Zilin Zhang1,2, Ekanem E Ekanem1,3, Mitsutoshi Nakajima4, Guido Bolognesi1, Goran T Vladisavljević1. 1. Department of Chemical Engineering, Loughborough University, Loughborough LE11 3TU, U.K. 2. Guangxi Key Laboratory of Green Chemical Materials and Safety Technology, Beibu Gulf University, Qinzhou 535011, China. 3. Department of Chemical Engineering, University of Bath, Bath BA2 7AY, U.K. 4. Faculty of Life and Environmental Sciences, University of Tsukuba, 1-1-1 Tennoudai, Tsukuba, Ibaraki 305-8572, Japan.
Abstract
Monodispersed sirolimus (SRL)-loaded poly(lactic-co-glycolic acid) microspheres with a diameter of 1.8, 3.8, and 8.5 μm were produced by high-throughput microfluidic step emulsification─solvent evaporation using single crystal silicon chips consisted of 540-1710 terraced microchannels with a depth of 2, 4, or 5 μm arranged in 10 parallel arrays. Uniform sized droplets were generated over 25 h across all channels. Nearly 15% of the total drug was released by the initial burst release during an accelerated drug release testing performed at 37 °C using a hydrotropic solution containing 5.8 M N,N-diethylnicotinamide. After 24 h, 71% of the drug was still entrapped in the particles. The internal morphology of microspheres was investigated by fluorescence microscopy using Nile red as a selective fluorescent stain with higher binding affinity toward SRL. By increasing the drug loading from 33 to 50 wt %, the particle morphology evolved from homogeneous microspheres, in which the drug and polymer were perfectly mixed, to patchy particles, with amorphous drug patches embedded within a polymer matrix to anisotropic patchy Janus particles. Janus particles with fully segregated drug and polymer regions were achieved by pre-saturating the aqueous phase with the organic solvent, which decreased the rate of solvent evaporation and allowed enough time for complete phase separation. This approach to manufacturing drug-loaded monodisperse microparticles can enable the development of more effective implantable drug-delivery devices and improved methods for subcutaneous drug administration, which can lead to better therapeutic treatments.
Monodispersed sirolimus (SRL)-loaded poly(lactic-co-glycolic acid) microspheres with a diameter of 1.8, 3.8, and 8.5 μm were produced by high-throughput microfluidic step emulsification─solvent evaporation using single crystal silicon chips consisted of 540-1710 terraced microchannels with a depth of 2, 4, or 5 μm arranged in 10 parallel arrays. Uniform sized droplets were generated over 25 h across all channels. Nearly 15% of the total drug was released by the initial burst release during an accelerated drug release testing performed at 37 °C using a hydrotropic solution containing 5.8 M N,N-diethylnicotinamide. After 24 h, 71% of the drug was still entrapped in the particles. The internal morphology of microspheres was investigated by fluorescence microscopy using Nile red as a selective fluorescent stain with higher binding affinity toward SRL. By increasing the drug loading from 33 to 50 wt %, the particle morphology evolved from homogeneous microspheres, in which the drug and polymer were perfectly mixed, to patchy particles, with amorphous drug patches embedded within a polymer matrix to anisotropic patchy Janus particles. Janus particles with fully segregated drug and polymer regions were achieved by pre-saturating the aqueous phase with the organic solvent, which decreased the rate of solvent evaporation and allowed enough time for complete phase separation. This approach to manufacturing drug-loaded monodisperse microparticles can enable the development of more effective implantable drug-delivery devices and improved methods for subcutaneous drug administration, which can lead to better therapeutic treatments.
Entities:
Keywords:
biodegradable polymer; controlled drug release; drug delivery; drug-eluting medical devices; poly(lactic-co-glycolic acid); step microfluidic emulsification
An implantable medical device is any instrument
used for diagnostic
and/or therapeutic purposes such as a stent or balloon, which is introduced
into the human body by clinical intervention and intended to remain
in place for an extended period.[1] Although
these devices are subject to rigorous health and safety requirements,
their intimate and prolonged contact with the human body increases
the risks of adverse events and reactions, such as formation of the
bacterial biofilm[2] and restenosis.[3] Restenosis is re-narrowing of the artery previously
treated for blockage and represents the greatest risk factor limiting
the success of percutaneous coronary interventions.[4]Coronary balloons and stents can be coated with an
anti-restenotic
drug which is slowly released at the contact area between the device
and the vessel wall to inhibit neointimal hyperplasia, the main cause
of restenosis.[5,6] Paclitaxel and sirolimus (SRL)
are the two major anti-restenotic drugs in drug-eluting medical devices.[7] Paclitaxel diffuses more readily through the
plaque and the vessel wall, but it is less effective in suppressing
restenosis and has a narrower therapeutic window compared to SRL.[8] As a result, a growing number of SRL-eluting
stents[9] and balloons[10] are receiving clinical approval.One of the most
important inventions in drug-eluting technology
is the adoption of a drug carrier (excipient) to facilitate drug transfer
to the vessel wall.[11] Without the excipient,
the drug forms crystalline lumps on the device surface, which inhibits
drug transfer, especially in drug-coated balloons due to short contact
time between the inflated balloon and the artery wall (30–120
s). Other benefits of encapsulating drugs include enhanced adhesion
of the drug to the device surface, increased stability of the coating
during handling, its improved adherence to the vessel wall, and extended
drug release to prolong therapeutic effects and minimize side effects.[11] Coating for drug-eluting medical devices often
consists of a homogeneous excipient layer saturated with a particular
drug. This approach provides high initial drug levels, but the drug
concentration rapidly decreases because the drug diffuses quickly
out of the surface region of the coating, and the coating soon becomes
depleted of the drug. One way of achieving a uniform drug release
over prolonged time is to prepare microspheres composed of a drug-excipient
mixture and then disperse these micro-reservoirs uniformly in a thin
layer of another hydrophobic material.[12] After implantation, drug molecules are slowly released from embedded
micro-reservoirs to the secondary hydrophobic matrix and then diffuse
through the matrix layer to the artery wall. The secondary matrix
should adhere well to the artery wall and should provide a good dispersion
of micro-reservoirs. The compounds that can be used to form a secondary
matrix are sterols, phospholipids, fats, and hydrophobic surfactants.[12]Poly(lactic-co-glycolic
acid) (PLGA) is the most
widely used biomaterial for drug encapsulation,[13] generally recognized as safe (GRAS) by FDA and the European
