Sara Boccalini1,2, Salim Si-Mohamed1,3, Maxime Matzuzzi4, Manon Tillier4, David C Rotzinger5, Didier Revel1,3, Loic Boussel1,3, Philippe Douek1,3. 1. Department of Cardiovascular and Thoracic Radiology, Hospices Civils de Lyon, Lyon, France. 2. Univerisity Claude Bernard Lyon 1, Lyon, France. 3. University Claude Bernard Lyon 1, CREATIS, CNRS UMR 5220, INSERM U1206, INSA-Lyon, France. 4. Faculty of Medicine Rockfeller, University Claude Bernard Lyon 1, Lyon, France. 5. Department of Radiology, University Hospital Center Vaudois, Lausanne, Switzerland.
Abstract
Background: Dual-energy dual-layer computed tomography (CT) scanners can provide useful tools, such as iodine maps and virtual monochromatic images (VMI), for the evaluation of myocardial perfusion defects. Data about the influence of acquisition protocols and normal values are still lacking. Methods: Clinically indicated coronary CT-angiographies performed between January-October 2018 in a single university hospital with dual-energy dual-layer CT (DE-DLCT) and different injection protocols were retrospectively evaluated. The two protocols were: 35 mL in patients <80 kg and 0.5 mL/kg in patients >80 kg at 2.5 mL/s (group A) or double contrast dose at 5 mL/s (group B). Patients with coronary stenosis >50% were excluded. Regions of interest were manually drawn on 16 myocardial segments and iodine concentration was measured in mg/mL. Signal-to-noise, contrast-to-noise ratios (CNR) and image noise were measured on conventional images and VMI. Results: A total of 30 patients were included for each protocol. With iodine concentrations of 1.38±0.41 mg/mL for protocol A and 2.07±0.73 mg/mL for protocol B, the two groups were significantly different (P<0.001). No significant iodine concentration differences were found between the 16 segments (P=0.47 and P=0.09 for group A and B respectively), between basal, mid and apical segments for group A and B (P=0.28 and P=0.12 for group A and B respectively) and between wall regions for group A (P=0.06 on normalised data). In group B, iodine concentration was significantly different between three wall regions [highest values for the lateral wall, median =2.03 (1.06) mg/mL]. Post-hoc analysis showed highest contrast-to-noise and signal-to-noise in VMI at 40 eV (P<0.05). Conclusions: Iodine concentration in left ventricular myocardium of patients without significant coronary artery stenosis varied depending on the injection protocol and appeared more heterogeneous in different wall regions at faster injection rate and greater iodine load. Signal-to-noise and contrast-to-noise gradually improved when decreasing VMI energy, although at the expenses of higher noise, demonstrating the potential of DE-DLCT to enhance objective image quality. 2022 Quantitative Imaging in Medicine and Surgery. All rights reserved.
Background: Dual-energy dual-layer computed tomography (CT) scanners can provide useful tools, such as iodine maps and virtual monochromatic images (VMI), for the evaluation of myocardial perfusion defects. Data about the influence of acquisition protocols and normal values are still lacking. Methods: Clinically indicated coronary CT-angiographies performed between January-October 2018 in a single university hospital with dual-energy dual-layer CT (DE-DLCT) and different injection protocols were retrospectively evaluated. The two protocols were: 35 mL in patients <80 kg and 0.5 mL/kg in patients >80 kg at 2.5 mL/s (group A) or double contrast dose at 5 mL/s (group B). Patients with coronary stenosis >50% were excluded. Regions of interest were manually drawn on 16 myocardial segments and iodine concentration was measured in mg/mL. Signal-to-noise, contrast-to-noise ratios (CNR) and image noise were measured on conventional images and VMI. Results: A total of 30 patients were included for each protocol. With iodine concentrations of 1.38±0.41 mg/mL for protocol A and 2.07±0.73 mg/mL for protocol B, the two groups were significantly different (P<0.001). No significant iodine concentration differences were found between the 16 segments (P=0.47 and P=0.09 for group A and B respectively), between basal, mid and apical segments for group A and B (P=0.28 and P=0.12 for group A and B respectively) and between wall regions for group A (P=0.06 on normalised data). In group B, iodine concentration was significantly different between three wall regions [highest values for the lateral wall, median =2.03 (1.06) mg/mL]. Post-hoc analysis showed highest contrast-to-noise and signal-to-noise in VMI at 40 eV (P<0.05). Conclusions: Iodine concentration in left ventricular myocardium of patients without significant coronary artery stenosis varied depending on the injection protocol and appeared more heterogeneous in different wall regions at faster injection rate and greater iodine load. Signal-to-noise and contrast-to-noise gradually improved when decreasing VMI energy, although at the expenses of higher noise, demonstrating the potential of DE-DLCT to enhance objective image quality. 2022 Quantitative Imaging in Medicine and Surgery. All rights reserved.
Authors: Thorsten Sellerer; Peter B Noël; Manuel Patino; Anushri Parakh; Sebastian Ehn; Sascha Zeiter; Jasmin A Holz; Johannes Hammel; Alexander A Fingerle; Franz Pfeiffer; David Maintz; Ernst J Rummeny; Daniela Muenzel; Dushyant V Sahani Journal: Eur Radiol Date: 2018-02-05 Impact factor: 5.315
Authors: Gastón A Rodríguez-Granillo; Miguel A Rosales; Elina Degrossi; Alfredo E Rodriguez Journal: Int J Cardiovasc Imaging Date: 2009-11-12 Impact factor: 2.357
Authors: Pim A L Tonino; William F Fearon; Bernard De Bruyne; Keith G Oldroyd; Massoud A Leesar; Peter N Ver Lee; Philip A Maccarthy; Marcel Van't Veer; Nico H J Pijls Journal: J Am Coll Cardiol Date: 2010-06-22 Impact factor: 24.094
Authors: Carlos Delgado Sánchez-Gracián; Roque Oca Pernas; Carmen Trinidad López; Eloísa Santos Armentia; Antonio Vaamonde Liste; María Vázquez Caamaño; Gonzalo Tardáguila de la Fuente Journal: Eur Radiol Date: 2015-12-23 Impact factor: 5.315
Authors: Robbert W van Hamersvelt; Martin J Willemink; Pim A de Jong; Julien Milles; Alain Vlassenbroek; Arnold M R Schilham; Tim Leiner Journal: Eur Radiol Date: 2017-01-25 Impact factor: 5.315
Authors: David C Rotzinger; Salim A Si-Mohamed; Jérôme Yerly; Sara Boccalini; Fabio Becce; Loïc Boussel; Reto A Meuli; Salah D Qanadli; Philippe C Douek Journal: Eur Radiol Date: 2021-03-19 Impact factor: 5.315