Literature DB >> 35685237

Sliding Hip Screw and Side Plate for Intertrochanteric Hip Fractures.

Yushane Shih1, Nicholas I Bartschat1, Edward Y Cheng1.   

Abstract

For stable intertrochanteric hip fractures, treatment commonly involves the use of a sliding hip screw. Intertrochanteric hip fractures are increasingly common as the population ages and lives longer. More than 250,000 hip fractures occur per year in the United States1. The mortality rate within the first year following operative treatment ranges from 14% to 27.3%2,3. Early surgical repair within 48 hours of injury is associated with a lower risk of mortality2,4,5. The goals of surgical treatment are restoration of coronal plane alignment without varus angulation and early patient mobilization. Description: The sliding hip screw procedure can be divided into (1) preoperative planning; (2) patient positioning; (3) C-arm setup; (4) closed reduction of fracture; (5) sterile preparation and draping; (6) lateral hip approach; (7) guide pin insertion; (8) triple-reaming the proximal aspect of the femur; (9) sliding hip screw insertion into the femoral neck and head; (10) side plate insertion, engaging the sliding hip screw, and fixation to the femur; (11) lag compression screw insertion (if appropriate); and (12) final fluoroscopic images and wound closure. Alternatives: Intertrochanteric hip fractures must be surgically treated to avoid morbidity and increased risk of mortality. Nonoperative treatment is occasionally indicated in nonambulatory patients or those with high perioperative risk. If treated surgically, a common alternative implant option includes the intramedullary nail. Finally, for severely comminuted fractures or failed internal fixation, total hip arthroplasty may be necessary. Rationale: Sliding hip screws are as effective as intramedullary nails and often less costly6. In general, the quality of fracture reduction is more critical than the choice of implant7. A prospective study found no significant difference in walking ability with either sliding hip screws or intramedullary nails for stable intertrochanteric fractures8. Expected Outcomes: By 6 months, the majority of fractures will have healed; according to a prospective randomized study, 91% of stable fractures and 85% of unstable fractures had achieved radiographic union by that time9. Another study showed radiographically healed fractures in all 106 patients treated with sliding hip screws at median follow-up of 13.6 months8. Important Tips: Watch out for comminution of the greater or lesser trochanter, which may require supplemental fixation.Prior to completely reflecting the vastus lateralis muscle, control the bleeding from any perforators with use of 2-0 silk ties. This prevents recurrent bleeding, which often occurs if only cautery is utilized to coagulate these vessels.Utilize a 4.5-mm drill hole in the lateral cortex of the femur in order to allow for minor adjustments of the anterior femoral neck guide pin; otherwise, the pin will be held tightly and continue to be bound in the same direction by the lateral cortex on repeated attempts.If the guide pin is inadvertently withdrawn along with the reamer after reaming, a lag screw may be placed backward in the newly reamed hole and the guide pin passed back through the lag screw to reposition it.Extracapsular hip fractures should be carefully scrutinized for signs of instability, such as lateral wall comminution or reverse obliquity. The fracture may displace posteriorly when the patient is supine on the fracture table.While placing the guidewire, multiple entry attempts can weaken the lateral cortex and propagate the fracture into the subtrochanteric region.Superior placement of the lag screw results in poor tip-apex distance and a higher chance of screw cut-out.Be careful to prevent guidewire penetration into the hip joint.Loss of reduction or femoral head malrotation may occur during lag screw insertion. Acronyms & Abbreviations: AP = anteroposteriorfx's = fracturesIMN = intramedullary nailIV = intravenousPDS = polydioxanone sutureSHS = sliding hip screwTFL = tensor fascia lata.
Copyright © 2022 by The Journal of Bone and Joint Surgery, Incorporated.

Entities:  

Year:  2022        PMID: 35685237      PMCID: PMC9173521          DOI: 10.2106/JBJS.ST.19.00038

Source DB:  PubMed          Journal:  JBJS Essent Surg Tech        ISSN: 2160-2204


  8 in total

Review 1.  Effect of early surgery after hip fracture on mortality and complications: systematic review and meta-analysis.

Authors:  Nicole Simunovic; P J Devereaux; Sheila Sprague; Gordon H Guyatt; Emil Schemitsch; Justin Debeer; Mohit Bhandari
Journal:  CMAJ       Date:  2010-09-13       Impact factor: 8.262

2.  Impact of comorbidities on hospitalization costs following hip fracture.

Authors:  Lucas E Nikkel; Edward J Fox; Kevin P Black; Charles Davis; Lucille Andersen; Christopher S Hollenbeak
Journal:  J Bone Joint Surg Am       Date:  2012-01-04       Impact factor: 5.284

3.  Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail.

Authors:  A Lizaur Utrilla; J Sanz Reig; F Miralles Muñoz; C Bendala Tufanisco
Journal:  J Orthop Trauma       Date:  2005-04       Impact factor: 2.512

4.  Cost-effectiveness analysis of fixation options for intertrochanteric hip fractures.

Authors:  Eric Swart; Eric C Makhni; William Macaulay; Melvin P Rosenwasser; Kevin J Bozic
Journal:  J Bone Joint Surg Am       Date:  2014-10-01       Impact factor: 5.284

Review 5.  Implant options for the treatment of intertrochanteric fractures of the hip: rationale, evidence, and recommendations.

Authors:  A R Socci; N E Casemyr; M P Leslie; M R Baumgaertner
Journal:  Bone Joint J       Date:  2017-01       Impact factor: 5.082

6.  Postoperative complications and mortality associated with operative delay in older patients who have a fracture of the hip.

Authors:  J D Zuckerman; M L Skovron; K J Koval; G Aharonoff; V H Frankel
Journal:  J Bone Joint Surg Am       Date:  1995-10       Impact factor: 5.284

7.  A randomized study of the compression hip screw and Gamma nail in 426 fractures.

Authors:  Leif Ahrengart; Hans Törnkvist; Per Fornander; Karl-Göran Thorngren; Lauri Pasanen; Per Wahlström; Seppo Honkonen; Urban Lindgren
Journal:  Clin Orthop Relat Res       Date:  2002-08       Impact factor: 4.176

8.  Mortality and cause of death in hip fracture patients aged 65 or older: a population-based study.

Authors:  Jorma Panula; Harri Pihlajamäki; Ville M Mattila; Pekka Jaatinen; Tero Vahlberg; Pertti Aarnio; Sirkka-Liisa Kivelä
Journal:  BMC Musculoskelet Disord       Date:  2011-05-20       Impact factor: 2.362

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.