Medicines Agency (EMA).[14] Currently, there
are 19 FDA-approved PLGA-based drug products on the market, mainly
in the form of microspheres.[15] The particle
size is a key factor in their design, as it affects the drug encapsulation
efficiency, product injectability, distribution in the body, and drug
release rate.[14,16] Conventional methods of producing
PLGA microspheres, such as spray drying,[17] coacervation, high-speed mixing, or high-pressure homogenization
combined with solvent evaporation,[18] result
in wide particle size distributions with a coefficient of variation
(CV) of particle sizes of 30–50%. The particle size uniformity
can be improved through expensive classification processes, but they
are associated with high drug and polymer losses. Better control over
the particle size can be achieved using membrane emulsification, but
the CVs are still relatively high, between 7 and 20%.[19]Recent advances in microengineering and semiconductor
technologies
have enabled fabrication of microfluidic chips for generation of monodisperse
droplets with CVs less than 3%.[20] Droplet
microfluidics offers many advantages over conventional emulsification
methods including unprecedented control over the droplet size with
no polymer–drug losses, high drug encapsulation efficiency
because droplets are formed at negligible shear, and operation in
a closed environment enabling sterile manufacturing to meet the Current
Good Manufacturing Practice (CGMP) regulations.The main problem
of conventional microfluidic devices such as T-and
ψ-junctions[21,22] is a low droplet productivity
because droplets are produced one at a time, and the maximum throughput
is limited by dripping to jetting transition.[23] Scaling up T-junctions and flow focusing nozzles is challenging
because droplet formation in these geometries is controlled by the
shear rate at the interface between the dispersed phase and CP, which
is sensitive to fluid flow rates. As a result, small flow rate fluctuations
can result in large droplet size variations, making parallelization
of these devices difficult.[24] Step microfluidic
emulsification is an alternative approach of generating uniform droplets
in a low shear environment based on exploiting a sudden change in
the channel geometry from shallow channels to a deep and wide microwell.[25,26] Although the mechanism was discovered in the mid-1990s,[27] it was largely ignored until recent years.[28,29] The droplet size in step emulsification devices can be tuned solely
by the geometry of shallow channels. The effect of fluid flow rates
is negligible, which allows for easy multiplication of individual
channels.[30,31]Here, we report for the first time
the production of monodispersed
SRL-loaded PLGA microparticles by step microfluidic emulsification.
The microparticles are fabricated with the tunable size and internal
morphology using single-crystal silicon chips consisting of multiple
arrays of grooved MCs. The fabricated particles can be used for subcutaneous
SRL administration or as drug micro-reservoirs in SRL-coated balloons,
thereby offering new opportunities for the development of improved
restenosis treatments based on either subcutaneous drug injections
or implantable drug delivery systems.
Materials and Methods
Materials
SRL or rapamycin (SRL, purity > 99%) was
purchased from Chunghwa Chemical Synthesis & Biotech Co. Ltd (Taiwan).
PLGA (Mw = 10,000 g mol–1) containing 75% dl-lactic acid and 25% glycolic acid, purchased
from Wako Pure Chemical Industries (Osaka, Japan), was used as an
excipient. Poly(vinyl alcohol) (PVA, Mw = 13,000–23,000 g mol–1, 87–89%
hydrolyzed, Sigma-Aldrich, UK) dissolved in pure Milli-Q water or
dichloromethane (DCM)-saturated Milli-Q water served as a water-soluble
surfactant. DCM (HPLC grade, Fisher Scientific, UK) and isopropyl
acetate (IPAc, Sigma-Aldrich, UK) were used as solvents for PLGA and
SRL. Nile red (Sigma-Aldrich, UK) was added to the dispersed phase
as a fluorescent dye to investigate the internal morphology of the
particles.
MC Chips
Three cross-flow silicon microchips with terraced
MCs arranged in 10 parallel arrays were used for droplet generation
(Figure b). The MC
dimensions are shown in Table . The chips are designed in Nakajima Lab (NFRI, NARO, Tsukuba,
Japan) and EP Tech Co. Ltd., commercialized by EP Tech, Co., Ltd.,
and microfabricated by photolithography and deep reactive ion etching
by Hitachi Power Semiconductor Device, Ltd., Hitachi, Japan.
Figure 1
Schematics
of the microfluidics rig: (a) stainless steel module
with two syringe pumps, a collection syringe, and a reflected-light
microscope for observation of droplet generation; (b) silicon chip
with 5 cross-flow channels and 10 parallel rows of terraced microchannels
(MCs) (red labels are terrace numbers): A = inlet hole for the dispersed
phase, B = inlet holes for the continuous phase (CP), and C = outlet
hole for the emulsion. Red regions are dead-end channels for the dispersed
phase, and blue regions are cross-flow channels for the CP; (c) magnified
top view of a single dead-end channel in section D–D; (d) magnified
side view of the dead-end channel with two terrace walls; (e) terrace
wall with two MCs on the top and a deep well at each side.
Table 1
Geometry of the Chips Used in This
Study (See Also Figure e): DMC = MC Depth; WMC = MC Width; dh = Hydraulic
Diameter of a MC; LMC = MC Length; LT = Terrace Length; NMC = Total Number of MCs; nMC = Number
of MCs in a Single Row
CHIP
CMS6-1
CMS6-2
CMS6-3
DMC (μm)
5
4
2
WMC (μm)
18
8
12
dh (μm)
7.0
4.1
3.3
LMC (μm)
140
140
140
LT (μm)
60
30
30
NMC
540
1850
1710
nMC
54
185
171
Schematics
of the microfluidics rig: (a) stainless steel module
with two syringe pumps, a collection syringe, and a reflected-light
microscope for observation of droplet generation; (b) silicon chip
with 5 cross-flow channels and 10 parallel rows of terraced microchannels
(MCs) (red labels are terrace numbers): A = inlet hole for the dispersed
phase, B = inlet holes for the continuous phase (CP), and C = outlet
hole for the emulsion. Red regions are dead-end channels for the dispersed
phase, and blue regions are cross-flow channels for the CP; (c) magnified
top view of a single dead-end channel in section D–D; (d) magnified
side view of the dead-end channel with two terrace walls; (e) terrace
wall with two MCs on the top and a deep well at each side.
Chip Cleaning
The used chip was washed in a Fisherbrand
FB11003 ultrasound bath at 10% power using a mild detergent dissolved
in a mixture of water and ethanol. The chip was then rinsed with Milli-Q
water, oven-dried, and transferred to a plasma cleaner (Fischione
1020) to oxidize persistent organic contaminants that could not be
removed by the detergent. The plasma oxidation was performed at 0.01
Pa for 15 min (pure O2) or 20 min (25% O2 and
75% Ar). After cleaning, the chip was placed on a watch glass and
stored in the CP. To evaluate the cleaning process, the contact angle
between a water droplet and a dry chip surface was measured by using
the Krüss Model DSA 100 Advanced drop shape analyzer.
