Literature DB >> 35782242

Effect of contrast material injection protocol on first-pass myocardial perfusion assessed by dual-energy dual-layer computed tomography.

Sara Boccalini1,2, Salim Si-Mohamed1,3, Maxime Matzuzzi4, Manon Tillier4, David C Rotzinger5, Didier Revel1,3, Loic Boussel1,3, Philippe Douek1,3.   

Abstract

Background: Dual-energy dual-layer computed tomography (CT) scanners can provide useful tools, such as iodine maps and virtual monochromatic images (VMI), for the evaluation of myocardial perfusion defects. Data about the influence of acquisition protocols and normal values are still lacking.
Methods: Clinically indicated coronary CT-angiographies performed between January-October 2018 in a single university hospital with dual-energy dual-layer CT (DE-DLCT) and different injection protocols were retrospectively evaluated. The two protocols were: 35 mL in patients <80 kg and 0.5 mL/kg in patients >80 kg at 2.5 mL/s (group A) or double contrast dose at 5 mL/s (group B). Patients with coronary stenosis >50% were excluded. Regions of interest were manually drawn on 16 myocardial segments and iodine concentration was measured in mg/mL. Signal-to-noise, contrast-to-noise ratios (CNR) and image noise were measured on conventional images and VMI.
Results: A total of 30 patients were included for each protocol. With iodine concentrations of 1.38±0.41 mg/mL for protocol A and 2.07±0.73 mg/mL for protocol B, the two groups were significantly different (P<0.001). No significant iodine concentration differences were found between the 16 segments (P=0.47 and P=0.09 for group A and B respectively), between basal, mid and apical segments for group A and B (P=0.28 and P=0.12 for group A and B respectively) and between wall regions for group A (P=0.06 on normalised data). In group B, iodine concentration was significantly different between three wall regions [highest values for the lateral wall, median =2.03 (1.06) mg/mL]. Post-hoc analysis showed highest contrast-to-noise and signal-to-noise in VMI at 40 eV (P<0.05). Conclusions: Iodine concentration in left ventricular myocardium of patients without significant coronary artery stenosis varied depending on the injection protocol and appeared more heterogeneous in different wall regions at faster injection rate and greater iodine load. Signal-to-noise and contrast-to-noise gradually improved when decreasing VMI energy, although at the expenses of higher noise, demonstrating the potential of DE-DLCT to enhance objective image quality. 2022 Quantitative Imaging in Medicine and Surgery. All rights reserved.

Entities:  

Keywords:  Computed tomography angiography (CT angiography); dual-energy computed tomography (DECT); image enhancement; iodine determination; myocardial perfusion imaging

Year:  2022        PMID: 35782242      PMCID: PMC9246727          DOI: 10.21037/qims-21-809

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  29 in total

1.  Dual-energy CT: a phantom comparison of different platforms for abdominal imaging.

Authors:  Thorsten Sellerer; Peter B Noël; Manuel Patino; Anushri Parakh; Sebastian Ehn; Sascha Zeiter; Jasmin A Holz; Johannes Hammel; Alexander A Fingerle; Franz Pfeiffer; David Maintz; Ernst J Rummeny; Daniela Muenzel; Dushyant V Sahani
Journal:  Eur Radiol       Date:  2018-02-05       Impact factor: 5.315

2.  Signal density of left ventricular myocardial segments and impact of beam hardening artifact: implications for myocardial perfusion assessment by multidetector CT coronary angiography.

Authors:  Gastón A Rodríguez-Granillo; Miguel A Rosales; Elina Degrossi; Alfredo E Rodriguez
Journal:  Int J Cardiovasc Imaging       Date:  2009-11-12       Impact factor: 2.357

3.  Angiographic versus functional severity of coronary artery stenoses in the FAME study fractional flow reserve versus angiography in multivessel evaluation.

Authors:  Pim A L Tonino; William F Fearon; Bernard De Bruyne; Keith G Oldroyd; Massoud A Leesar; Peter N Ver Lee; Philip A Maccarthy; Marcel Van't Veer; Nico H J Pijls
Journal:  J Am Coll Cardiol       Date:  2010-06-22       Impact factor: 24.094

4.  Quantitative myocardial perfusion with stress dual-energy CT: iodine concentration differences between normal and ischemic or necrotic myocardium. Initial experience.

Authors:  Carlos Delgado Sánchez-Gracián; Roque Oca Pernas; Carmen Trinidad López; Eloísa Santos Armentia; Antonio Vaamonde Liste; María Vázquez Caamaño; Gonzalo Tardáguila de la Fuente
Journal:  Eur Radiol       Date:  2015-12-23       Impact factor: 5.315

5.  Incremental value of dual-energy CT to coronary CT angiography for the detection of significant coronary stenosis: comparison with quantitative coronary angiography and single photon emission computed tomography.

Authors:  Rui Wang; Wei Yu; Yongmei Wang; Yi He; Lin Yang; Tao Bi; Jian Jiao; Qian Wang; Liquan Chi; Yang Yu; Zhaoqi Zhang
Journal:  Int J Cardiovasc Imaging       Date:  2011-05-06       Impact factor: 2.357

6.  How accurate and precise are CT based measurements of iodine concentration? A comparison of the minimum detectable concentration difference among single source and dual source dual energy CT in a phantom study.

Authors:  André Euler; Justin Solomon; Maciej A Mazurowski; Ehsan Samei; Rendon C Nelson
Journal:  Eur Radiol       Date:  2018-10-01       Impact factor: 5.315

Review 7.  Dual-energy CT and its potential use for quantitative myocardial CT perfusion.

Authors:  Aaron So; Jiang Hsieh; Suresh Narayanan; Jean-Baptiste Thibault; Yasuhiro Imai; Sandeep Dutta; Jonathon Leipsic; James Min; Troy LaBounty; Ting-Yim Lee
Journal:  J Cardiovasc Comput Tomogr       Date:  2012-08-24

8.  Feasibility and accuracy of dual-layer spectral detector computed tomography for quantification of gadolinium: a phantom study.

Authors:  Robbert W van Hamersvelt; Martin J Willemink; Pim A de Jong; Julien Milles; Alain Vlassenbroek; Arnold M R Schilham; Tim Leiner
Journal:  Eur Radiol       Date:  2017-01-25       Impact factor: 5.315

9.  Reduced-iodine-dose dual-energy coronary CT angiography: qualitative and quantitative comparison between virtual monochromatic and polychromatic CT images.

Authors:  David C Rotzinger; Salim A Si-Mohamed; Jérôme Yerly; Sara Boccalini; Fabio Becce; Loïc Boussel; Reto A Meuli; Salah D Qanadli; Philippe C Douek
Journal:  Eur Radiol       Date:  2021-03-19       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.