Literature DB >> 35829793

Physical limits to human brain B0 shimming with spherical harmonics, engineering implications thereof.

Bruno Pinho Meneses1, Alexis Amadon2.   

Abstract

OBJECTIVE: As the MRI main magnetic field rises for improved signal-to-noise ratio, susceptibility-induced B0-inhomogeneity increases proportionally, aggravating related artifacts. Considering only susceptibility disparities between air and biological tissue, we explore the topological conditions for which perfect shimming could be performed in a Region of Interest (ROI) such as the human brain or part thereof.
MATERIALS AND METHODS: After theoretical considerations for perfect shimming, spherical harmonic (SH) shimming simulations of very high degree are performed, based on a 100-subject database of 1.7-mm-resolved brain fieldmaps acquired at 3T . In addition to the whole brain, shimmed ROIs include slabs targeting the prefrontal cortex, both or single temporal lobes, or spheres in the frontal brain above the nasal sinus. RESULTS AND DISCUSSION: We show "perfect" SH shimming is possible only if the ROI can be contained in a sphere that does not enclose sources of magnetic field inhomogeneity, which are gathered at the air-tissue interface. We establish a [Formula: see text]Hz inhomogeneity hard shim limit at 7T for whole brain SH shimming, that can only be attained at shimming degree higher than 90. On the other hand, under limited power and SH degree resources, 3D region-specific shimming is shown to greatly improve homogeneity in critical zones such as the prefrontal cortex and around ear canals.
© 2022. The Author(s), under exclusive licence to European Society for Magnetic Resonance in Medicine and Biology (ESMRMB).

Entities:  

Keywords:  B0 shimming; Human brain shimming; Magnetic resonance imaging; Shim coil design; Solid harmonics; Spherical harmonics; Susceptibility-induced inhomogeneity; Ultra-high field

Year:  2022        PMID: 35829793     DOI: 10.1007/s10334-022-01025-3

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.533


  25 in total

1.  Computer simulation studies of the effects of dynamic shimming on susceptibility artifacts in EPI at high field.

Authors:  Yansong Zhao; Adam W Anderson; John C Gore
Journal:  J Magn Reson       Date:  2005-03       Impact factor: 2.229

2.  Correction for geometric distortion in echo planar images from B0 field variations.

Authors:  P Jezzard; R S Balaban
Journal:  Magn Reson Med       Date:  1995-07       Impact factor: 4.668

3.  Design of a shim coil array matched to the human brain anatomy.

Authors:  Feng Jia; Hatem Elshatlawy; Ali Aghaeifar; Ying-Hua Chu; Yi-Cheng Hsu; Sebastian Littin; Stefan Kroboth; Huijun Yu; Philipp Amrein; Xiang Gao; Wenchao Yang; Pierre LeVan; Klaus Scheffler; Maxim Zaitsev
Journal:  Magn Reson Med       Date:  2019-09-30       Impact factor: 4.668

4.  Universal nonselective excitation and refocusing pulses with improved robustness to off-resonance for Magnetic Resonance Imaging at 7 Tesla with parallel transmission.

Authors:  L Van Damme; F Mauconduit; T Chambrion; N Boulant; V Gras
Journal:  Magn Reson Med       Date:  2020-08-04       Impact factor: 4.668

5.  A 32-channel multi-coil setup optimized for human brain shimming at 9.4T.

Authors:  Ali Aghaeifar; Jiazheng Zhou; Rahel Heule; Behzad Tabibian; Bernhard Schölkopf; Feng Jia; Maxim Zaitsev; Klaus Scheffler
Journal:  Magn Reson Med       Date:  2019-09-04       Impact factor: 4.668

6.  Susceptibility artefacts in NMR imaging.

Authors:  K M Lüdeke; P Röschmann; R Tischler
Journal:  Magn Reson Imaging       Date:  1985       Impact factor: 2.546

7.  Dynamic multi-coil shimming of the human brain at 7 T.

Authors:  Christoph Juchem; Terence W Nixon; Scott McIntyre; Vincent O Boer; Douglas L Rothman; Robin A de Graaf
Journal:  J Magn Reson       Date:  2011-07-23       Impact factor: 2.229

Review 8.  Twenty years of functional MRI: the science and the stories.

Authors:  Peter A Bandettini
Journal:  Neuroimage       Date:  2012-04-20       Impact factor: 6.556

9.  Dynamic multi-coil technique (DYNAMITE) shimming for echo-planar imaging of the human brain at 7 Tesla.

Authors:  Christoph Juchem; S Umesh Rudrapatna; Terence W Nixon; Robin A de Graaf
Journal:  Neuroimage       Date:  2014-11-08       Impact factor: 6.556

10.  In vivo human head MRI at 10.5T: A radiofrequency safety study and preliminary imaging results.

Authors:  Alireza Sadeghi-Tarakameh; Lance DelaBarre; Russell L Lagore; Angel Torrado-Carvajal; Xiaoping Wu; Andrea Grant; Gregor Adriany; Gregory J Metzger; Pierre-Francois Van de Moortele; Kamil Ugurbil; Ergin Atalar; Yigitcan Eryaman
Journal:  Magn Reson Med       Date:  2019-11-21       Impact factor: 4.668

View more
  1 in total

1.  Iterative static field map estimation for off-resonance correction in non-Cartesian susceptibility weighted imaging.

Authors:  Guillaume Daval-Frérot; Aurélien Massire; Boris Mailhe; Mariappan Nadar; Alexandre Vignaud; Philippe Ciuciu
Journal:  Magn Reson Med       Date:  2022-06-23       Impact factor: 3.737

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.