Cardiovascular defects, injuries, and degenerative diseases often require surgical intervention and the use of implantable replacement material and conduits. Traditional vascular grafts made of synthetic polymers, animal and cadaveric tissues, or autologous vasculature have been utilized for almost a century with well-characterized outcomes, leaving areas of unmet need for the patients in terms of durability and long-term patency, susceptibility to infection, immunogenicity associated with the risk of rejection, and inflammation and mechanical failure. Research to address these limitations is exploring avenues as diverse as gene therapy, cell therapy, cell reprogramming, and bioengineering of human tissue and replacement organs. Tissue-engineered vascular conduits, either with viable autologous cells or decellularized, are the forefront of technology in cardiovascular reconstruction and offer many benefits over traditional graft materials, particularly in the potential for the implanted material to be adopted and remodeled into host tissue and thus offer safer, more durable performance. This review discusses the key advances and future directions in the field of surgical vascular repair, replacement, and reconstruction, with a focus on the challenges and expected benefits of bioengineering human tissues and blood vessels.
Cardiovascular defects, injuries, and degenerative diseases often require surgical intervention and the use of implantable replacement material and conduits. Traditional vascular grafts made of synthetic polymers, animal and cadaveric tissues, or autologous vasculature have been utilized for almost a century with well-characterized outcomes, leaving areas of unmet need for the patients in terms of durability and long-term patency, susceptibility to infection, immunogenicity associated with the risk of rejection, and inflammation and mechanical failure. Research to address these limitations is exploring avenues as diverse as gene therapy, cell therapy, cell reprogramming, and bioengineering of human tissue and replacement organs. Tissue-engineered vascular conduits, either with viable autologous cells or decellularized, are the forefront of technology in cardiovascular reconstruction and offer many benefits over traditional graft materials, particularly in the potential for the implanted material to be adopted and remodeled into host tissue and thus offer safer, more durable performance. This review discusses the key advances and future directions in the field of surgical vascular repair, replacement, and reconstruction, with a focus on the challenges and expected benefits of bioengineering human tissues and blood vessels.
Regenerative medicine and bioengineering of functional human tissues strive to fulfill the evergrowing need for organ repair, regeneration, or replacement. In the quest for performance and durability comparable to autologous tissues with no or minimal immune response, manufacturing challenges are only commensurate with the immense benefit for patients in a variety of conditions such as traumatic injuries, chronic and degenerative conditions, cancer, and autoimmune diseases. Tissue engineering, already impactful in areas such as dermatology with the manufacturing of cellular or acellular skin substitutes, has been making considerable strides in the vascular field. The development of human tissue material for vascular repair, replacement, or reconstruction aims to offer a readily available, off-the-shelf alternative to autologous conduits with characteristics similar in terms of immunogenicity and long-term functionality, while eliminating the wound care and operating time burden associated with harvesting patients’ own vessels.[1,2] The number of patients requiring replacement vascular conduits is steadily growing. Cardiovascular disease is the leading cause of mortality in the United States, and in 2018 alone, 26.1 million adults had coronary heart disease, heart failure, or stroke. Often the outcome of these conditions requires surgery, and every year, ≈370 000 coronary artery bypass grafts (CABG), 156 000 heart valve operations, and 86 000 coronary endarterectomies are performed in the United States alone.[3] Peripheral artery disease (PAD) and vascular injuries, including civilian and military traumatic injuries, represent another area of critical need for replacement vessels. In 2015, >200 million people globally were living with PAD[3,4] with a 13% increase in prevalence in high-income countries between 2000 and 2010,[3,4] while vascular injuries especially in the military setting are on the rise.[5,6]Furthermore, patients on hemodialysis for end-stage renal disease (ESRD) require access to the circulatory system multiple times per week relying on either a central catheter or a superficial arteriovenous loop access created surgically. The arteriovenous conduit is most often on the upper limb, either with the patients’ vessels (arteriovenous fistula [AVF]) or by the insertion of a synthetic graft such as expanded polytetrafluoroethylene (ePTFE). The incidence of ESRD has been steadily increasing since 1980,[7] with 809 000 prevalent cases in the United States as of December 2019, of which 62.5% were treated with hemodialysis.[8] Although autologous AVF is the preferred option in most cases,[9] as of 2019, only 15.2% of patients initiate hemodialysis with an AVF, leaving the vast majority to rely on central venous catheters or synthetic grafts, which puts them at high risk for infection and thrombosis and highlights the need for new materials.[9]Vascular replacements have been used for over 60 years, initially with synthetic polymers followed by the first autologous saphenous vein (SV) graft implemented in 1967 by Favaloro et al.[10] Today, vascular grafts originate from 4 broad sources: synthetic polymers, xenogeneic tissues, allogeneic or autologous tissues, and engineered tissues. While all have proven functional to a degree, each of these types of vascular replacements has vastly different outcomes in vivo, with infection, inflammation, occlusion, and degradation presenting as the most frequent failure modes.[11] One of the greatest challenges to deployment of vascular grafts is their adoption by the host and ability to remodel into new tissues. Regenerative medicine focuses on the production of materials or techniques that harness the body’s own remodeling abilities, to improve these outcomes, and offer recipients the experience of fully functional organs. This review details the challenges of bioengineering human blood vessels and their expected applications, comparing their features with those of historical conduits and with the current options in development to outline potential future avenues of research.
