| Literature DB >> 24667803 |
Peter S Johnston1, Benjamin W Sears, Mark R Lazarus, Barbara G Frieman.
Abstract
This article reports on a technique to treat unstable type II distal clavicle fractures using fracture-specific plates and coracoclavicular augmentation with a suture button. Six patients with clinically unstable type II distal clavicle fractures underwent treatment using the above technique. All fractures demonstrated radiographic union at 9.6 (8.4-11.6) weeks with a mean follow-up of 15.6 (12.4-22.3) months. American Shoulder and Elbow Surgeons, Penn Shoulder Score, and Single Assessment Numeric Evaluation scores were 97.97 (98.33-100), 96.4 (91-99), and 95 (90-100), respectively. One patient required implant removal. Fracture-specific plating with suture-button augmentation for type II distal clavicle fractures provides reliable rates of union without absolute requirement for implant removal.Entities:
Mesh:
Year: 2014 PMID: 24667803 DOI: 10.1097/BOT.0000000000000081
Source DB: PubMed Journal: J Orthop Trauma ISSN: 0890-5339 Impact factor: 2.512