Barbara S Brunner1, Nikolaus Luft1, Siegfried G Priglinger1, Mehdi Shajari1,2, Wolfgang J Mayer1, Stefan Kassumeh1.
Abstract
BACKGROUND: To determine whether there is a significant saving of time when using a digital cataract workflow for digital data transfer compared to a manual approach of biometry assessment, data export, intraocular lens calculation, and surgery time.Entities:
Keywords: cataract surgery; cataract surgery workflow; clear lens exchange; efficiency; refractive lens exchange; refractive surgery; toric intraocular lens
Year: 2022 PMID: 35629035 PMCID: PMC9147456 DOI: 10.3390/jcm11102907
Source DB: PubMed Journal: J Clin Med ISSN: 2077-0383 Impact factor: 4.964
Workflow steps and points of interest in the manual and digital group.
| Manual Group ( | Digital Group ( |
|---|---|
| Data check | EQ Workplace data check |
| IOL calculation (IOLMaster 700) | IOL calculation (EQ Workplace) |
| Export of reference image to USB memory stick | Digital reference image export via FORUM to CALLISTO eye |
| Import reference image to CALLISTO eye and image matching | Digital reference image import via FORUM to CALLISTO eye and image matching |
| IOL alignment using CALLISTO eye and Z ALIGN tracking system | |
| Overall surgery time | |
| Overall diagnostic + surgery time | |
Time measurements at the time points of interest in the manual and digital group.
| Time Point of Interest | Time, Manual Group ( | Time, Digital Group (EQ Workplace) Group ( | Level of Significance |
|---|---|---|---|
| Data check and IOL calculation | 76.7 ± 12.3 | 48.0 ± 16.1 | |
| Reference image export | 26.8 ± 5.5 | ||
| Reference image import and image matching | 129.8 ± 18.0 | 54.9 ± 9.2 | |
| IOL alignment intraoperatively | 30.7 ± 4.1 | 22.8 ± 5.1 | |
| Surgery time (overall) | 756.5 ± 82.3 | 667.3 ± 56.3 | |
| Diagnostic and surgical time (overall) | 1364.1 ± 202.6 | 1125.8 ± 183.2 |
Figure 1Cumulative histogram of the magnitudes of the preoperative corneal astigmatism and the postoperative refractive astigmatism at the corneal plane in the digital group (n = 24).
Figure 2Double-angle plots of preoperative corneal astigmatism (TCRP) and postoperative refractive cylinder in the digital group (n = 24).