Literature DB >> 30846522

Patient-prosthesis mismatch following aortic valve replacement.

Rajdeep Bilkhu1, Marjan Jahangiri1, Catherine M Otto2.   

Abstract

Patient-prosthesis mismatch (PPM) occurs when an implanted prosthetic valve is too small for the patient; severe PPM is defined as an indexed effective orifice area (iEOA) <0.65 cm2/m2 following aortic valve replacement (AVR). This review examines articles from the past 10 years addressing the prevalence, outcomes and options for prevention and treatment of PPM after AVR. Prevalence of PPM ranges from 8% to almost 80% in individual studies. PPM is thought to have an impact on mortality, mainly in patients with severe PPM, although severe PPM accounts for only 10-15% of cases. Outcomes of patients with moderate PPM are not significantly different to those without PPM. PPM is associated with higher rates of perioperative stroke and renal failure and lack of left ventricular mass regression. Predictors include female sex, older age, hypertension, diabetes, renal failure and higher surgical risk score. PPM may be a marker of comorbidity rather than a risk factor for adverse outcomes. PPM should be suspected in patients with persistent cardiac symptoms after AVR when there is high prosthetic valve velocity or gradient and a small calculated effective orifice area. After exclusion of other causes of increased transvalvular gradient, re-intervention may be considered if symptoms persist and are unresponsive to medical therapy. However, this decision needs to consider the available options to relieve PPM and whether expected benefits justify the risk of intervention. The only effective intervention is redo surgery with implantation of a larger valve and/or annular enlargement. Therefore, focus needs to be on prevention. © Author(s) (or their employer(s)) 2019. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  aortic stenosis; transcatheter valve interventions; valve disease surgery

Mesh:

Year:  2019        PMID: 30846522     DOI: 10.1136/heartjnl-2018-313515

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  8 in total

Review 1.  How to Image and Manage Prosthesis-Related Complications After Transcatheter Aortic Valve Replacement.

Authors:  Nina C Wunderlich; Jörg Honold; Martin J Swaans; Robert J Siegel
Journal:  Curr Cardiol Rep       Date:  2021-07-01       Impact factor: 2.931

Review 2.  Prosthesis-patient mismatch after transcatheter aortic valve implantation.

Authors:  Masaki Miyasaka
Journal:  Cardiovasc Interv Ther       Date:  2022-06-16

Review 3.  TAVR: A Review of Current Practices and Considerations in Low-Risk Patients.

Authors:  Jenna Spears; Yousif Al-Saiegh; David Goldberg; Sina Manthey; Sheldon Goldberg
Journal:  J Interv Cardiol       Date:  2020-12-24       Impact factor: 2.279

4.  Hemodynamic Modeling of Biological Aortic Valve Replacement Using Preoperative Data Only.

Authors:  Florian Hellmeier; Jan Brüning; Simon Sündermann; Lina Jarmatz; Marie Schafstedde; Leonid Goubergrits; Titus Kühne; Sarah Nordmeyer
Journal:  Front Cardiovasc Med       Date:  2021-02-09

5.  Patient Prosthesis Mismatch After SAVR and TAVR.

Authors:  Sabine Bleiziffer; Tanja K Rudolph
Journal:  Front Cardiovasc Med       Date:  2022-03-30

6.  Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis.

Authors:  Max Potratz; Kawa Mohemed; Hazem Omran; Lasha Gortamashvili; Kai Peter Friedrichs; Werner Scholtz; Smita Scholtz; Volker Rudolph; Cornelia Piper; Tomasz Gilis-Januszewski; René Schramm; Nobuyuki Furukawa; Jan Gummert; Sabine Bleiziffer; Tanja Katharina Rudolph
Journal:  J Clin Med       Date:  2022-08-05       Impact factor: 4.964

7.  Perceval or Trifecta to Prevent Patient-Prosthesis Mismatch.

Authors:  Daniel Hernandez-Vaquero; Carlota Vigil-Escalera; Yvan Persia; Carlos Morales; Isaac Pascual; Alberto Domínguez-Rodríguez; Emiliano Rodríguez-Caulo; Manuel Carnero; Rocío Díaz; Pablo Avanzas; Cesar Moris; Jacobo Silva
Journal:  J Clin Med       Date:  2020-09-14       Impact factor: 4.241

8.  Aortic prosthetic size predictor in aortic valve replacement.

Authors:  Anh Tuan Vo; Tomomi Nakajima; Trang Thi Thu Nguyen; Nguyen Thoi Hai Nguyen; Nga Bich Le; Tri Huu Cao; Dinh Hoang Nguyen
Journal:  J Cardiothorac Surg       Date:  2021-08-04       Impact factor: 1.637

  8 in total