Traditional Vascular Grafts
Traditional vascular grafts in use today include synthetic conduits, xenografts of mostly bovine or porcine origin, cadaveric allografts, and autografts obtained by harvesting a patient’s own vessels, primarily SVs or internal mammary arteries (IMAs).
Nondegradable Polymer Grafts
Synthetic nondegradable polymer vascular grafts are made of ePTFE (Gore-Tex), polyethylene terephthalate (Dacron), and polyurethane (PU); their appeal lies in their relatively inexpensive production, off-the-shelf availability, and long shelf lives.In practice, ePTFE grafts have been classified as low porosity (<30 μm internodal distance) and high porosity (>45 μm internodal distance), with the observation that higher porosity would offer greater potential for tissue ingrowth while lower porosity means stiffer, less flexible grafts with reduced tissue ingrowth and endothelialization.[12,13] Drawbacks, in small-diameter (<6 mm) settings in particular, include problematic long-term patency due to the graft’s susceptibility to thrombosis, inflammation, stenosis, and associated compliance mismatch with the host vessels.[14] On par with infection, thrombosis is the other major complication of ePTFE vascular grafts, particularly at smaller diameters.[12,13,15]Dacron offers another type of synthetic nondegradable polymer conduit. Textile vascular grafts made from polyethylene terephthalate fibers are either woven or knitted. While woven grafts have small pores with lower permeability and less bleeding, knitted grafts formed by looping fibers together have larger pores that promote greater tissue ingrowth and are more compliant. However, due to larger pore sizes, knitted grafts must be preclotted with a degradable coating of albumin, gelatin, or even blood to prevent plasma seepage and seroma formation after implantation, especially in high-pressure vessels like the aorta.[16] Poor patency over the long-term, notably in small-diameter vessels, still limits Dacron use clinically.[17] Systematic evaluation and meta-analysis of randomized controlled trials comparing Dacron and ePTFE have shown no substantial advantages of one conduit type over the other in terms of primary and secondary patency rates or infection.[18]PU vascular grafts represent the other segment of synthetic grafts, constructed as copolymers of 3 different monomers: (1) hard, crystalline segments for rigidity; (2) a polymer chain extender; and (3) soft, amorphous segments for flexibility, most commonly polyester, polyether, or polycarbonate.[19] Degradation of traditional PU grafts under physiological conditions is a concern, with structural failure linked to enzymatic attack, oxidative stress, and reaction to strain or stress cracking, but the main concern in clinical applications is the risk of thrombosis.[19] Overall, ePTFE, Dacron, and PU grafts show little or no transmural tissue ingrowth and similar patency rates over time.[11]Nondegradable synthetic grafts pose continued risk to patients in terms of patency rates, mechanical compliance, infection, and durability,[15] as shown in ePTFE explant (Figure 1). Up to 90% of patients with graft thrombosis have intimal hyperplasia that led to stenosis,[20] and infection is reported in up to 17% of synthetic arteriovenous grafts that are used for hemodialysis access.[21] More critically, patency rates of grafts at diameters <5 mm are unacceptably low.[11]
Figure 1.
Explants of expanded polytetrafluoroethylene grafts used as hemodialysis vascular access at 7 mo post-implantation. A, Thrombosis (arrowhead), inflammatory exudate (IE), adventitia (Ad), graft (G) and pannus (P) in trichrome staining. B, Fragmented wall with Ad and fibrosis in the defect (F) and thrombosis (T) in hematoxylin and eosin staining. C, Multinucleated giant cells (large arrows), macrophages (small arrow), and neutrophils (arrowhead) in hematoxylin and eosin staining. D, Gram-positive cocci (arrows) within intraluminal fibrin along luminal surface in Gram staining.
Explants of expanded polytetrafluoroethylene grafts used as hemodialysis vascular access at 7 mo post-implantation. A, Thrombosis (arrowhead), inflammatory exudate (IE), adventitia (Ad), graft (G) and pannus (P) in trichrome staining. B, Fragmented wall with Ad and fibrosis in the defect (F) and thrombosis (T) in hematoxylin and eosin staining. C, Multinucleated giant cells (large arrows), macrophages (small arrow), and neutrophils (arrowhead) in hematoxylin and eosin staining. D, Gram-positive cocci (arrows) within intraluminal fibrin along luminal surface in Gram staining.Several research strategies have been implemented with the goals of reducing infection rates, promoting endothelialization, and inhibiting inflammation. Thus far, these have failed to produce significant benefits.[11] Coatings may contain heparin, create nitric oxide, utilize micro-RNAs to decrease intimal hyperplasia,[22] or stimulate endothelial cell (EC) growth through factors such as VEGF-R2 (VEGF [vascular endothelial growth factor] receptor 2),[13] angiogenic micro-RNAs,[23] or resorbable polymers to promote endothelialization.[24] These coatings have yielded unconvincing results thus far, likely because of the limited time during which these coatings are active due to passivation by contact with blood proteins, as well as host responses to the bulk foreign material of the conduit.[25] Finally, seeding with ECs has been explored over the past 20 years with limited clinical success.[14,19,25-28] In an effort to improve the hemocompatibility of ePTFE grafts, autologous ECs have been seeded onto the lumen.[26] ECs derived from small vein biopsies were expanded and cultured on ePTFE grafts over 4 weeks, which then were implanted as femoropopliteal grafts in patients with severe PAD. In a study of >300 patients who received the endothelialized grafts, a 76% 5-year patency rate was comparable to that of native SV, making this endothelialization approach a possible avenue for exploration.[26] However, the need for harvesting suitable numbers of autologous ECs from vein segments, the time and cost involved in the growth and seeding of these ECs, along with challenges with long-term EC adherence to artificial surfaces, have prevented more widespread adoption of this technology.
