Abstract

OBJECTIVE: To evaluate functional and radiologic outcome in patients with a Neer type II lateral clavicle fracture treated with the clavicle hook plate.
DESIGN: Multicenter retrospective study.
SETTING: Five level I and II trauma centers. PATIENTS: Forty-four patients, average age 38.4 years (18-66 years), with a Neer type II lateral clavicle fracture treated with the clavicle hook plate between January 1, 2003, and December 31, 2006. INTERVENTION: Open reduction and internal fixation with the clavicle hook plate. Removal of all 44 implants after consolidation at a mean of 8.4 months (2-33 months) postoperatively. MAIN OUTCOME MEASUREMENTS: At an average follow-up of 27.4 months (13-48 months), functional outcome was assessed with the Constant-Murley scoring system. Radiographs were taken to evaluate consolidation and to determine the distance between the coracoid process and the clavicle.
RESULTS: The average Constant score was 92.4 (74-100). The average distance between the coracoid process and the clavicle was 9.8 mm (7.3-14.8 mm) compared with 9.4 mm (6.9-14.3 mm) on the contralateral nonoperative side. We observed 1 dislocation of an implant (2.2%), 2 cases of pseudarthrosis (4.5%), 2 superficial wound infections (4.5%), 2 patients with hypertrophic scar tissue (4.5%), and 3 times an acromial osteolysis (6.8%). Thirty patients (68%) reported discomfort due to the implant. These implant-related complaints and the acromial osteolysis disappeared after removal of the hook plate. With all the patients, direct functional aftercare was possible.
CONCLUSIONS: The clavicle hook plate is a suitable implant for Neer type II clavicle fractures. The advantage of this osteosynthesis is the possibility of immediate functional aftercare. We observed a high percentage of discomfort due to the implant; therefore, we advise to remove the implant as soon as consolidation has taken place.

Entities:  

Mesh:

Year:  2009        PMID: 19704272     DOI: 10.1097/BOT.0b013e318193d878

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  28 in total

1.  Biomechanical analysis of acromioclavicular joint dislocation treated with clavicle hook plates in different lengths.

Authors:  Cheng-Min Shih; Kui-Chou Huang; Chien-Chou Pan; Cheng-Hung Lee; Kuo-Chih Su
Journal:  Int Orthop       Date:  2015-07-17       Impact factor: 3.075

2.  Complications with the clavicle hook plate after fixation of Neer type II clavicle fractures.

Authors:  Yaiza Lopiz; Pablo Checa; Carlos García-Fernández; Jose Valle; Maria Luisa Vega; Fernando Marco
Journal:  Int Orthop       Date:  2018-08-16       Impact factor: 3.075

Review 3.  Comparison of the efficacy of a distal clavicular locking plate versus a clavicular hook plate in the treatment of unstable distal clavicle fractures and a systematic literature review.

Authors:  Chunlin Zhang; Junwu Huang; Yi Luo; Hua Sun
Journal:  Int Orthop       Date:  2014-04-15       Impact factor: 3.075

Review 4.  Hook plate fixation of acute displaced lateral clavicle fractures: mid-term results and a brief literature overview.

Authors:  Davut Tiren; Alexander J M van Bemmel; Dingeman J Swank; Frits M van der Linden
Journal:  J Orthop Surg Res       Date:  2012-01-11       Impact factor: 2.359

Review 5.  Fracture of distal end clavicle: A review.

Authors:  Balaji Sambandam; Rajat Gupta; Santosh Kumar; Lalit Maini
Journal:  J Clin Orthop Trauma       Date:  2014-06-19

6.  [Clavicular hook plate with coracoclavicular ligament augmentation by suture anchor in the treatment of unstable distal clavicle fractures].

Authors:  Shuang Wu; Jialei Chen; Jie Zhang; Shakya Sujan; Fei Xing; Zhou Xiang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-08-15

7.  [Fractures of the lateral clavicle and acromion].

Authors:  R Meller; C Krettek
Journal:  Unfallchirurg       Date:  2012-10       Impact factor: 1.000

8.  Evaluation of the use of the hook plate in Neer type 2 lateral clavicle fractures and Rockwood types 3-5 acromioclavicular joint dislocations.

Authors:  C C Drijfhout van Hooff; R Haverlag; W J Willems
Journal:  Eur J Trauma Emerg Surg       Date:  2013-06-27       Impact factor: 3.693

9.  The clinical outcome of the 'Surgilig' technique for the reconstruction of acromioclavicular dislocations: A systematic review.

Authors:  Michael-Alexander Malahias; Thomas Sarlikiotis; Emmanouil Brilakis; Dimitrios Gerogiannis; Grigorios Avramidis; Emmanouil Antonogiannakis
Journal:  J Orthop       Date:  2019-09-11

10.  Clinical outcomes of a combined osteoligamentous reconstruction technique of Neer Type IIB distal clavicle fractures.

Authors:  Cody R Perskin; Nirmal C Tejwani; Laith M Jazrawi; Philipp Leucht; Kenneth A Egol
Journal:  J Orthop       Date:  2021-05-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.