Literature DB >> 31754872

Validity and reproducibility of the 3D VECTRA photogrammetric surface imaging system for the maxillofacial anthropometric measurement on cleft patients.

Siti A Othman1,2, Lyddia Saffai3, Wan N Wan Hassan4,5.   

Abstract

OBJECTIVES: To validate the accuracy and reproducibility of linear measurements of three-dimensional (3D) images and to compare the measurements with the direct anthropometry method on cleft lip and palate (CLP) patients.
MATERIALS AND METHODS: Nineteen linear facial measurements were derived from 16 standardized surface landmarks obtained from 37 cleft patients (20 males, 17 females; mean age 23.84 years, standard deviation ± 6.02). They were taken manually with calipers and were compared with the digitally calculated distance on the 3D images captured using the VECTRA-M5 360° Imaging System with pre-marked landmarks. Another pair of 19 linear measurements were computed on the 3D images 2 weeks apart for intra- and inter-observer agreements. Statistical analyses used were paired t test, the Bland-Altman analysis, and the intra-class correlation coefficient (ICC) index.
RESULTS: Most of the linear measurements showed no statistically significant differences between the proposed method and direct anthropometry linear measurements. Nevertheless, bias of the 3D imaging system is present in the linear measurements of the nose width and the upper vermillion height. The measurements' mean biases were within 2 mm, but the 95% limit of agreement was more than 2 mm. Intra- and inter-observer measurements generally showed good reproducibility. Four inter-observer measurements, the upper and lower face heights, nose width, and pronasale to left alar base were clinically significant.
CONCLUSIONS: Measurements obtained from this 3D imaging system are valid and reproducible for evaluating CLP patients. CLINICAL RELEVANCE: The system is suitable to be used in a clinical setting for cleft patients. However, training of the operator is strictly advisable.

Entities:  

Keywords:  Accuracy; Cleft lip and palate; Oral and maxillofacial surgery; Orthodontics; Reproducibility; Three-dimensional analysis

Year:  2019        PMID: 31754872     DOI: 10.1007/s00784-019-03150-1

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  5 in total

1.  Three-dimensional facial scanner in the hands of patients: validation of a novel application on iPad/iPhone for three-dimensional imaging.

Authors:  Yuming Chong; Xinyu Liu; Mai Shi; Jiuzuo Huang; Nanze Yu; Xiao Long
Journal:  Ann Transl Med       Date:  2021-07

2.  Microtia Ear Reconstruction with Patient-Specific 3D Models-A Segmentation Protocol.

Authors:  Juan Pablo Rodríguez-Arias; Alessandro Gutiérrez Venturini; Marta María Pampín Martínez; Elena Gómez García; Jesús Manuel Muñoz Caro; Maria San Basilio; Mercedes Martín Pérez; José Luis Cebrián Carretero
Journal:  J Clin Med       Date:  2022-06-22       Impact factor: 4.964

3.  Reply to letter to the editor: "The iPad/iPhone 3D photography app-a promising device, but how about its accuracy?".

Authors:  Yuming Chong; Xinyu Liu; Mai Shi; Jiuzuo Huang; Nanze Yu; Xiao Long
Journal:  Ann Transl Med       Date:  2022-06

Review 4.  Validation of Vectra 3D Imaging Systems: A Review.

Authors:  Alberto De Stefani; Martina Barone; Sam Hatami Alamdari; Arjola Barjami; Ugo Baciliero; Federico Apolloni; Antonio Gracco; Giovanni Bruno
Journal:  Int J Environ Res Public Health       Date:  2022-07-20       Impact factor: 4.614

5.  Mini-microform cleft lip with complete cleft alveolus and palate: A case report.

Authors:  Kumiko Fujiwara; Mitsuna Yoshida; Naomi Nakamichi; Satoru Saitoh; Mayu Takaichi; Risa Ishizaka; Kei Tomihara; Makoto Noguchi
Journal:  Congenit Anom (Kyoto)       Date:  2021-04-04       Impact factor: 1.409

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.