Autologous Blood Vessels
Of all graft options, autologous blood vessels possess physiological properties that align the most closely with that of the vasculature requiring repair (Figure 2), thus making them an appealing first option. Options frequently used in cardiovascular surgery range from small-diameter arteries (radial artery and internal thoracic artery) to greater and lesser saphenous, brachial, or other arm veins.[29] In coronary artery bypass surgery, the most recent American College of Cardiology guidelines recommend the use of the autologous arteries over SVs, specifically the left internal mammary (also known as thoracic) artery followed by its right counterpart or both IMA in a procedure called bilateral IMA grafting, and the radial artery for multivessel CABG, all of which show better patency outcomes over the use of SV grafting.[30] In coronary revascularization surgery, 3% to 12% of SV grafts become occluded within the first month following CABG.[31,32] Long-term patency of the SVs in this setting is poor, with up to 50% of grafts failing within 10 years, mostly due to fast-progressing atherosclerosis on a foundation of neointimal hyperplasia.[31,32]
Figure 2.
Strengths and weaknesses of different vascular graft materials. A semiquantitative heat map representing the qualities of the vascular graft materials discussed, with green indicating high, yellow indicating medium, and red indicating low relative amounts or incidence of the parameters listed on the vertical axis. TEVG indicates tissue-engineered vascular graft. Illustration credit: Patrick Lane.
Strengths and weaknesses of different vascular graft materials. A semiquantitative heat map representing the qualities of the vascular graft materials discussed, with green indicating high, yellow indicating medium, and red indicating low relative amounts or incidence of the parameters listed on the vertical axis. TEVG indicates tissue-engineered vascular graft. Illustration credit: Patrick Lane.The superior performance of the IMA may be explained by its anatomic structure. It is an elastic artery with elastin unevenly distributed in its structure: while the origin, proximal, and middle parts of the IMA contain 5 to 10 elastin laminae, the distal segment has a predominately muscular tunica media containing a limited number of elastic lamellae[33]; when used as a vascular graft, the presence of distensible elastin in the media correlates with considerably less intimal thickening as compared with other muscular arteries.[33] IMA grafts placed in the aorta-coronary circulation are inherently accustomed to the high-pressure arterial flow, and the size similarity between the grafts and the coronary arteries may play a role in protecting the IMA from development of atherosclerosis and may contribute to long-term patency.[34,35]The ECs of the IMA are densely stacked and firmly anchored to the subendothelium and encounter minimal disturbance during IMA harvesting. The IMA endothelium displays fewer fenestrations and lower intercellular junctional permeability as compared with the endothelium of SV, which might prevent lipoproteins from entering the subendothelial space and instigating inflammation and intimal hyperplasia. The ECs of the IMA are also rich in heparin sulfate and eNOS (endothelial NO synthase), which may help with maintaining patency after CABG.[35]Early IMA graft failure is most commonly attributed to technical errors with harvesting and graft anastomosis. When thickening of the intima happens, it consists primarily of smooth muscle cells (SMCs), proteoglycan, collagen, and elastin fibers with luminal ECs and is generally observed at the anastomotic suture site between 1 week to 2 months.[35] Studies suggest that intimal thickening does not increase with time.[35]In patients experiencing PAD and requiring surgical revascularization, the use of autologous SV is recommended over synthetic materials (ePTFE; Dacron) due to better patency rates and reduced risk of reintervention.[36] Multiple studies and meta-analyses have demonstrated superiority of SV grafts in femoropopliteal bypass, particularly at longer points of follow-up to synthetic and xenogeneic alternatives.[37,38]The SV structure is that of a typical vein, with intimal, medial, and adventitial layers. The intima is lined by an endothelium that lies on a fenestrated basement membrane. This endothelium may be more susceptible than that of the IMA to injury during vessel harvesting, storage, and implantation because it is less firmly anchored to the subendothelium.[39] The thin media is composed of SMCs arranged in ≥2 circular layers and interlaced between bundles of collagen and elastic fibers and separated from the intima by a small internal elastic membrane. A relatively thick adventitia shows a loose network of longitudinally oriented collagen bundles and embedded vasa vasorum.[40]A vein inserted into the arterial circulation develops intimal hyperplasia.[41] Increased wall tension becomes the significant driver of development of intimal thickening after implantation into the arterial environment, and deformation of SMCs by pulsatile stretch stimulates their proliferation while deformation of the vessel wall in a circumferential direction is associated with medial thickening.[42-44] Dysfunctional endothelial regulation exacerbates the development of intimal hyperplasia, while EC loss induces platelet adhesion and accumulation of inflammatory cells in the denuded areas, which in turn stimulates the release of cytokines including PDGF-BB (platelet-derived growth factor BB), bFGF (basic FGF [fibroblast growth factor]), and IGF-1 (insulin-like growth factor 1). These signals stimulate SMC proliferation in the intima.