| Literature DB >> 35755908 |
Paulo Henrique Godoy1, Ana Paula Cassetta Dos Santos Nucera1, Andressa de Paiva Colcher1, Jéssica Escorcio de Andrade1, Davi da Silveira Barroso Alves2.
Abstract
Objectives: Obstructive sleep apnea (OSA) affects approximately one third of the population and can reach 90% prevalence in the elderly. There are screening tools to track the disease, however, their performance may differ according to population characteristics. This study aims to determine sensitivity, specificity, predictive value, likelihood ratio, and accuracy of the Berlin (BQ) and STOP-Bang (S-Bang) questionnaires and the Epworth sleepiness scale (ESS), comparing their performances, using polysomnography (PSG) as a gold standard, in a sample of elderly. Material andEntities:
Keywords: Aged; Mass Screening; Obstructive; Sleep Apnea; Surveys and Questionnaires
Year: 2022 PMID: 35755908 PMCID: PMC9210560 DOI: 10.5935/1984-0063.20220033
Source DB: PubMed Journal: Sleep Sci ISSN: 1984-0063
Characteristics of the patients with and without obstructive sleep apnea, diagnosed according to polysomnography, including the analyzed screening tools.
| Variables | Sample (n=62) | With OSA (n=45) | Without OSA (n=17) | |
|---|---|---|---|---|
| 73.0±8.4 | 73.0±8.4 | 74.7±8.1 | 0.49 | |
| >11 | 9 | >2 | 0.71 | |
| Woman | 51 | 36 | 15 | |
| >28.40±6.4 | 29.2±6.6 | >26.20±5.7 |
| |
| >51 | 39 | >12 | 0.15 | |
| Absence | 11 | 5 | 5 | |
| >21 | 16 | >5 | 0.65 | |
| Absence | 41 | 29 | 12 | |
| >32 | 23 | >9 | 0.90 | |
| Absence | 30 | 22 | 8 | |
| >17 | 10 | >7 | 0.20 | |
| Absence | 45 | 35 | 10 | |
| >6 | 4 | >2 | 0.66 | |
| Absence | 56 | 41 | 15 | |
| >13 | 8 | >5 | 0.32 | |
| Absence | 49 | 37 | 12 | |
| >34 | 29 | >5 |
| |
| Negative | 28 | 16 | 12 | |
| >42 | 32 | >10 | 0.35 | |
| Negative | 20 | 13 | 7 | |
| >22 | 17 | >5 | 0.54 | |
| Negative | 40 | 28 | 12 |
Univariate modeling of screening tools for association with obstructive sleep apnea and odds ratio.
| Tools | OR (95%CI) | |
|---|---|---|
| BQ | 0.02 | 4.35 (1.30-14.57) |
| S-Bang | 0.36 | 1.72 (0.54-5.50) |
| ESS | 0.54 | 1.46 (0.44-4.86) |
Analysis of screening tools for OSA according to sensitivity, specificity, positive and negative predictive value, positive and negative likelihood ratio, and accuracy, in the sample.
| Measures | BQ | S-Bang | ESS |
|---|---|---|---|
| SEN | 0.64 (0.49-0.78) | 0.71 (0.56-0.84) | 0.38 (0.24-0.53) |
| SPEC | 0.71 (0.44-0.90) | 0.41 (0.18-0.67) | 0.71 (0.44-0.90) |
| PPV | 0.85 (0.69-0.95) | 0.76 (0.61-0.88) | 0.77 (0.55-0.92) |
| NPV | 0.43 (0.24-0.63) | 0.35 (0.15-0.59) | 0.30 (0.17-0.47) |
| LR+ | 2.19 (1.02-4.72) | 1.21 (0.78-1.88) | 1.28 (0.56-2.94) |
| LR- | 0.50 (0.31-0.83) | 0.70 (0.34-1.46) | 0.88 (0.60-1.29) |
| ACC | 0.66 (0.53-0.78) | 0.62 (0.49-0.74) | 0.47 (0.34-0.60) |