Drop Generation
A clean chip was placed in a module
(Figure a) filled
with the CP. The dispersed phase was then delivered to the module
via hole A (Figure a–d) and distributed across six dead-end channels until it
overflowed the upstream terraces. The flow rate was then adjusted
to 0.02–0.05 mL/h (Table ) to force the dispersed phase through MCs. The CP
was delivered through hole B (Figure b) and flowed through five cross-flow channels. When
disk-like dispersed phase jets on the downstream terraces reached
the terrace edge, they were pulled into the CP stream by the imbalance
in the capillary pressure along the interface, which caused the jet
to pinch-off and release drops. The emulsion was removed through hole
C. The bottom window was used for the observation of droplet generation
by using a reflected-light microscope (MS-511-M; Seiwa Optical Co.,
Ltd., Tokyo).
Table 2
Experimental Conditions, Emulsion
Formulations, and Droplet/Particle Sizes for Different Sample Runs
S1
S2
S3
S4
S5
S6
S7
S8
S9
nominal channel depth, DMC (μm)
5
4
2
4
4
4
4
4
4
dispersed phase composition (wt %)
SRL
1.32
1.32
1.32
1.32
1.64
1.76
1.80
1.84
2.25
PLGA
2.68
2.68
2.68
2.68
2.34
2.24
2.20
2.16
2.25
IPAc
72.00
72.00
72.00
72.00
72.00
72.00
72.00
72.00
71.63
DCM
24.00
24.00
24.00
24.00
24.00
24.00
24.00
24.00
23.88
CP composition (wt %)
PVA
1.50
1.50
1.50
1.50
1.50
1.00
1.00
1.00
1.00
Milli-Q water
98.50
98.50
98.50
98.50
98.50
99.00
99.00
99.00
99.00
drug loading (wt %)
33
33
33
33
42
44
45
46
50
total solids in the dispersed
phase (wt %)
4
4
4
4
4
4
4
4
5
droplet production time
48 h
24 h
24 h
24 h
48 h
24 h
24 h
24 h
24 h
flowrate (mL/h)
dispersed phase
0.15
0.03
0.01
0.03
0.05
0.02
0.05
0.02
CP
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
mean droplet size (μm)
23.5
13.8
5.2
13.8
13.8
13.8
13.6
13.8
13.5
CV of droplet sizes (%)
3.0
2.5
3.5
2.5
3.0
2.6
2.0
2.5
2.4
predicted particle size (μm)
7.0
4.1
1.5
4.1
4.2
4.2
4.3
4.3
4.5
mean
particle size (μm)
8.5
3.8
1.8
4.2
4.0
4.2
4.2
4.2
4.3
CV of particle sizes (%)
4.5
5.2
6.0
5.2
4.1
4.3
5.1
4.8
4.6
Droplet Size Analysis
Droplet generation was observed
using a color CCD camera (LCL-211H, Watec America Corp., USA), 30
frames per second, 720 × 480 resolution, and recorded with Ulead
Video Studio 11 SE DVD video editing software (InterVideo Digital
Technology Corp.). The CV was calculated aswhere σ is the standard deviation, and D̅d is the average droplet diameter based
on at least 30 droplets. The droplet diameters were measured using
ImageJ software. The particle diameter was predicted using the mass
balance of non-volatile solids in the dispersed phase by assuming
zero particle porositywhere Dp,p is
the predicted particle diameter, xs is
the mass fraction of non-volatile solids in the dispersed phase, and
ρp and ρd are the density of particles
and droplets, respectively.
Particle Preparation
The particles were formed upon
DCM evaporation from the droplets. The residual PVA was removed from
the suspension through multiple washing cycles. Each washing cycle
consisted of centrifuging the suspension at 3500 rpm for 10 min, removing
the supernatant with a Pasteur pipette, adding an equal volume of
0.05 wt % Tween 20 solution, and vortexing for 5–10 s. The
concentration of residual PVA in the supernatant was measured using
the PerkinElmer Lambda 35 UV–vis spectrometer. After final
wash, the level of the supernatant in the vial was reduced just above
the level of the sediment and the particles were dried using the AdVantage
2.0 bench top freeze dryer. The vial content was first frozen to −20
°C and then left to dry at 16 Pa using a condenser temperature
of −86 °C.
Particle Characterization
Confocal Laser Scanning Microscopy
The particle morphology
was visualized using the Bio-Rad RAD200 confocal laser scanning system
mounted on the Nikon Eclipse TE300 inverted microscope and connected
to a computer running Zeiss LaserSharp 2000 software. A suspension
of dried particles was placed on a microscope slide and excited with
an argon laser at 488 nm and helium-neon laser at 543 nm. To enhance
the observation of the polymer–drug distribution, the total
emission was divided into two images that were captured by using two
separate photomultiplier tubes (PMTs): PMT1 captured fluorescence
at 515 ± 30 nm (green region) and PMT2 captured fluorescence
above 570 nm (yellow-red region).
Scanning Electron Microscopy
Benchtop scanning electron
microscopy (SEM) (model TM3030, Hitachi) was utilized to investigate
the surface morphology of the particles and the efficiency of the
washing process. All micrographs were taken with an aperture size
of 30 μm using a beam current of 2.1 nA and a voltage of 10
kV. The washing was considered successful if no PVA crystals could
be found on SEM images and no PVA film bridges between the particles.
Particles with a smooth clean surface and no sign of particle–particle
bridges were considered properly washed.
Focused Ion Beam-Scanning Electron Microscopy
This
imaging was carried out using a dual-beam focused ion beam-scanning
electron microscope (FIB-SEM) instrument (Nova 600 NanoLab, FEI Company,
Hillsboro, Oregon, USA), which combines ultra-high-resolution SEM
and precise FIB etching and deposition. The FIB acceleration voltage
was 30 kV, and the ion beam current was 20 nA. The cross section was
cleaned at 7 nA with the final cleaning at 3 nA. To preserve the exposed
cross-section surface during imaging at 2 min/image, the current was
reduced to 30 pA.
X-ray Diffraction Spectroscopy
X-ray diffraction spectroscopy
(XRD) patterns of raw SRL, blank PLGA particles, raw PLGA, and SRL-loaded
PLGA particles (1:1 SRL/PLGA blend) were recorded using a Bruker D2
Phaser diffractometer equipped with a one-dimensional LYNXEYE detector.