[31] Attenuation of EC production of antimitotic agents including prostacyclin, NO, and adenosine further contributes to SMC migration and replication.[31] All these elements combine to allow activated SMCs to synthesize and release collagen and other ECM (extracellular matrix) proteins in the intima, leading to intimal hyperplasia.[31,45]After implantation into arterial environments, SV grafts rapidly remodel with a change in lumen size and wall thickness,[31,44] mostly within the first 30 days but then continuing thereafter, to gradually stabilize in response to hemodynamic stress.[46-48] In addition to intimal hyperplasia, atherosclerotic disease progresses rapidly in SV grafts explaining the disappointing long-term patency of SV grafts in CABG and in peripheral vascular surgery.[45,49]With the goal of limiting the damage inflicted to the endothelium of harvested veins, research efforts have focused on the protection of vessels harvested for use in revascularization surgery. DuraGraft is an example of a flushing and storage solution that is approved in Europe and was developed to protect the structural and functional integrity of the vascular endothelium. It is an ionically and pH-balanced physiological salt solution containing L-glutathione, L-ascorbic acid, L-arginine, and other additives, designed to minimize the risk of neointimal hyperplasia stemming from injury to the vein’s endothelium during harvesting and storage.[50] Haime et al compared the experimental solution to heparinized saline in patients undergoing CABG with SV (1036 versus 1400 patients, respectively). Long-term follow-up showed a potential benefit over heparinized saline with a 45% lower occurrence of nonfatal myocardial infarction after 1000 days and a significantly lower risk for revascularization and MACE but failed to show differences in the rate of events on the short term; mortality was comparable between groups.[50]
Allogeneic and Xenogeneic Materials
Cryopreserved Grafts
Cryopreserved cadaveric allogeneic veins (CVGs) have been used for >2 decades as an alternative when synthetic grafts are undesirable, such as in the case of an infected field and when autologous veins are unavailable. The need for cryopreservation and specialized storage and the related planning, thawing, and preparation time, all represent practical limitations to the use of such conduits. In addition, cryopreserved veins have accumulated insults inflicted during harvesting and storage that decrease the functional performance of the endothelium. Most importantly, the presence of viable allogeneic cells elicits an immune response from the recipient that not only jeopardizes patency but also impacts the future chance of successful organ transplant in the case of end-stage kidney disease.[51] Overall, patency and performance reported in the literature are mixed, across indications and use, due to a combination of these factors.[51-55] Multiple studies have investigated the use of CVGs as an alternative in surgical procedures including infrainguinal bypass, CABG, hemodialysis access, and portal vein reconstruction when autologous SV is unavailable.[51-55] Primary patency rates are poor in the majority of studies, with thrombotic occlusion as the primary cause of graft failure.[52,53,55] In a series of CVGs used for CABG, only 1 of 17 remained patent after 12 months.[55] In peripheral revascularization procedures, highly variable primary patency rates (17%–53%) at 1 year were reported in patients with infrainguinal bypass using CVG.[52,53] Long-term patency rates were 19% to 22% and 3% at 2 years and 4 years, respectively.[53] Again, occlusion resulting from thrombosis was the primary cause of CVG failure.[52,53] Carpenter et al[56] examined 19 explanted samples from a prospective study of 40 patients undergoing below-knee lower extremity revascularization. Of the explanted CVGs, 47% had moderate or severe intimal thickening and with a trend of intimal thickening increasing with time after implantation. A cellular infiltrate, which was evenly distributed throughout the intima, media, and adventitia, was detected in all explanted grafts with moderate or severe cellular infiltration in one-third of grafts. Leukocytes, T cells (CD3 [cluster of differentiation 3] and CD8), and HLA II-DR positive markers were identified that suggested that an adaptive immune response might be driving allograft failure.[56] However, low-dose immunosuppression therapy did not improve allograft patency significantly, and evidence for involvement of immunologic rejection in cryopreserved vein failure is variable and inconsistent in other studies.[57]
Xenogeneic Cardiovascular Grafts
ECM grafts of xenogeneic origin combine the benefits of abundant supply with a biological tissue that is strong, pliable, and durable (Figure 2). Cardiovascular xenografts are derived from varying mammalian tissue sources, often bovine or porcine. All vascular xenografts currently utilized are decellularized, with the intention of lowering the immunogenic potential of the graft. Xenograft efficacy and durability are heavily influenced by their specific application. Whether utilizing CorMatrix porcine small intestinal submucosa,[58,59] bovine carotid artery (Artegraft),[60-64] or mesenteric vein (ProCol)[65,66] for arteriovenous access for hemodialysis, some studies have shown adequate performance compared with autologous or synthetic alternatives. The overall lower pressures applied to arteriovenous grafts, as compared with arterial grafts, may underlie some of the performance benefits observed with xenografts in dialysis access.Beyond hemodialysis, xenografts have also been utilized for vascular repair with satisfactory patency and long-term performance,[67,68] even when compared with autologous grafts.