Literature DB >> 23117022

Recent advances in drug eluting stents.

Amey S Puranik1, Eileen R Dawson, Nicholas A Peppas.   

Abstract

One of the most common medical interventions to reopen an occluded vessel is the implantation of a coronary stent. While this method of treatment is effective initially, restenosis, or the re-narrowing of the artery frequently occurs largely due to neointimal hyperplasia of smooth muscle cells. Drug eluting stents were developed in order to provide local, site-specific, controlled release of drugs that can inhibit neointima formation. By implementing a controlled release delivery system it may be possible to control the time release of the pharmacological factors and thus be able to bypass some of the critical events associated with stent hyperplasia and prevent the need for subsequent intervention. However, since the advent of first-generation drug eluting stents, long-term adverse effects have raised concerns regarding their safety. These limitations in safety and efficacy have triggered considerable research in developing biodegradable stents and more potent drug delivery systems. In this review, we shed light on the current state-of-the-art in drug eluting stents, problems related to them and highlight some of the ongoing research in this area.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23117022      PMCID: PMC3567608          DOI: 10.1016/j.ijpharm.2012.10.029

Source DB:  PubMed          Journal:  Int J Pharm        ISSN: 0378-5173            Impact factor:   5.875


  103 in total

Review 1.  In-stent stenosis: pathology and implications for the development of drug eluting stents.

Authors:  Martin R Bennett
Journal:  Heart       Date:  2003-02       Impact factor: 5.994

2.  Angiographic patterns of restenosis after paclitaxel-eluting stent implantation.

Authors:  Ioannis Iakovou; Thomas Schmidt; Lei Ge; Giuseppe M Sangiorgi; Goran Stankovic; Flavio Airoldi; Alaide Chieffo; Matteo Montorfano; Mauro Carlino; Iassen Michev; Nicola Corvaja; John Cosgrave; Ulrich Gerckens; Eberhard Grube; Antonio Colombo
Journal:  J Am Coll Cardiol       Date:  2005-03-01       Impact factor: 24.094

3.  Frequency of and risk factors for stent thrombosis after drug-eluting stent implantation during long-term follow-up.

Authors:  Duk-Woo Park; Seong-Wook Park; Kyoung-Ha Park; Bong-Ki Lee; Young-Hak Kim; Cheol Whan Lee; Myeong-Ki Hong; Jae-Joong Kim; Seung-Jung Park
Journal:  Am J Cardiol       Date:  2006-06-12       Impact factor: 2.778

4.  Evaluation of the Medtronic (Driver) cobalt-chromium alloy coronary stent system.

Authors:  Michael H Sketch; Michael Ball; Barry Rutherford; Jeffrey J Popma; Catherine Russell; Dean J Kereiakes
Journal:  Am J Cardiol       Date:  2005-01-01       Impact factor: 2.778

Review 5.  Stent thrombosis of drug eluting stent: pathological perspective.

Authors:  Gaku Nakazawa
Journal:  J Cardiol       Date:  2011-08-11       Impact factor: 3.159

Review 6.  Drug-eluting stents: results, promises and problems.

Authors:  Barend L van der Hoeven; Nuno M M Pires; Hazem M Warda; Pranobe V Oemrawsingh; Bart J M van Vlijmen; Paul H A Quax; Martin J Schalij; Ernst E van der Wall; J Wouter Jukema
Journal:  Int J Cardiol       Date:  2005-03-10       Impact factor: 4.164

7.  Expandable intraluminal graft: a preliminary study. Work in progress.

Authors:  J C Palmaz; R R Sibbitt; S R Reuter; F O Tio; W J Rice
Journal:  Radiology       Date:  1985-07       Impact factor: 11.105

8.  Heparin-coated Wiktor stents in human coronary arteries (MENTOR trial). MENTOR Trial Investigators.

Authors:  M C Vrolix; V M Legrand; J H Reiber; G Grollier; M J Schalij; P Brunel; L Martinez-Elbal; M Gomez-Recio; F W Bär; M E Bertrand; A Colombo; J Brachman
Journal:  Am J Cardiol       Date:  2000-08-15       Impact factor: 2.778

9.  Distribution of glycosaminoglycans in consecutive layers of the rabbit aorta.

Authors:  T A Massaro; C E Glatz; N A Peppas; G M Chisolm; C K Colton
Journal:  Artery       Date:  1979-01

10.  Comparison of in vivo acute stent recoil between the bioabsorbable everolimus-eluting coronary stent and the everolimus-eluting cobalt chromium coronary stent: insights from the ABSORB and SPIRIT trials.