The samples were exposed to Cu Kα (1.54184 Å) radiation
(30 kV, 10 mA) passed through a 0.5 mm thick nickel filter over the
2θ range from 2 to 40°, with a step size of 0.02°
and a rotation speed of 15 rpm. The spectra were obtained using Bruker’s
proprietary EVA 2.0 software. Triple runs were performed for each
sample for reproducibility.
Attenuated Total Reflection–Fourier Transform Infrared
Spectroscopy
Attenuated total reflection–Fourier transform
infrared (ATR–FTIR) analysis was carried out using the Thermo
Fisher Scientific Nicolet iS50 FTIR spectrometer. Between 2 and 3
mg of the powdered sample was placed onto the universal diamond ATR
top-plate, and the spectrum was recorded within 32 s over the range
of 4000–400 cm–1.
Drug Release Study
A 100 mL of dissolution medium was
prepared in a volumetric flask by mixing 10 mL of 20 vol % Tween 20
solution, 10 mL of absolute ethanol (200 proof), 25.9 mL of 5.8 M N,N-diethylnicotinamide (DENA), 44.1 mL
of Milli-Q water, and 10 mL of 10× phosphate-buffered saline
at 37 °C for 1 h. To measure the SRL release profile, 2 mg of
freeze-dried particles was placed into a microcentrifuge tube, and
2 mL of the dissolution medium was added. The tube was capped, alternately
sonicated, and vortex-agitated for 2 min to break apart any particle
aggregates and then placed in an agitator and incubated at 37 °C
and 250 rpm for 25 min. After that, the tube was centrifuged for 5
min at 13,000 rpm. The supernatant was extracted from the sample using
a syringe and transferred into a labeled high performance liquid chromatography
(HPLC) vial. The removed supernatant was replenished with fresh dissolution
medium, and the same procedure was repeated for the samples collected
after 1, 2, 3, 4, 5, 7, and 24 h. After 24 h, the remaining sample
was quenched by adding 2 mL of acetonitrile (ACN) to fully dissolve
drug-deprived particles and release the remaining drug. All samples
were stored at −20 °C before analysis. The concentration
of SRL in the samples was determined by HPLC (Agilent Technologies,
1100 series, Hewlett Packard) using the procedure described elsewhere,[32] based on the calibration line shown in Figure S4.
Results and Discussion
Mean Droplet/Particle Size
Table summarizes the droplet/particle sizes and
their CVs for each run. The mean droplet diameter (D̅d) in the dripping regime was varied from 5.2 to 13.8
to 23.5 μm by changing the depth of MCs, DMC, from 2 to 4 to 5 μm (samples S1–S3). The ratio
of D̅d to the hydraulic channel
diameter (dh) was 3.3–3.4 for DMC = 4 and 5 μm, which is close to the
droplet size to pore size ratio in SPG membrane emulsification.[33] For grooved MCs with trapezoidal cross section
and no terrace (LT = 0), D̅d/dh was around 3.0.[34] For LT > 0, D̅d/dh ranged
from just above 3 to 6, which is the maximum value that can be achieved
only for very long terraces. In this study, D̅d/dh values were within this
range at DMC = 4 and 5 μm.The mean particle size achieved in the chip with a channel depth
of 5, 4, and 2 μm was 8.5, 3.8, and 1.8 μm, respectively
(samples S1–S3). As a comparison, all commercial injectable,
long-acting PLGA-based depot formulations have a mean particle size
of at least 8 μm, such as Lupron Depot (∼8 μm),[35] Sandostatin LAR (∼50 μm),[36] Vivitrol (40–60 μm),[37] and Ozurdex (∼300 μm). These medicines
are injected either subcutaneously or intramuscularly using relatively
large needle diameters (19–23 gauge), due to broad particle-size
distributions, for example, the volume median diameter of the 1-month
Lupron Depot microspheres produced using the conventional emulsification—spray
drying technique is (11.4 ± 0.5) μm, but 10 vol % of the
particles are bigger than 30 μm, and the maximum particle size
is 100 μm.[38] These PLGA microspheres
are injected through a 23G needle with an inner diameter of 116 μm.
PLGA particles that could be administered using thinner needles would
make clinical use more patient-friendly because a reduced needle size
leads to reduced pain.[39] In this work,
the mean particle size in sample S1 was 8.5 μm, but 95% of the
particle sizes were in a very narrow range of 7.8–9.2 μm.
The minimum particle size in drug-eluting balloon (DEB) coatings is
about 1.5 μm, which corresponds to a drug release half-life
of about 14 days under physiological conditions. Smaller particle
sizes do not provide sufficiently extended drug release due to an
increased surface area to volume ratio and reduced diffusional pathway
for the drug.[12] The maximum particle size
in DEB coatings is approximately the size of a red blood cell, 6–8
μm,[12] to prevent embolization of
capillaries due to any release of the particles into the blood stream
during or after treatment.
Sustained Droplet Generation
During droplet generation,
the dispersed phase expands on the terrace into discs, as shown in Figure a, due to the confinement
in the vertical direction. The Laplace pressure of the dispersed phase
on the terrace is p1 = γ(1/r1 + 2/DMC), where
γ is the interfacial tension and r1 is the disc radius, as shown in Figure S2 in the Supporting Information. Confined droplets expand on the terrace
due to influx of the dispersed phase fluid, but p1 does not change because DMC ≪ r1 and p1 ≈ 2γ/DMC, that is,
the Laplace pressure on the terrace does not depend on the disc radius r1 but only on the terrace depth. When the dispersed
phase reaches the terrace edge and enters a well, it is no longer
confined in the orthogonal direction and expands in all directions.
The Laplace pressure in the well is p2 = γ/r2, where r2 is the droplet radius in the well, which is much greater
than DMC and thus p1 ≫ p2. The difference in
the Laplace pressure (p1–p2) induces a sudden flow of the dispersed phase
into the well, and the dispersed phase jet breaks via Rayleigh–Plateau
instability.[34]Video S1 in the Supporting Information shows that droplet generation
through the Laplace pressure induced a snap-off for sample S1. A confined
droplet expands on the terrace, and once it reaches the terrace edge,
the interface is quickly pulled into the well, where it releases a
droplet and then retraces back. This pinch-off mechanism requires
no shear force and occurs entirely due to a variable curvature of
the interface, which affects the Laplace pressure.[40] We have proved this feature by varying the CP flow rate
in the dripping regime, but it had no impact on the droplet size.
