Literature DB >> 31205800

Feature Decomposition Based Saliency Detection in Electron Cryo-Tomograms.

Bo Zhou1, Qiang Guo2, Xiangrui Zeng3, Min Xu3.   

Abstract

Electron Cryo-Tomography (ECT) allows 3D visualization of subcellular structures at the submolecular resolution in close to the native state. However, due to the high degree of structural complexity and imaging limits, the automatic segmentation of cellular components from ECT images is very difficult. To complement and speed up existing segmentation methods, it is desirable to develop a generic cell component segmentation method that is 1) not specific to particular types of cellular components, 2) able to segment unknown cellular components, 3) fully unsupervised and does not rely on the availability of training data. As an important step towards this goal, in this paper, we propose a saliency detection method that computes the likelihood that a subregion in a tomogram stands out from the background. Our method consists of four steps: supervoxel over-segmentation, feature extraction, feature matrix decomposition, and computation of saliency. The method produces a distribution map that represents the regions' saliency in tomograms. Our experiments show that our method can successfully label most salient regions detected by a human observer, and able to filter out regions not containing cellular components. Therefore, our method can remove the majority of the background region, and significantly speed up the subsequent processing of segmentation and recognition of cellular components captured by ECT.

Entities:  

Keywords:  3D Gabor filter; Electron Cryo-Tomography; robust PCA; saliency detection; super-voxel segmentation

Year:  2019        PMID: 31205800      PMCID: PMC6571026          DOI: 10.1109/BIBM.2018.8621363

Source DB:  PubMed          Journal:  Proceedings (IEEE Int Conf Bioinformatics Biomed)        ISSN: 2156-1125


  3 in total

1.  Structure Detection in Three-Dimensional Cellular Cryoelectron Tomograms by Reconstructing Two-Dimensional Annotated Tilt Series.

Authors:  Xiangrui Zeng; Ziqian Lin; Mostofa Rafid Uddin; Bo Zhou; Chao Cheng; Jing Zhang; Zachary Freyberg; Min Xu
Journal:  J Comput Biol       Date:  2022-07-21       Impact factor: 1.549

2.  Fine-grained alignment of cryo-electron subtomograms based on MPI parallel optimization.

Authors:  Yongchun Lü; Xiangrui Zeng; Xiaofang Zhao; Shirui Li; Hua Li; Xin Gao; Min Xu
Journal:  BMC Bioinformatics       Date:  2019-08-28       Impact factor: 3.169

3.  One-Shot Learning With Attention-Guided Segmentation in Cryo-Electron Tomography.

Authors:  Bo Zhou; Haisu Yu; Xiangrui Zeng; Xiaoyan Yang; Jing Zhang; Min Xu
Journal:  Front Mol Biosci       Date:  2021-01-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.