Literature DB >> 12151898

A randomized study of the compression hip screw and Gamma nail in 426 fractures.

Leif Ahrengart1, Hans Törnkvist, Per Fornander, Karl-Göran Thorngren, Lauri Pasanen, Per Wahlström, Seppo Honkonen, Urban Lindgren.   

Abstract

A prospective, randomized study comparing the compression hip screw with the Gamma nail in the treatment of 426 intertrochanteric fractures is reported. The median patient age was 80 years, and 71% were women The compression hip screw operation took less time except in Evans Type 5 fractures. Blood loss generally was less in the compression hip screw group except in patients with Type 5 fractures. The most frequent surgical problem for patients in the Gamma group was problems with distal locking. Cephalic position of the femoral head screw and cut-out were seen more often in the Gamma nail group. The Gamma nail more frequently preserved the fracture position obtained perioperatively. Whether there was distal locking of the Gamma nail in unstable fractures did not seem to affect the healing rate. Additional fissures or fractures in the proximal femur occurred during five Gamma nail operations and two compression hip screw operations. Postoperative walking ability did not differ between the groups. At 6 months 88% of the fractures were healed. In less comminuted fractures, the compression hip screw method is the preferred method of treatment whereas the Gamma nail is an alternative treatment for more comminuted Evans Type 5 fractures.

Entities:  

Mesh:

Year:  2002        PMID: 12151898     DOI: 10.1097/00003086-200208000-00024

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  54 in total

1.  Comparison of functional recovery in the very early period after surgery between plate and nail fixation for correction of stable femoral intertrochanteric fractures: a controlled clinical trial of 18 patients.

Authors:  Koun Yamauchi; Kazunari Fushimi; Goshi Shirai; Masashi Fukuta
Journal:  Geriatr Orthop Surg Rehabil       Date:  2014-06

2.  Implant-related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices.

Authors:  L Audigé; B Hanson; M F Swiontkowski
Journal:  Int Orthop       Date:  2003-05-07       Impact factor: 3.075

Review 3.  Fractures in brief: intertrochanteric hip fractures.

Authors:  Jaimo Ahn; Joseph Bernstein
Journal:  Clin Orthop Relat Res       Date:  2010-05       Impact factor: 4.176

Review 4.  [Pertrochanteric femoral fractures in the elderly].

Authors:  G H Sandmann; P Biberthaler
Journal:  Unfallchirurg       Date:  2015-05       Impact factor: 1.000

5.  A comparison of two fixation methods for femoral trochanteric fractures: a new generation intramedullary system vs sliding hip screw.

Authors:  Christian Carulli; Federico Piacentini; Tommaso Paoli; Roberto Civinini; Massimo Innocenti
Journal:  Clin Cases Miner Bone Metab       Date:  2017-05-30

6.  3066 consecutive Gamma Nails. 12 years experience at a single centre.

Authors:  Alicja J Bojan; Claudia Beimel; Andreas Speitling; Gilbert Taglang; Carl Ekholm; Anders Jönsson
Journal:  BMC Musculoskelet Disord       Date:  2010-06-26       Impact factor: 2.362

Review 7.  Intertrochanteric fractures: a review of fixation methods.

Authors:  Senthil Nathan Sambandam; Jayadev Chandrasekharan; Varatharaj Mounasamy; Cyril Mauffrey
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-03-30

8.  Pitfalls and complications in the use of the proximal femoral nail.

Authors:  Joachim Windolf; Dirk A Hollander; Mohssen Hakimi; Wolfgang Linhart
Journal:  Langenbecks Arch Surg       Date:  2004-04-15       Impact factor: 3.445

9.  CORR Insights™: Intramedullary nails result in more reoperations than sliding hip screws in two-part intertrochanteric fractures.

Authors:  Paul J Dougherty
Journal:  Clin Orthop Relat Res       Date:  2013-04       Impact factor: 4.176

10.  Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation.

Authors:  George K Kouvidis; Mark B Sommers; Peter V Giannoudis; Pavlos G Katonis; Michael Bottlang
Journal:  J Orthop Surg Res       Date:  2009-05-18       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.