The droplet size was unaffected even when the CP flow rate was very
low (Video S2) or equal to zero, which
caused the formed droplets to accumulate under the cover glass and
self-assemble into densely packed single-layer or multi-layer hexagonal
arrays, as shown in Figure c,d.
Figure 2
Droplet generation in different chips: (a) CMS6-1 chip
after 1
h of continuous operation; (b) CMS6-1 chip after 24 h of continuous
operation; (c) CMS6-3 chip after 2 h of continuous operation; (d)
CMS6-2 chip after 2 h of continuous operation. Samples S1–S3
in Table .
Droplet generation in different chips: (a) CMS6-1 chip
after 1
h of continuous operation; (b) CMS6-1 chip after 24 h of continuous
operation; (c) CMS6-3 chip after 2 h of continuous operation; (d)
CMS6-2 chip after 2 h of continuous operation. Samples S1–S3
in Table .Cleaning of the chip using the described procedure
was very effective
and led to sustained droplet generation for at least 24 h. The change
in the contact angle of water during cleaning a silicon surface is
shown in Figure S1 in the Supporting Information. The contact angle of a Milli-Q water drop sitting on a contaminated
silicon surface was ∼60° (Figure S1a). After washing the chip with DCM, the contact angle was reduced
to 32.4° (Figure S1b) due to partial
removal of organic contaminants. After complete removal of the persistent
organic layer by plasma oxidation, the contact angle was reduced to
16.9° (Figure S1c), which means that
the silicon surface was highly hydrophilic.Droplet generation
pictures in the CMS6-1 chip after continuous
operation for 1 and 24 h are compared in Figure a,b. Although the wall wettability and droplet
shapes on the terrace were slightly altered after 24 h due to prolonged
contact of the silicon surface with emulsion ingredients (DCM, SRL,
and PVA), no significant change in the droplet size was observed.
Any wetting of the terrace walls by the dispersed phase reduces the
Laplace pressure on the terrace (p1),
and its radius of curvature becomes greater than DMC/2. In the limiting case, for a wetting angle of 90°,
the radius of curvature approaches infinity, and the Laplace pressure
gradient tends to zero. This leads to negligible driving force for
droplet pinch-off and causes a continuous outflow of the dispersed
phase from the channels and formation of big polydisperse droplets.[41]Long-term droplet production stability
in the CMS6-2 chip was compared
for samples S2 and S5 and is shown in Table . As can be seen, the mean droplet size after
24 and 48 h was the same (13.8 μm), but the CV increased slightly
from 2.5% after 24 h to 3% after 48 h. The mean droplet size in different
chips was measured for extended periods of time with the results shown
in Figure . The temporal
fluctuations of droplet sizes from different terraces in the CMS6-1
chip are shown in Figure a. The droplet size variations between different terraces
were below 1.5 μm, and a mean droplet size of 23.5 μm
was stable over time. In addition, 89–95% of all MCs in the
chip was actively producing droplets at any time, and all channels
were active at a certain time during the investigated period.
Figure 3
(a) Mean droplet
diameter in the CMS6-1 chip at different terraces
over 25 h; (b) mean droplet diameter (bars) and CV (solid line) in
the CMS6-2 chip over 24 h; (c) mean droplet dimeter (bars) and CV
(solid line) in the CMS6-3 chip over 20 h; (d) confocal laser scanning
microscopy (CLSM) images of SRL-loaded PLGA particles fabricated in
runs S1 (i), S2 (ii), and S3 (iii) in Table .
(a) Mean droplet
diameter in the CMS6-1 chip at different terraces
over 25 h; (b) mean droplet diameter (bars) and CV (solid line) in
the CMS6-2 chip over 24 h; (c) mean droplet dimeter (bars) and CV
(solid line) in the CMS6-3 chip over 20 h; (d) confocal laser scanning
microscopy (CLSM) images of SRL-loaded PLGA particles fabricated in
runs S1 (i), S2 (ii), and S3 (iii) in Table .The droplet generation regime shifts from the dripping
regime (small
and uniform drops) to the continuous outflow regime (large and non-uniform
drops) at the critical dispersed-phase velocity, which depends on
channel geometry, interfacial tension, and the viscosity ratio between
the two phases.[42] When triolein droplets
were generated in a 1 wt % sodium dodecyl sulfate solution, the critical
velocity in grooved channels with the similar geometry was 2.2 mm/s.[41] In the S1 experiment, the average velocity in
MCs was 4.2 mm/s, but the dripping regime still existed. It can be
explained by the fact that DCM is less viscous than triolein, and
the critical velocity is higher at lower dispersed-phase viscosity.Similar studies were carried out in CMS6-2 and CMS6-3 chips, and
the results are shown in Figure b,c, respectively. Due to their smaller channels, droplet
sizes generated by these chips were smaller than those in the CMS6-1
chip. For the CMS6-2 chip, the 90% confidence interval of the mean
droplet size was (13.8 ± 0.6) μm with CV = 2.5%. According
to the National Institute of Standards and Technology, particles are
monodispersed if at least 90% of the particles have a size within
5% of the median size, D̅d. For
normal size distribution, 90% of the particle sizes is within 1.64
standard deviations (σ) of the mean. Thus, droplets are monodispersed
if 1.64σ ≤ 0.05D̅d or
CV ≤ 3%. Therefore, the 90% confidence limits of the mean for
monodisperse droplets should be (13.8 ± 0.7) μm. In the
CMS6-3 chip, the 90% confidence interval of the mean droplet size
was (5.2 ± 0.3) μm with a CV of 3.5%. The fact that CV
> 3% can be attributed to the larger error in measuring the size
of
smaller droplets.
