Literature DB >> 35862434

Structure Detection in Three-Dimensional Cellular Cryoelectron Tomograms by Reconstructing Two-Dimensional Annotated Tilt Series.

Xiangrui Zeng1, Ziqian Lin2, Mostofa Rafid Uddin1, Bo Zhou3, Chao Cheng4, Jing Zhang5, Zachary Freyberg6, Min Xu1.   

Abstract

The revolutionary technique cryoelectron tomography (cryo-ET) enables imaging of cellular structure and organization in a near-native environment at submolecular resolution, which is vital to subsequent data analysis and modeling. The conventional structure detection process first reconstructs the three-dimensional (3D) tomogram from a series of two-dimensional (2D) projections and then directly detects subcellular components found within the tomogram. However, this process is challenging due to potential structural information loss during the tomographic reconstruction and the limited scope of existing methods since most major state-of-the-art object detection methods are designed for 2D rather than 3D images. Therefore, in this article, as an alternative approach to complement the conventional process, we propose a novel 2D-to-3D framework that detects structures within 2D projection images before reconstructing the results back to 3D. We implemented the proposed framework as three specific algorithms for three individual tasks: semantic segmentation, edge detection, and object localization. As experimental validation of the 2D-to-3D framework for cryo-ET data, we applied the algorithms to the segmentation of mitochondrial calcium phosphate granules, detection of spherical edges, and localization of mitochondria. Quantitative and qualitative results show better performance for prediction tasks of segmentation on the 2D projections and promising performance on object localization and edge detection, paving the way for future studies in the exploration of cryo-ET for in situ structural biology.

Entities:  

Keywords:  backward projection; cryoelectron tomography; edge detection; object localization; semantic segmentation

Mesh:

Year:  2022        PMID: 35862434      PMCID: PMC9419945          DOI: 10.1089/cmb.2021.0606

Source DB:  PubMed          Journal:  J Comput Biol        ISSN: 1066-5277            Impact factor:   1.549


  23 in total

1.  Missing wedge computed tomography by iterative algorithm DIRECTT.

Authors:  Andreas Kupsch; Axel Lange; Manfred P Hentschel; Sebastian Lück; Volker Schmidt; Roman Grothausmann; André Hilger; Ingo Manke
Journal:  J Microsc       Date:  2015-09-14       Impact factor: 1.758

Review 2.  Cellular structural biology as revealed by cryo-electron tomography.

Authors:  Rossitza N Irobalieva; Bruno Martins; Ohad Medalia
Journal:  J Cell Sci       Date:  2016-01-19       Impact factor: 5.285

Review 3.  New views of cells in 3D: an introduction to electron tomography.

Authors:  Richard McIntosh; Daniela Nicastro; David Mastronarde
Journal:  Trends Cell Biol       Date:  2005-01       Impact factor: 20.808

4.  Image fusion in dual energy computed tomography: effect on contrast enhancement, signal-to-noise ratio and image quality in computed tomography angiography.

Authors:  Florian F Behrendt; Bernhard Schmidt; Cédric Plumhans; Sebastian Keil; Seth G Woodruff; Diana Ackermann; Georg Mühlenbruch; Thomas Flohr; Rolf W Günther; Andreas H Mahnken
Journal:  Invest Radiol       Date:  2009-01       Impact factor: 6.016

5.  Feature Decomposition Based Saliency Detection in Electron Cryo-Tomograms.

Authors:  Bo Zhou; Qiang Guo; Xiangrui Zeng; Min Xu
Journal:  Proceedings (IEEE Int Conf Bioinformatics Biomed)       Date:  2019-01-24

6.  Compensation of missing wedge effects with sequential statistical reconstruction in electron tomography.

Authors:  Lassi Paavolainen; Erman Acar; Uygar Tuna; Sari Peltonen; Toshio Moriya; Pan Soonsawad; Varpu Marjomäki; R Holland Cheng; Ulla Ruotsalainen
Journal:  PLoS One       Date:  2014-10-03       Impact factor: 3.240

7.  Structural Basis of Vesicle Formation at the Inner Nuclear Membrane.

Authors:  Christoph Hagen; Kyle C Dent; Tzviya Zeev-Ben-Mordehai; Michael Grange; Jens B Bosse; Cathy Whittle; Barbara G Klupp; C Alistair Siebert; Daven Vasishtan; Felix J B Bäuerlein; Juliana Cheleski; Stephan Werner; Peter Guttmann; Stefan Rehbein; Katja Henzler; Justin Demmerle; Barbara Adler; Ulrich Koszinowski; Lothar Schermelleh; Gerd Schneider; Lynn W Enquist; Jürgen M Plitzko; Thomas C Mettenleiter; Kay Grünewald
Journal:  Cell       Date:  2015-12-17       Impact factor: 41.582

8.  A Monte Carlo framework for missing wedge restoration and noise removal in cryo-electron tomography.

Authors:  Emmanuel Moebel; Charles Kervrann
Journal:  J Struct Biol X       Date:  2019-10-25

9.  LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure.

Authors:  Xiaobo Zhai; Dongsheng Lei; Meng Zhang; Jianfang Liu; Hao Wu; Yadong Yu; Lei Zhang; Gang Ren
Journal:  Sci Rep       Date:  2020-06-26       Impact factor: 4.996

10.  In-cell architecture of an actively transcribing-translating expressome.

Authors:  Francis J O'Reilly; Liang Xue; Andrea Graziadei; Ludwig Sinn; Swantje Lenz; Dimitry Tegunov; Cedric Blötz; Neil Singh; Wim J H Hagen; Patrick Cramer; Jörg Stülke; Julia Mahamid; Juri Rappsilber
Journal:  Science       Date:  2020-07-31       Impact factor: 47.728

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.