Literature DB >> 35813321

Reply to letter to the editor: "The iPad/iPhone 3D photography app-a promising device, but how about its accuracy?".

Yuming Chong1,2, Xinyu Liu2, Mai Shi3, Jiuzuo Huang1, Nanze Yu1, Xiao Long1.   

Abstract

Entities:  

Year:  2022        PMID: 35813321      PMCID: PMC9263771          DOI: 10.21037/atm-22-1324

Source DB:  PubMed          Journal:  Ann Transl Med        ISSN: 2305-5839


× No keyword cloud information.
We are happy to find your readers showed interest in our previous work entitled “Three-dimensional facial scanner in the hands of patients: validation of a novel application on iPad/iPhone for three-dimensional imaging” and left some valuable comments about it in a letter (1,2). By writing this response letter, the authors would like to thank them for their interest and discuss some important points they raised in their letter. Firstly, in the letter, Fan et al. kindly suggested using 3D images as the gold standard. Admittedly, a number of 3D imaging systems have been validated to have good accuracy, and direct measurement using caliper is time-consuming. However, measuring on a virtual model generated by a 3D imaging system is always an indirect method. The authors believe that the gold standard should be the measurement directly taken on subjects in the real world to avoid any possible distortion during imaging, and this is what many investigators did in their studies (3-5). Involuntary movement and soft tissue deformation are two major concerns in direct measurement. To address these problems, we recently consider the possibility of doing direct measurement on mannequin heads. Secondly, Vectra H2 is now available as the new generation of portable 3D imaging system. Accuracy study using Vectra H2 is necessary to make sure the new device is qualified in different patient populations. It is good advice to compare our novel imaging system with this new commercial device. Thirdly, the validation study aimed to test the accuracy of this novel imaging system in the entire face (1). There were two standards in choosing parameters. In the first place, they should be commonly-used parameters that cover the periorbital region, nasal region, and orolabial region; secondly, the parameters should include horizontal distances, vertical distances, and sagittal distances. Fan et al. put a good point that the novel system should undergo a more detailed validation study in the periorbital region (2). Further study using more specific periorbital landmarks will be conducted in the future. 3D imaging and stereophotography-based anthropometric measurements are important for the clinical practice of many departments. Improving the accuracy and portability of 3D scanners should always be a goal for researchers in this field. Hopefully, 3D imaging technology will continue to advance in the future. The article’s supplementary files as
  5 in total

1.  Accuracy and reliability of 3D stereophotogrammetry: A comparison to direct anthropometry and 2D photogrammetry.

Authors:  Furkan Dindaroğlu; Pınar Kutlu; Gökhan Serhat Duran; Serkan Görgülü; Erhan Aslan
Journal:  Angle Orthod       Date:  2015-08-12       Impact factor: 2.079

2.  Anthropometric precision and accuracy of digital three-dimensional photogrammetry: comparing the Genex and 3dMD imaging systems with one another and with direct anthropometry.

Authors:  Seth M Weinberg; Sybill Naidoo; Daniel P Govier; Rick A Martin; Alex A Kane; Mary L Marazita
Journal:  J Craniofac Surg       Date:  2006-05       Impact factor: 1.046

3.  Three-dimensional facial scanner in the hands of patients: validation of a novel application on iPad/iPhone for three-dimensional imaging.

Authors:  Yuming Chong; Xinyu Liu; Mai Shi; Jiuzuo Huang; Nanze Yu; Xiao Long
Journal:  Ann Transl Med       Date:  2021-07

4.  The iPad/iPhone 3D photography app-a promising device, but how about its accuracy?

Authors:  Wanlin Fan; Alexander C Rokohl; Yongwei Guo; Ludwig M Heindl
Journal:  Ann Transl Med       Date:  2022-06

5.  Validity and reproducibility of the 3D VECTRA photogrammetric surface imaging system for the maxillofacial anthropometric measurement on cleft patients.

Authors:  Siti A Othman; Lyddia Saffai; Wan N Wan Hassan
Journal:  Clin Oral Investig       Date:  2019-11-21       Impact factor: 3.573

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.