Particle Washing
The final product will be contaminated
with PVA if particles are not washed. PVA is GRAS by the FDA. Also,
the European Food Safety Authority (EFSA) has approved the use of
PVA as a food additive if the total intake of PVA does not exceed
4.8 mg/kg bw/day. However, residual PVA can affect bulk properties
of the product and should be removed. In the first place, the PVA
concentration in the CP should be minimized in order to reduce the
initial level of PVA contamination and the number of washing cycles
required. It was found that the PVA concentration in the aqueous phase
could be reduced from 1.5 to 1 wt % without noticeable impact on the
mean droplet size and CV value (S5 and S6 samples in Table ). The reduction in the PVA
concentration below 1 wt % had a negative impact on the droplet size
uniformity (the data are not shown here).Hence, the washing
procedure was investigated using sample S1 but the PVA concentration
in the CP was reduced from 1.5 to 1 wt %. We have tried to quantify
the amount of PVA in the supernatant by UV–vis spectroscopy
by measuring the height of the absorbance peak at 280 nm, which was
reduced with an increase in the number of washing cycles. The UV–vis
analysis of standard solutions of PVA in the concentration range of
0.5–5 wt % revealed that the height of the adsorption peak
at 280 nm was proportional to the PVA concentration in the solution
(Figure S3 in the Supporting Information). Although the UV–vis spectra clearly show that the supernatant
was increasingly less turbid, the method could not be used to quantify
the concentration of residual PVA in the supernatant because the supernatant
peak after 2nd, 3rd, 4th, and 5th wash was much higher than the peak
for pure 1 wt % PVA solution, as shown in Figure a,b. It was probably caused due to interference
from tiny particle debris in the supernatant, released during washing,
that can absorb more UV light than dissolved PVA molecules. The peak
at 280 nm almost completely disappeared after 6 cycles. SEM imaging
was carried out to confirm the effectiveness of the washing procedure,
as shown in Figure c–e. As shown in Figure c, unwashed particles were aggregated due to binding
by the PVA film deposited between dried particles. The formation of
particle clusters through PVA bridges can alter all particle size-dependent
properties of the product, such as syringe ability, dispersibility
in the secondary polymer matrix, and drug release rate. After eight
washes, the particle surface was clean and smooth, without any visible
PVA film, as shown in Figure d,e. However, a small fraction of PVA probably remains on
the particle surface because PVA forms an interconnected network with
PLGA,[43] which cannot be washed away from
the surface. The amount of molecularly bound PVA is too small to be
quantified, and it does not affect the particle size distribution.
However, the particle interactions with cell membranes in the body
can be affected due to a different chemistry of the surface. The amount
of residual PVA adsorbed on the particle surface depends on the miscibility
of the organic solvent with water. A higher amount of adsorbed PVA
can be expected in the particles prepared from the solvent blend with
a higher amount of IPAc due to higher solubility of IPAc in water
compared to DCM.
Figure 4
Effect of the number of washing cycles on the purity of
the supernatant
and particle morphology for the sample S2: (a) UV–visible absorption
spectra of the supernatant after each washing cycle and for 1 wt %
PVA solution; (b) equivalent PVA concentration of the supernatant
as a function of the number of washing cycles (the PVA concentrations
in the plot are estimated from the heights of the UV–vis peak
at 280 nm based on the assumption that the supernatant is a pure PVA
solution); (c) SEM image of SRL-loaded PLGA particles without washing;
and (d,e) SEM images of the same sample after eight washes.
Effect of the number of washing cycles on the purity of
the supernatant
and particle morphology for the sample S2: (a) UV–visible absorption
spectra of the supernatant after each washing cycle and for 1 wt %
PVA solution; (b) equivalent PVA concentration of the supernatant
as a function of the number of washing cycles (the PVA concentrations
in the plot are estimated from the heights of the UV–vis peak
at 280 nm based on the assumption that the supernatant is a pure PVA
solution); (c) SEM image of SRL-loaded PLGA particles without washing;
and (d,e) SEM images of the same sample after eight washes.
Solvent Evaporation and Freeze Drying
The size and
morphology of drug-loaded particles depend on the droplet size, emulsion
formulation, and solvent evaporation rate. The solvent evaporation
rate can be controlled by adjusting the temperature and the degree
of pre-saturation of the CP with the organic solvent. Two different
batches of sample S1 were produced using PVA solutions with different
degrees of IPAc saturation (Table ).
Table 3
Mean Particle Size before and after
Freeze Dryinga
before
freeze drying
after
freeze drying
sample
mean size (μm)
CV (%)
mean size
(μm)
CV (%)
S1A
7.5
5.3
6.7
4.3
S1B
9.6
6.2
8.1
5.0
The CP was 1.5 wt % PVA saturated
with IPAc (S1A) or pure 1.5 wt % PVA solution (S1B).
The CP was 1.5 wt % PVA saturated
with IPAc (S1A) or pure 1.5 wt % PVA solution (S1B).For batch A, the CP was 1.5 wt % PVA solution pre-saturated
with
IPAc, while for batch B the CP was pure 1.5 wt % PVA solution, thereby
enabling higher rates of solvent extraction from the droplets. In
both cases, the initial droplet size was 22 μm with a CV of
4.7%, but larger particles were formed by faster solvent removal,
as shown in S1B batch in Table . The particle size in both batches was above 7 μm,
which is the theoretical prediction from the mass balance equation
based on a completely non-porous solid matrix. The total specific
volume of a solid polymer is the sum of the volume occupied by the
polymeric chains and the free volume of the material. If an organic
solvent is rapidly removed from the droplets, the result will be the
formation of excess free volume trapped due to rapid solvent removal
that can be reduced either slowly through physical aging or more rapidly
through freeze drying. The particle size in both samples shrank by
10–15% following freeze drying and was close to the size predicted
by eq . As can be seen
in Figure , SRL was
more uniformly distributed when the CP was a pure PVA solution, as
shown in Figure a2–d2,
probably due to faster solvent removal and insufficient time for drug–polymer
phase separation. When the CP was pre-saturated with IPAc, a phase
boundary between the drug and the polymer could be observed, as shown
in Figure a1–d1.
Figure 5
Effect
of saturating the CP with the organic solvent on the particle
morphology. (a1,a2): CLSM images of particles before freeze drying;
(b1,b2): CLSM images of particles after freeze drying; (c1,c2): SEM
images of intact particles and the schematic view of their internal
structure; (d1,d2): SEM images of particles cross-sectioned by FIB.
The CP was 1.5 wt % PVA solution saturated by IPAc in (a1–d1)
and pure 1.5 wt % PVA solution, in (a2–d2). In (a1,b1), the
brighter particle parts are rich in SRL and the darker parts are rich
in PLGA. The drug loading in all particles was 33 wt %.
Effect
of saturating the CP with the organic solvent on the particle
morphology. (a1,a2): CLSM images of particles before freeze drying;
(b1,b2): CLSM images of particles after freeze drying; (c1,c2): SEM
images of intact particles and the schematic view of their internal
structure; (d1,d2): SEM images of particles cross-sectioned by FIB.