[69,70] Not all vascular applications of xenograft ECM have shown desirable efficacy, however. While some successes have been documented,[71,72] implementation of xenografts to repair cardiac defects and damage have produced higher rates of reintervention and failure in both neonatal/pediatric populations,[73-75] as well as adults.[76,77] Utilization of xenografts to repair and reconstruct arteries has produced notable mechanical failures of the materials.[78-82] These adverse events suggest that not all cardiac and vascular sites, especially those that experience mechanical stress or high pressure, are equally suited for xenograft-based repairs. Serum samples collected from patients who received a decellularized allograft showed a slight increase in IgG levels in the first 4 months after implantation. But IgG responses to Matrix P valves were 6× higher than for allografts, indicating a sustained immune response against the xenograft and providing a potential basis for xenograft ECM degradation and graft failure.[82]A major appeal of utilizing biological materials for cardiovascular repair is the putative ability of the material to remodel and to be adopted as a functional tissue in the host. Although some studies have shown evidence of remodeling over time,[83-85] the responses observed to vascular xenografts may not accurately recapitulate the typical range of response to these ECM materials, as almost all instances of histological examination occur after the failure of an implanted graft. To obtain a better perspective of xenograft ECM remodeling over time, an explanted postmortem series of 10 CorMatrix xenografts from neonatal and pediatric patching of the great vessels or coronary arteries was reported.[86] In these samples, an intima formed around the ECM xenograft and progressively thickened over time (1 week to 26 months). The new tissue was lined by an endothelium within 1 week of implantation, and CD31+ capillaries formed on the luminal side of the patch. During the time course, the ECM xenografts degraded and remained acellular, suggesting that such materials were not remodeled per se but instead function as a scaffold for new tissue growth surrounding the original xenograft implant. In this way, xenogeneic tissues may mimic the remodeling of synthetic materials to a degree, with limited host cell infiltration into the implant, and formation of extensive host tissue surrounding the graft.[86]While some histological data demonstrate partial recellularization of xenografts, many clinical reports of explanted specimens provide evidence of inflammation, calcification, and neointima formation without cellularization of the implanted ECM. Failed CorMatrix grafts used as valve replacements in the aorta and pulmonary artery showed a foreign body giant cell response, no cell infiltration, and gradual degradation of the ECM.[71,72] An inflammatory response comprised of eosinophils, macrophages, and giant cell reactions has been repeatedly demonstrated in explants of CorMatrix and CardioCel.[76,80,87] In limited observation of a single patient with 2 CorMatrix patches, 1 patch generated a marked inflammatory response while the other did not, indicating that such responses could be tissue specific or related to the surgical procedure.[86] In many but not all cases, explanted xenografts showing inflammation also show fibrosis and calcification, processes that are undesirable for development of true functional neotissues.[80,87,88] In a study where 15% (9/60) CardioCel heart valve grafts from both adults and children failed, all explanted grafts showed matrix degeneration and a lack of recellularization.[89]In summary, xenografts for cardiovascular repair and reconstruction offer potential benefits and have been successfully deployed in some surgical applications. However, graft failures due to loss of graft integrity, inflammation, and fibrosis have repeatedly been observed, often in environments experiencing mechanical stress or high pressures. And despite evidence of recellularization in preclinical models, most observed xenograft explants from patients do not show recellularization of the graft itself and instead demonstrate repopulation of cells around the periphery of the graft. When such perigraft tissue growth is outpaced by degradation of the xenogeneic ECM, these grafts can fail.
Current and Future Research Avenues
Autologous grafts still remain the preferred option for vessel replacement or repair, eliminating the risk of rejection presented by xenografts and allogeneic vein grafts, offering a resistance to infection better than that of synthetic materials and displaying mechanical properties most closely aligned with the conduit to be replaced. However, they face limitations with regard to availability, risk of thrombosis due to damaged endothelium, intimal hyperplasia, and accelerated atherosclerosis.[29] New research avenues focus on the generation of innovative materials that would decrease the risk of infection, thrombosis, and rejection and either undergo remodeling by the host or induce regeneration and repair of the host own tissues (Figure 3).
Figure 3.
The future of tissue-engineered vascular grafts. Multiple avenues of research continue to advance the field of engineering of vascular grafts. Some of the approaches undertaken and discussed in this article are depicted herein. Illustration credit: Patrick Lane.
The future of tissue-engineered vascular grafts. Multiple avenues of research continue to advance the field of engineering of vascular grafts. Some of the approaches undertaken and discussed in this article are depicted herein. Illustration credit: Patrick Lane.