Authors:  Shuzou Tanimoto; Patrick W Serruys; Leif Thuesen; Dariusz Dudek; Bernard de Bruyne; Bernard Chevalier; John A Ormiston
Journal:  Catheter Cardiovasc Interv       Date:  2007-10-01       Impact factor: 2.692

View more
  28 in total

1.  Bioclickable and mussel adhesive peptide mimics for engineering vascular stent surfaces.

Authors:  Zhilu Yang; Xin Zhao; Rui Hao; Qiufen Tu; Xiaohua Tian; Yu Xiao; Kaiqing Xiong; Miao Wang; Yonghai Feng; Nan Huang; Guoqing Pan
Journal:  Proc Natl Acad Sci U S A       Date:  2020-06-29       Impact factor: 11.205

2.  Enhanced biocompatibility of CD47-functionalized vascular stents.

Authors:  Joshua B Slee; Ivan S Alferiev; Chandrasekaran Nagaswami; John W Weisel; Robert J Levy; Ilia Fishbein; Stanley J Stachelek
Journal:  Biomaterials       Date:  2016-02-08       Impact factor: 12.479

Review 3.  The Newest Generation of Drug-eluting Stents and Beyond.

Authors:  Dae-Hyun Lee; Jose M de la Torre Hernandez
Journal:  Eur Cardiol       Date:  2018-08

Review 4.  Drug-eluting coronary stents: insights from preclinical and pathology studies.

Authors:  Sho Torii; Hiroyuki Jinnouchi; Atsushi Sakamoto; Matthew Kutyna; Anne Cornelissen; Salome Kuntz; Liang Guo; Hiroyoshi Mori; Emanuel Harari; Ka Hyun Paek; Raquel Fernandez; Diljon Chahal; Maria E Romero; Frank D Kolodgie; Anuj Gupta; Renu Virmani; Aloke V Finn
Journal:  Nat Rev Cardiol       Date:  2019-07-25       Impact factor: 32.419

5.  HUCMNCs protect vascular endothelium and prevent ISR after endovascular interventional therapy for vascular diseases in T2DM rabbits.

Authors:  Haixia Ding; Tong Zhang; Yaping Du; Bei Liu; Yueqin Liu; Fujun Wang
Journal:  Mol Cell Biochem       Date:  2017-05-04       Impact factor: 3.396

6.  In Vitro and In Vivo Sustained Zero-Order Delivery of Rapamycin (Sirolimus) From a Biodegradable Intraocular Device.

Authors:  Kevin D Lance; Samuel D Good; Thaís S Mendes; Mynna Ishikiriyama; Patrick Chew; Laurel S Estes; Kazuhito Yamada; Sri Mudumba; Robert B Bhisitkul; Tejal A Desai
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-11       Impact factor: 4.799

7.  Enzyme Prodrug Therapy Engineered into Electrospun Fibers with Embedded Liposomes for Controlled, Localized Synthesis of Therapeutics.

Authors:  Rona Chandrawati; Morten T J Olesen; Thatiane C C Marini; Gurpal Bisra; Anne Géraldine Guex; Marcelo G de Oliveira; Alexander N Zelikin; Molly M Stevens
Journal:  Adv Healthc Mater       Date:  2017-07-12       Impact factor: 9.933

8.  Osstem Cardiotec Centum Stent Versus Xience Alpine Stent for De Novo Coronary Artery Lesion: A Multicenter, Randomized, Parallel-Designed, Single Blind Test.

Authors:  Chang-Hwan Yoon; Jihong Jang; Seung Ho Hur; Jun-Hee Lee; Seung Hwan Han; Soon-Jun Hong; Kiyuk Chang; In-Ho Chae
Journal:  Korean Circ J       Date:  2022-01-03       Impact factor: 3.101

9.  Heparin-Tagged PLA-PEG Copolymer-Encapsulated Biochanin A-Loaded (Mg/Al) LDH Nanoparticles Recommended for Non-Thrombogenic and Anti-Proliferative Stent Coating.

Authors:  Shivakalyani Adepu; Hongrong Luo; Seeram Ramakrishna
Journal:  Int J Mol Sci       Date:  2021-05-21       Impact factor: 5.923

10.  The Role of Biodegradable Poly-(L-lactide)-Based Polymers in Blood Cell Activation and Platelet-Monocyte Interaction.

Authors:  Anne Strohbach; Friedemann Maess; Katharina Wulf; Svea Petersen; Niels Grabow; Klaus-Peter Schmitz; Stephan B Felix; Raila Busch
Journal:  Int J Mol Sci       Date:  2021-06-13       Impact factor: 5.923

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.