The CP was 1.5 wt % PVA solution saturated by IPAc in (a1–d1)
and pure 1.5 wt % PVA solution, in (a2–d2). In (a1,b1), the
brighter particle parts are rich in SRL and the darker parts are rich
in PLGA. The drug loading in all particles was 33 wt %.Initially, SRL and PLGA are fully mixed within
the newly formed
droplets due to the entropic gain (ΔSM > 0), as a result of their random distribution in the organic
phase
and favorable solvent-PLGA and solvent-SRL interactions (ΔHM < 0), resulting in a negative Gibbs free
energy of mixing, ΔGM < 0, where
ΔGM = ΔHM – TΔSM. As both solvents are removed, the concentration of SRL and
PLGA increases and the entropic gain becomes insufficient to overcome
the enthalpic penalty (ΔHM >
0)
due to disfavored PLGA–SRL interactions, which are more pronounced
in more concentrated solutions. As a result, a homogeneous organic
phase is separated into polymer-rich and drug-rich domains in the
process of spinodal decomposition. Further solvent removal causes
segregation of SRL-rich domains and formation of Janus particles with
a single crescent-moon-shaped SRL-rich region on one side of the particle,
as shown in Figure c1. This step is possible only if the solvent is removed sufficiently
slowly. Nile red is a hydrophobic compound whose fluorescence is stronger
in less polar environments.[44] SRL-rich
regions are less polar than PLGA-rich regions, and therefore, they
exhibit a higher fluorescence intensity with brighter red color as
shown in Figure b1.
Since the drug loading was 33%, a SRL-rich region occupies smaller
particle volume than a PLGA-rich region. The phase separation is incomplete,
and both regions contain both components. Indeed, as shown in the
FIB-SEM image in Figure d1, drug patches are embedded within the PLGA region, while PLGA
patches are incorporated within the SRL region.An observation
that faster solvent removal from droplets leads
to incomplete segregation of SRL and PLGA and more uniform drug distribution
in the polymer matrix is consistent with the results of our previous
study, where composite PCL–PLA particles were produced by emulsification—solvent
evaporation using the dispersed phase composed of a mixture of ethyl
acetate (partially soluble in water) and DCM (insoluble in water).
More uniform polymer distribution in the particles was observed when
the dispersed phase contained more ethyl acetate.[45]
Effect of Drug Loading
The effect of drug loading on
the particle morphology is shown in Figure . The extent of drug–polymer phase
separation depended on the drug loading and ranged from a uniform
drug distribution for the drug loadings of 33 and 42 wt %, as shown
in Figure (i,ii),
to small uniform SRL patches embedded within a PLGA matrix for a drug
loading of 44 wt %, as shown in Figure (iii), to patchy Janus particles for the drug loading
from 46 to 50 wt %, as shown in Figure (iv–vi). Homogeneous particles are preferred
since they are more resistant to attrition during the coating process
due to their smooth surface and regular spherical shape with no internal
interfaces that can cause particle breakage. Apart from the drug loading
in the particles, the amount of drug in the coating can be tailored
by the particle concentration in the coating suspension, which can
vary between 10 and 65 wt % to provide the amount of SRL on the expandable
portion of the catheter surface from 1 to 10 μg/mm.[12]
Figure 6
Effect of drug loading on the particle morphology. The
drug loading
was: (i) 33 wt % (S4); (ii) 42 wt % (S5); (iii) 44 wt % (S6); (iv)
45 wt % (S7); (v) 46 wt % (S8); and (vi) 50 wt % (S9). The experimental
conditions and emulsion formulations are shown in Table . The fluorescence microscopy
images are taken at 20× (A) and 60× (B) magnification. The
SEM images of the particles are shown in (C), and the schemes of particle
morphologies are shown in (D).
Effect of drug loading on the particle morphology. The
drug loading
was: (i) 33 wt % (S4); (ii) 42 wt % (S5); (iii) 44 wt % (S6); (iv)
45 wt % (S7); (v) 46 wt % (S8); and (vi) 50 wt % (S9). The experimental
conditions and emulsion formulations are shown in Table . The fluorescence microscopy
images are taken at 20× (A) and 60× (B) magnification. The
SEM images of the particles are shown in (C), and the schemes of particle
morphologies are shown in (D).Patchy and patchy Janus particles are not stable
during storage
in aqueous solutions and slowly evolve into fully separated Janus
morphology due to Ostwald ripening. In this process, drug from small
patches is dissolved into the surrounding aqueous phase and deposited
onto larger patches. The process also occurs at a later stage of the
solvent evaporation process through internal diffusion of SRL facilitated
by the residual solvent. The similar patch coarsening process occurred
in PCL–PLA composite particles leading to various particle
morphologies.[46]
Microparticle Characterization
XRD analysis was carried
out on freeze-dried S4 microparticles to reveal the presence of any
impurities in the sample and assess its crystallinity. The XRD patterns
of raw SRL powder, raw PLGA powder, blank PLGA particles produced
from the dispersed phase containing 4 wt % PLGA and SRL-loaded PLGA
particles with 33% drug loading produced from the dispersed phase
containing 4 wt % total solids (sample S4) are shown in Figure a. A series of sharp and well-defined
SRL peaks at 2θ values between 7 and 25° reveal a crystalline
structure of SRL and can be attributed to X-ray diffraction from different
lattice planes in SRL crystallites. A large amorphous hump between
2θ values of 8 and 26° was observed for raw PLGA powder
due to the absence of regular atomic structures in the amorphous polymer.
A very shallow and broad peak of blank PLGA particles indicates that
these particles are more amorphous than raw PLGA powder, probably
due to random supramolecular rearrangement of PLGA chains following
solvent evaporation. However, a more prominent peak of SRL-loaded
PLGA particles compared to blank PLGA particles indicates their more
crystalline structure owing to the drug entrapment within a polymer
matrix. Therefore, encapsulation of SRL within PLGA can be confirmed
by XRD analysis. The absence of sharp peaks in the XRD pattern of
SRL-loaded PLGA particles indicates that SRL was either molecularly
dispersed in PLGA or present in the form of amorphous domains.
Figure 7
(a) XRD patterns
of raw SRL powder, raw PLGA powder, SRL-loaded
PLGA particles (sample S4), and blank PLGA particles; (b) ATR–FTIR
spectra of raw SRL powder, raw PLGA powder, and SRL-loaded particles
(sample S4).
(a) XRD patterns
of raw SRL powder, raw PLGA powder, SRL-loaded
PLGA particles (sample S4), and blank PLGA particles; (b) ATR–FTIR
spectra of raw SRL powder, raw PLGA powder, and SRL-loaded particles
(sample S4).Figure b shows
FTIR spectra for pure PLGA, pure drug, and drug-loaded PLGA particles.