Gene Therapy
Gene therapy is being explored in a variety of diseases, from cancer to genetic, infectious, and degenerative diseases. Therapeutic genes are brought to the cells by vectors, including nonviral (plasmids, bacterial) and viral vectors. Alternatively, patients’ own cells can be harvested, genetically modified, and returned to the patients. More recently, CRISPR (clustered regularly interspaced short palindromic repeats) and other technologies and editing human genes directly to repair mutations that cause diseases represent a potential evolution of the technology.[90]In PAD, a Cochrane systematic review published in 2018 looked at 17 randomized and quasi-randomized studies that evaluated gene therapy versus no gene therapy (excluding cell-based therapies) in people with PAD, providing data for a total of 1988 participants.[91] Growth factor-encoding gene therapy was the most frequently studied with 6 studies using VEGF-encoding genes, 4 using HGF (hepatocyte growth factor)-encoding genes, and 3 using FGF-encoded genes. In addition, HIF-1L (hypoxia-inducible factor 1-alpha) gene therapy was evaluated in 2 studies and developmental endothelial locus-1 gene therapy and SDF-1 (stromal cell-derived factor-1) gene therapy in one study each (Figure 3). None of these gene therapy studies in PAD showed clear differences in the key outcomes of amputation-free survival, major amputation, and all-cause mortality between the two groups (gene therapy versus no gene therapy). Studies did not allow conclusions to be reached on impact of gene therapy on wound healing, quality of life, ankle-brachial index, symptom scores, or claudication distance.[91]In the cardiovascular area specifically, several products designed to trigger neoangiogenesis and address critical limb ischemia, intermittent claudication, or ischemic heart disease have been studied in clinical trials. In a 2013 review of gene therapy for the revascularization of the ischemic myocardium, Kaminsky et al[92] point out that a number of angiogenic mediators such as VEGF, FGF, HGF, and others encoded by DNA plasmids or adenovirus vectors have been extensively studied with disappointing results. Aside from angiogenic outcomes, other goals of gene therapy can include reduction of fibrosis, induction of replication of endogenous cardiomyocytes, or expansion of existing cardiac stem cells, though these outcomes have not yet been significantly demonstrated. Some of the issues faced by angiogenesis-based therapeutic approaches and gene therapy products lay in the identification of the most effective route of delivery, dosing, and frequency of treatment that are needed to achieve results. In addition, the field needs progress in decreasing immunogenicity of delivering vectors, identifying nonintegrative vectors for enhanced patient safety, minimally invasive delivery techniques for genetic delivery payloads, as well as gaining a better understanding of off-target effects of gene products or gene integration sites, are needed.Despite many years of exploration and relative lack of clinical benefits, there is a resurgence of interest in newer gene therapy approaches, led by cell reprogramming, though these efforts remain largely nascent and preclinical.[93]
Cellular Reprogramming
Postmyocardial infarction, for example, the most promising option seems to be the cellular reprogramming approach that aims at regenerating cardiomyocytes directly from endogenous scar fibroblasts, bypassing the typical cardiomyocyte progenitor state. In animal models, this approach to cardiac regeneration by injection of fibroblast reprogramming factors (Gata4, Mef2c, and Tbx5 [GMT])[94,95] shows 10% to 25% improvement from baseline in postinfarct ejection fraction and reduction in fibrosis by almost 50%.[96-100] Cardiac gene therapy that aims to reconstitute myocardium, as opposed to simply increasing angiogenesis, may help resolve some of the obstacles that myocardial cell therapy faces, including poor electromechanical integration and low implanted cell survival.[101]
Biodegradable Vascular Grafts
The concept of biodegradable vascular grafts was proposed as early as 1919.[102] Biodegradable vascular grafts comprise a synthetic 3-dimensional framework that aims to elicit cell adhesion, infiltration, and proliferation, thus allowing cells to produce their own ECM and finally transform into native tissue without residual polymers.[103] Multiple biodegradable polymers for vascular grafts have been investigated, including polyglycolic acid (PGA), polylactic acid, poly(ε-caprolactone), polydioxanone, poly(glycerol-sebacate), poly-4-hydroxybutyrate, and their copolymers and polymer combinations.[104] This field has struggled to achieve the appropriate balance between premature and late polymer scaffold degradation. Finding this balance is a critical consideration for the design of biodegradable scaffolds and remains a challenge for clinical application, since premature degradation leads to early loss of structural integrity and increased risks of rupture, while late degradation causes foreign body response and prevents adaptive neotissue formation. Many researchers have utilized biodegradable polymers as a scaffold for generating a vascular graft in vitro, in particular, in pediatric cardiac surgery indications to potentially repair congenital defects.[105-108]Xeltis AG developed a highly porous polymer-based degradable scaffold composed of chain-extending poly-caprolactone with 2-ureido-4[1H]-pyrimidinone (a bioabsorbable supramolecular polyester),[109] designed to be immediately functional while offering physiochemical characteristics thought to enable cell infiltration and subsequent endogenous tissue formation. Following encouraging functional results in animal models,[110] the graft was implanted in a feasibility trial in one center in Moscow in 5 pediatric patients (aged 4–12 years) as an extracardiac connection between the inferior vena cava (IVC) and the pulmonary artery. All patients were doing well at 24 months of follow-up, with no graft-related serious adverse events, and transthoracic echocardiography demonstrated adequate function of the conduit in all patients while magnetic resonance imaging showed anatomic and functional stability of the restorative grafts.