Xinyan Zhang; Ning Jiao; Peizhi Yuwen; Yanbin Zhu; Fei Zhang; Wei Chen
Journal:  Medicine (Baltimore)       Date:  2017-04       Impact factor: 1.889

Review 8.  Network meta-analysis of percutaneous vertebroplasty, percutaneous kyphoplasty, nerve block, and conservative treatment for nonsurgery options of acute/subacute and chronic osteoporotic vertebral compression fractures (OVCFs) in short-term and long-term effects.

Authors:  Xiao-Hua Zuo; Xue-Piao Zhu; Hong-Guang Bao; Chen-Jie Xu; Hao Chen; Xian-Zhong Gao; Qian-Xi Zhang
Journal:  Medicine (Baltimore)       Date:  2018-07       Impact factor: 1.889

9.  Comparative Study of Percutaneous Sacroiliac Screw with or without TiRobot Assistance for Treating Pelvic Posterior Ring Fractures.

Authors:  Tao Long; Kai-Nan Li; Jin-Hua Gao; Tian-Hu Liu; Jian-Song Mu; Xue-Jun Wang; Chao Peng; Zhi-Yong He
Journal:  Orthop Surg       Date:  2019-05-11       Impact factor: 2.071

Review 10.  Percutaneous vertebroplasty for osteoporotic vertebral compression fracture.

Authors:  Rachelle Buchbinder; Renea V Johnston; Kobi J Rischin; Joanne Homik; C Allyson Jones; Kamran Golmohammadi; David F Kallmes
Journal:  Cochrane Database Syst Rev       Date:  2018-04-04
View more
  5 in total

Review 1.  Current status and challenges of percutaneous vertebroplasty (PVP).

Authors:  Tomoyuki Noguchi; Koji Yamashita; Ryotaro Kamei; Junki Maehara
Journal:  Jpn J Radiol       Date:  2022-08-09       Impact factor: 2.701

2.  TiRobot-assisted percutaneous kyphoplasty in the management of multilevel (more than three levels) osteoporotic vertebral compression fracture.

Authors:  Shu Lin; Liu-Yi Tang; Fei Wang; Xin-Wei Yuan; Jiang Hu; Wei-Min Liang
Journal:  Int Orthop       Date:  2022-09-14       Impact factor: 3.479

3.  Design and evaluation of an intelligent reduction robot system for the minimally invasive reduction in pelvic fractures.

Authors:  Chunpeng Zhao; Yu Wang; Xinbao Wu; Gang Zhu; Shuchang Shi
Journal:  J Orthop Surg Res       Date:  2022-04-04       Impact factor: 2.359

4.  Accuracy of vertebral puncture in percutaneous vertebroplasty.

Authors:  Tomoyuki Noguchi; Koji Yamashita; Yoshitaka Shida; Takashi Okafuji; Ryotaro Kamei; Junki Maehara; Tsuyoshi Tajima
Journal:  Jpn J Radiol       Date:  2021-11-05       Impact factor: 2.374

Review 5.  Robot-Assisted Kyphoplasty Improves Clinical and Radiological Features Better Than Fluoroscopy-Assisted Kyphoplasty in the Treatment of Vertebral Compression Fractures: A Meta-Analysis.

Authors:  Hongwei Yu; Gan Luo; Bin Yu; Tianwei Sun; Qiong Tang; Yutao Jia
Journal:  Front Surg       Date:  2022-07-05
  5 in total