Observed IR absorption peaks reveal the presence of characteristic
bonds in PLGA and SRL. For example, the peaks at ∼1000 (1)
and 1640 cm–1 (3) for SRL were due to the out-of-plane
C–H bending vibrations in −CH=CH– bonds
and the C=C stretching vibrations, respectively. These two
bonds do not exist in PLGA, and consequently, no peaks were found
in the PLGA spectrum at these frequencies. On the other hand, strong
peaks at ∼1100 (2) and 1750 cm–1 (4) for
PLGA occurred due to the C–O–C and C=O stretching
vibrations in ester groups, respectively. In addition, the peak at
∼3400 cm–1 (5) for SRL was due to the O–H
stretching vibrations. In PLGA macromolecules, the O–H bonds
are present only in terminal groups. Also, Figure b shows that SRL was incorporated uniformly
within the particles rather than being separated onto the surface
of the particles since the peaks (1), (3), and (5) are negligible
for SRL-loaded PLGA particles.
In Vitro Drug Release Study
The percentage of drug
released over 24 h from PLGA particles with a size of 5.2 μm
loaded with 33 wt % SRL is shown in Figure . No difference in release kinetics between
two replicates was observed, indicating a high batch-to-batch consistency
of the release profile due to consistent particle size and structure.
The duration of drug release in injectable, clinical, long-acting
PLGA-based depot formulations typically ranges from 1 week to 6 months.[15] In the case of DEB applications, since the resolution
of inflammation in the region of balloon dilation typically takes
4–12 weeks, it is desirable to provide therapeutic tissue levels
of the drug for about 4 to 12 weeks following the treatment.[12] To reduce the duration of drug release during
in vitro testing, as shown in Figure , the drug release rate was enhanced by adding DENA,
which acts as an effective hydrotrope (non-micellar solubilizer) of
poorly water-soluble drugs. For example, the aqueous solubility of
paclitaxel from PLGA particles was increased by several orders of
magnitude in the presence of DENA.[47] It
has been explained either by faster degradation of PLGA in the presence
of DENA[47] due to hydrolysis of ester bonds
in PLGA chains[48] or by higher drug solubility
due to DENA’s non-stoichiometric accumulation around the drug.[49]
Figure 8
Percentage of SRL released from PLGA particles as a function
of
time under accelerated conditions for two replicate determinations
on sample S3 (Table ). After 24 h, all particles in the sample were dissolved with ACN.
Percentage of SRL released from PLGA particles as a function
of
time under accelerated conditions for two replicate determinations
on sample S3 (Table ). After 24 h, all particles in the sample were dissolved with ACN.Most long-acting PLGA-based depot formulations
exhibit an initial
burst release which often releases a quarter of the total drug on
the first day. As a result, the drug concentration on the first day
of administration is often 100 times higher than the steady state
drug concentration in the blood.[15] In this
study, nearly 15% of encapsulated drug was released within the first
2 h by the initial burst release. The cause of the initial burst release
is still not fully understood, but it can be attributed to the diffusion
of drug molecules from the surface layer of the microparticles. As
shown in Figure ,
the initial burst release was followed by zero-order kinetics (the
constant release rate) from 2 to 24 h, during which the cumulative
amount of the released drug reached 29%. After 24 h, 71% of the drug
was still entrapped in the particles and was released by quenching
the particles with ACN. In the steady-state release period, the drug
depletion from the particles was counterbalanced by an increased permeability
of the particle matrix due to DENA-induced PLGA degradation leading
to a constant release rate of SRL. Increased permeability of the polymer
matrix is a result of the decrease in the average molecular weight
of the polymer due to PLGA hydrolysis and reduced degree of polymer
chain entanglements. Thus, the mobility of PLGA chains increases,
leading to increased matrix permeability to SRL, according to the
free volume theory of diffusion.[48]
Conclusions
Monodispersed SRL-loaded PLGA microspheres
of controlled size and
internal morphology were successfully produced by microfluidic step
emulsification and subsequent solvent evaporation. A stable droplet
generation in the dripping regime was maintained for 48 h and resulted
in droplets of highly consistent size created across all MC terraces.
The droplet size in the dripping regime was controlled by the smallest
dimension of droplet forming MC, confirming that droplet pinch-off
was driven by the gradient of the capillary pressure established when
a deformed droplet squeezed in a shallow MC enters a deep microfluidic
well.The size of the generated microspheres was accurately
predicted
from the dispersed phase formulation and the size of the parent droplets.
The microspheres were small enough and highly monodispersed to be
safely injected in the blood stream using hypodermic needles of any
size and can be used as drug delivery coatings for implantable medical
devices, such as cardiac stents and balloon catheters.The particle
morphology has a profound effect on the drug release
rate[50,51] with less significant burst release expected
to occur from microspheres with a more homogeneous internal structure.
In this study, the degree of drug–polymer phase separation
was controlled by varying the drug to polymer ratio in the microspheres
and the rate of solvent removal. Suppressed solvent evaporation and
higher drug loadings led to more pronounced polymer–drug phase
separation, resulting in heterogeneous patchy, patchy Janus, and Janus
particle morphologies.The developed accelerated drug release
testing method allowed us
to release nearly 30% of SRL within 24 h, with the initial bust release
consuming nearly a quarter of the drug initially present in the microspheres.To conclude, monodispersed SRL-loaded PLGA microspheres generated
by step microfluidic emulsification/solvent evaporation can open up
new routes for the manufacturing of more effective implantable devices
and for the development of improved subcutaneous drug injection methods
for restenosis treatment. More broadly, the proposed microfluidic
approach for the reliable, robust, and scalable manufacturing of highly-monodisperse
drug-loaded microparticles could be extended to other excipient/drug
formulations, hence improving the performance of many other subcutaneous
drug treatments and implantable devices for controlled drug release.In the next phase of this study, the fabricated microspheres will
be dispersed in a hydrocarbon or fluorocarbon solution to form the
coating formulation that will be applied to the surface of a balloon
catheter and let dry to form the coating. After that, the coated device
will be used to assess the drug transfer to an arterial vessel.
Authors: Bernardo Cortese; Gaetano di Palma; Roberto A Latini; Mostafa Elwany; Pedro Silva Orrego; Romano G Seregni Journal: Cardiovasc Revasc Med Date: 2017-03-25
Authors: Julie A Straub; Donald E Chickering; Charles C Church; Bhavdeep Shah; Thomas Hanlon; Howard Bernstein Journal: J Control Release Date: 2005-08-29 Impact factor: 9.776