[111] Early outcomes of a preliminary global, multicenter clinical study in 18 patients, using the material as an implantable replacement cardiac valve showed early failure of the implanted valves. The early mechanical valve failures led to structural modifications of the implant and highlighted the need for further evaluation of the material.[112]Incremental advances have somewhat improved the performance of nonbiodegradable synthetic grafts made of ePTFE, Dacron, or PU, which compared with degradable grafts are relatively inexpensive to produce and have long shelf lives but carry a significant risk of failure due to thrombosis, stenosis, and infection. The biodegradable polymer grafts have been developed with the goal of transforming in situ from a polymeric tube to a living, vessel-like structure, producing a broadly available therapy for patients without autologous alternatives. The immune response to synthetic scaffolds is poorly understood and requires further investigation (Figure 3).[113]Finding the proper pore size affects the remodeling outcomes. Pore size may be more critical for materials that degrade slowly or have poor cell adhesion. In general, smaller pores in the size range of 25 to 40 μm tend to promote macrophage infiltration better than larger pores.[114] Many synthetic grafts are electrospun—a process that typically yields small pores.From the perspective of mechanical properties, both currently available nondegradable and biodegradable synthetic grafts are stiffer than native arteries. The mechanical discordance at the anastomoses induces disruptions of transmural stress and shear stress at the intima level, negatively impacting both ECs and SMCs, resulting in turbulent flow and anastomotic or neointimal hyperplasia, ultimately leading to thrombosis. Although an attractive concept, potential pitfalls of surgically implanting synthetic biodegradable scaffolds include degradation times that are not aligned with the rate of remodeling in the host, leading to risk of aneurysms, early structural and mechanical failure, as well as the risk of chronic inflammatory responses and fibrosis with stenosis and thrombosis associated risks.To try and resolve some of these issues, many researchers have turned to biodegradable polymers as scaffolds for generating a vascular graft in vitro, and these approaches are discussed in depth in the next section.[115-117]
Tissue-Engineered Vascular Grafts
Development of the next generation of bioengineered vascular grafts should answer in practice the needs of both patients and the health care professionals and hospital setting by eliminating altogether the growth time, wound care, or operating time burden of harvesting autologous cells, veins, or arteries. Simple standard storage on-site, for example, is critical for emergent revascularization procedures and eliminates any preprocedure delay due to shipping, thawing rinsing, or coating. The mechanical and structural properties of the replacement vessels must allow for surgical handling and tolerate the arterial system high-pressure environment with low permeability and offer functional performance on par or superior to synthetic grafts and autologous vasculature in particular, with regard to risk of infection, thrombosis, or mechanical failure. To provide a meaningful alternative to autologous veins or arteries, the bioengineered replacement vessels must show minimal immunogenic potential to avoid triggering rejection of the implant and preserve patients’ future opportunities of organ transplant, therefore, eliminating the use of xenogeneic or allogeneic cellular material.[1]The first engineering approach to develop a biological vascular graft was the formation of patient-specific tissue tubes by Charles Sparks in the 1970s. These autologous tubes were formed by the foreign body response to a silicone mandril—called the Sparks mandril—that was implanted subcutaneously into the patient’s leg. The fibrous tissue surrounding the mandril, created by a foreign body response, could be later harvested as an autologous tubular graft. However, this approach was abandoned due to low patency rates and aneurysmal remodeling in preclinical and clinical trials.[118] The first tissue-engineered vascular graft (TEVG) produced in vitro with vascular cells was reported in a seminal study by Weinberg and Bell[119] in 1986. This structure was made of a collagen gel tube supported by a Dacron sleeve as a protective jacket. Although this first TEVG resembled a biological artery with its SMC-populated wall, EC lining in the lumen, and fibroblast-populated adventitia layer, its mechanical properties without the Dacron support did not allow for in vivo trials. Since these pioneering studies, vascular tissue engineering has improved remarkably by utilizing multidisciplinary approaches.The first TEVG transplantation in a human was performed by Shin’oka et al[120] in 1999. The patient was a 4-year-old girl who had undergone pulmonary artery angioplasty and the Fontan procedure due to a single right ventricle and pulmonary atresia at the age of 3 years. Complete blockage of the pulmonary artery was detected 7 months after the Fontan procedure. Shin’oka et al reconstructed the blocked pulmonary artery with a tubular scaffold made of a poly(L-lactide-co-e-caprolactone) sponge reinforced with PGA fiber seeded with the patient’s own cells (Figure 4A). Approximately 3 months before the surgery, a 2-cm segment of peripheral vein of the patient was harvested, and the cells from the vessel wall were expanded in vitro. Ten days before transplantation, the tubular polymeric structure (2 cm length, 1 cm diameter, 1 mm wall thickness) was seeded with the autologous expanded cells to form the TEVG. This method of seeding the scaffolds was improved for subsequent patients, by using either autologous bone marrow cells or mononuclear bone marrow cells to seed the graft on the day of implantation.[121]
