Literature DB >> 35655745

Outcomes Following Different Fixation Strategies of Neer Type IIB Distal Clavicle Fractures.

Michael J Gutman1, Christopher D Joyce1, Manan S Patel1, Mark D Lazarus1, John G Horneff2.   

Abstract

Background: Multiple surgical techniques for fixation of Neer type IIB distal clavicle fractures have been described without consensus on optimal treatment. The purpose of this study is to compare functional and radiographic results with surgical management of Neer type IIB distal clavicle fractures at a single institution.
Methods: Sixty-three patients with acute Neer type IIB fractures treated operatively were evaluated. Patients with a minimum of two year follow up were included. Functional scores included American Shoulder and Elbow Surgeons (ASES), Single Assessment Numeric Evaluation (SANE), Simple Shoulder Test (SST), and Likert patient satisfaction (1 to 5). Radiographs were assessed for osseous union and coracoclavicular (CC) distance.
Results: Thirty-eight patients met inclusion with a mean follow-up of 5.3 years. Patients were divided into five groups based on fixation technique: suture-only CC fixation (n=6), CC screw fixation only (n=3), open reduction internal fixation (ORIF) without CC fixation (n=8), hook plate fixation (n=4), and ORIF with suture CC reconstruction (n=17). Outcome scores for the entire cohort were 91.8 for ASES, 90.2 for SANE, and 10.8 for STT. Patients with hook plates had significantly lower SANE score (p=0.016), but no other significant differences in functional, satisfaction, or radiographic outcomes were found between groups. Sixteen patients (42.1%) required reoperation.
Conclusion: Treatment of Neer type IIB fractures via suture- only fixation, plate-only fixation, or a combination of both demonstrated satisfactory mid to long term outcomes. While implant removal was more common in the CC screw and ORIF groups, no fixation technique proved functionally superior.

Entities:  

Keywords:  Acromioclavicular separation; Bosworth screw; Clavicle fracture; Hook plate; Locking plate; Neer IIB distal clavicle fracture; Suture repair

Year:  2022        PMID: 35655745      PMCID: PMC9117897          DOI: 10.22038/ABJS.2021.54472.2718

Source DB:  PubMed          Journal:  Arch Bone Jt Surg        ISSN: 2345-461X


  27 in total

1.  Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support.

Authors:  Paul A Harris; Robert Taylor; Robert Thielke; Jonathon Payne; Nathaniel Gonzalez; Jose G Conde
Journal:  J Biomed Inform       Date:  2008-09-30       Impact factor: 6.317

Review 2.  Comparison of the efficacy of a distal clavicular locking plate versus a clavicular hook plate in the treatment of unstable distal clavicle fractures and a systematic literature review.

Authors:  Chunlin Zhang; Junwu Huang; Yi Luo; Hua Sun
Journal:  Int Orthop       Date:  2014-04-15       Impact factor: 3.075

3.  Complications after surgical treatment of distal clavicle fractures.

Authors:  Anshuman Singh; Mark Schultzel; John F Fleming; Ronald A Navarro
Journal:  Orthop Traumatol Surg Res       Date:  2019-06-13       Impact factor: 2.256

4.  Precontoured locking plate fixation for displaced lateral clavicle fractures.

Authors:  Sang Ki Lee; Jae Won Lee; Dae Geon Song; Won Sik Choy
Journal:  Orthopedics       Date:  2013-06       Impact factor: 1.390

5.  Fixation method for treatment of unstable distal clavicle fracture: systematic review and network meta-analysis.

Authors:  Manusak Boonard; Sermsak Sumanont; Alisara Arirachakaran; Eakachit Sikarinkul; Pichet Ratanapongpean; Wichan Kanchanatawan; Jatupon Kongtharvonskul
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-03-22

Review 6.  Treatment of distal clavicle fracture: a systematic review of treatment modalities in 425 fractures.

Authors:  Joo Han Oh; Sae Hoon Kim; Jung Ha Lee; Seung Han Shin; Hyun Sik Gong
Journal:  Arch Orthop Trauma Surg       Date:  2010-10-22       Impact factor: 3.067

7.  Management of unstable distal third clavicle fractures: clinical and radiological outcomes of the arthroscopy-assisted conoid ligament reconstruction and fracture cerclage with sutures.

Authors:  Luis Natera Cisneros; Juan Sarasquete Reiriz
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-02-22

8.  A biomechanical comparison of distal clavicle fracture reconstructive techniques.

Authors:  Julie Y Bishop; Michael Roesch; Brian Lewis; Grant L Jones; Alan S Litsky
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2013-03

9.  The clavicle hook plate for Neer type II lateral clavicle fractures.

Authors:  R J Renger; G R Roukema; J C Reurings; P M Raams; J Font; E J M M Verleisdonk
Journal:  J Orthop Trauma       Date:  2009-09       Impact factor: 2.512

10.  Fixation of unstable type II clavicle fractures with distal clavicle plate and suture button.

Authors:  Peter S Johnston; Benjamin W Sears; Mark R Lazarus; Barbara G Frieman
Journal:  J Orthop Trauma       Date:  2014-11       Impact factor: 2.512

View more