Literature DB >> 35699155

Metabolism of oxygen via T2 and interleaved velocity encoding: A rapid method to quantify whole-brain cerebral metabolic rate of oxygen.

Rajiv S Deshpande1, Michael C Langham1, Cheng-Chieh Cheng1, Felix W Wehrli1.   

Abstract

PURPOSE: Cerebral metabolic rate of oxygen (CMRO2 ) is an important biomarker of brain function. Key physiological parameters required to quantify CMRO2 include blood flow rate in the feeding arteries and venous oxygen saturation (SvO2 ) in the draining vein. Here, a pulse sequence, metabolism of oxygen via T2 and interleaved velocity encoding (MOTIVE), was developed to measure both parameters simultaneously and enable CMRO2 quantification in a single pass.
METHODS: The MOTIVE sequence interleaves a phase-contrast module between a nonselective saturation and a background-suppressed T2 -prepared EPI readout (BGS-EPI) to measure T2 of blood water protons and cerebral blood flow in 20 s or less. The MOTIVE and standalone BGS-EPI sequences were compared against TRUST ("T2 relaxation under spin tagging") in the brain in healthy subjects (N = 24). Variants of MOTIVE to enhance resolution or shorten scan time were explored. Intrasession and intersession reproducibility studies were performed.
RESULTS: MOTIVE experiments yielded an average SvO2 of 61 ± 6% in the superior sagittal sinus of the brain and an average cerebral blood flow of 56 ± 10 ml/min/100 g. The bias in SvO2 of MOTIVE and BGS-EPI to TRUST was +2 ± 4% and +1 ± 3%, respectively. The bias in cerebral blood flow of MOTIVE to Cartesian phase-contrast reference was +1 ± 6 ml/min/100 g.
CONCLUSIONS: The MOTIVE sequence is an advance over existing T2 -based oximetric methods. It does not require a control image and simultaneously measures SvO2 and flow velocity. The measurements agree well with TRUST and reference phase-contrast sequences. This noninvasive technique enables CMRO2 quantification in under 20 s and is reproducible for in vivo applications.
© 2022 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  T2-based oximetry; TRUST; oxygen metabolism; venous oxygen saturation

Mesh:

Substances:

Year:  2022        PMID: 35699155      PMCID: PMC9247043          DOI: 10.1002/mrm.29299

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   3.737


  31 in total

1.  Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla.

Authors:  Hanzhang Lu; Chekesha Clingman; Xavier Golay; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2004-09       Impact factor: 4.668

2.  MRI estimation of global brain oxygen consumption rate.

Authors:  Varsha Jain; Michael C Langham; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2010-04-21       Impact factor: 6.200

3.  MR susceptometry for measuring global brain oxygen extraction.

Authors:  María A Fernández-Seara; Aranee Techawiboonwong; John A Detre; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

4.  THE EFFECTS OF ALTERED ARTERIAL TENSIONS OF CARBON DIOXIDE AND OXYGEN ON CEREBRAL BLOOD FLOW AND CEREBRAL OXYGEN CONSUMPTION OF NORMAL YOUNG MEN.

Authors:  S S Kety; C F Schmidt
Journal:  J Clin Invest       Date:  1948-07       Impact factor: 14.808

5.  1991 I.I. Rabi Award. Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T.

Authors:  G A Wright; B S Hu; A Macovski
Journal:  J Magn Reson Imaging       Date:  1991 May-Jun       Impact factor: 4.813

6.  Validation of T2 -based oxygen extraction fraction measurement with 15 O positron emission tomography.

Authors:  Dengrong Jiang; Shengwen Deng; Crystal G Franklin; Michael O'Boyle; Wei Zhang; Betty L Heyl; Li Pan; Paul A Jerabek; Peter T Fox; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2020-07-08       Impact factor: 4.668

7.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

Authors:  Terry K Koo; Mae Y Li
Journal:  J Chiropr Med       Date:  2016-03-31

8.  Pulse sequence programming in a dynamic visual environment: SequenceTree.

Authors:  Jeremy F Magland; Cheng Li; Michael C Langham; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2015-03-07       Impact factor: 4.668

9.  Vessel-specific quantification of blood oxygenation with T2-relaxation-under-phase-contrast MRI.

Authors:  Lisa C Krishnamurthy; Peiying Liu; Yulin Ge; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

10.  Whole-brain 3D mapping of oxygen metabolism using constrained quantitative BOLD.

Authors:  Hyunyeol Lee; Felix W Wehrli
Journal:  Neuroimage       Date:  2022-01-29       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.