Contribution of Computer Modeling, Personalized Medicine, and Systems Biology Approaches
The purpose of personalized medicine and its identification of patient-specific profiles incorporating genetic and genomic data to clinical factors and environmental risks is to offer disease prevention and treatment strategies tailored to the individuals. Its application to the area of vascular grafts has explored many different diseases or conditions. Applying precision medicine and next-generation sequencing to the study of aortic aneurysms, for example, showed that despite common manifestations, genetic factors play a critical role in the risk of aortic root and ascending thoracic aortic aneurysms, as opposed to abdominal aortic aneurysms, which are primarily driven by atherosclerosis, and allowing for the identification of target pathways for potential new therapeutic approaches in these patients.[158] In cardiac transplant recipients, gene expression profiling of peripheral blood cells is being evaluated to detect the risk of rejection and help in the management of immunosuppressive agents, as an alternative to repeated endomyocardial surveillance biopsies, and could possibly be applied to allogeneic and xenogeneic vascular grafts to monitor the immune response.[159]Computational modeling and systems biology approaches applied to the study of vascular pathophysiology have produced several examples of multiscale models, such as for atherosclerosis, in-stent restenosis, remodeling of a vascular tissue-engineered scaffold, or venous graft remodeling. By creating these in-silico models, this approach would guide the development of new materials and devices and help avoid the limitations of current grafts. Including genomics in these complex models is anticipated to contribute to refining personalized medicine in these areas.[160]
Conclusions and Predicted Clinical Applications of Emerging Technologies
Vascular grafts offer immense potential to meet the ever-increasing needs of patients in nearly all fields of cardiovascular surgery, including hemodialysis access for end-stage renal disease, cardiovascular bypass, limb rescue in vascular trauma, and reconstruction and repair of congenital heart defects for pediatric patients who would benefit greatly from a graft that would grow as the patient matures. For most of these applications, autologous vascular grafts have been the standard of care for decades, but their limited supply and the side effects of excision of native arteries or veins are significant (Figure 2). Patients with end-stage renal disease on hemodialysis can benefit greatly from AVF as vascular accesses, but the time to maturation and failure of maturation in many patients result in other vascular access placements. In controlled trials, xenogeneic vascular grafts often have patency superior to synthetic conduits, but notable frequency of failure, particularly in environments experiencing mechanical stress, inflammatory responses, and inconsistent remodeling are challenges. TEVGs have the potential to meet all of the needs above, and several cellular or decellularized options are being evaluated, to produce materials that can mimic most aspects of native vasculature. Furthermore, understanding of the ability of these tissues to be remodeled by the host into a native tissue, and ability for that tissue to grow with patients who are young, will be important as the development of TEVG continues. Challenges are numerous, starting with creating the most effective process to mitigate or eliminate the immunogenic potential of these tissues, resolving the complexities of establishing bioengineering processes and platforms that follow the regulatory and quality guidelines, and achieving commercial-scale manufacturing to ultimately offer patients and surgical teams access to true replacement tissue and opening the way to multiple applications of organ replacement.Multiple teams have made substantial preclinical and clinical progress toward these goals, but further research and development is warranted to realize the potential futures of cardiovascular tissue engineering (Figure 3). Incorporation of computational modeling and systems biology approaches help better understand the intricate details of the genesis of tissue remodeling and vascular adaptation. Ultimately, bioengineering will offer replacement human organs and tissues in response to most chronic, degenerative, and autoimmune diseases, as well as traumatic injuries.
Article Information
Acknowledgments
We acknowledge the contribution of Rob Kirkton to this article and to the responses to the Editors and Reviewers’ comments. We also acknowledge the contributions of Ryan McKee in the conceptualization of Figures 2 and 3.
Sources of Funding
None.
Disclosures
L.E. Niklason is a founder, shareholder, President, and CEO of Humacyte, Inc, and serves on Humacyte’s Board of Directors. L.E. Niklason’s spouse is a shareholder of Humacyte, Inc, and serves on the Board of Directors. Y. Li, M.H. Kural, E.A. Hugentobler, J. Wang, and K.M. Naegeli are shareholders and employees of Humacyte, Inc.
Authors: Simon P Hoerstrup; Ian Cummings Mrcs; Mario Lachat; Frederick J Schoen; Rolf Jenni; Sebastian Leschka; Stefan Neuenschwander; Dörthe Schmidt; Anita Mol; Christina Günter; Mathias Gössi; Michele Genoni; Gregor Zund Journal: Circulation Date: 2006-07-04 Impact factor: 29.690
Authors: Ian Cummings; Sarah George; Jens Kelm; Doerthe Schmidt; Maximilian Y Emmert; Benedikt Weber; Gregor Zünd; Simon P Hoerstrup Journal: Eur J Cardiothorac Surg Date: 2012-01 Impact factor: 4.191
Authors: Zeeshan H Syedain; Melanie L Graham; Ty B Dunn; Timothy O'Brien; Sandra L Johnson; Robert J Schumacher; Robert T Tranquillo Journal: Sci Transl Med Date: 2017-11-01 Impact factor: 17.956
Authors: J W Quarmby; K G Burnand; S J Lockhart; A E Donald; K M Sommerville; C W Jamieson; N L Browse Journal: Br J Surg Date: 1998-06 Impact factor: 6.939