Literature DB >> 35614851

Precision in iterative modulation enhanced single-molecule localization microscopy.

Dylan Kalisvaart1, Jelmer Cnossen2, Shih-Te Hung2, Sjoerd Stallinga3, Michel Verhaegen2, Carlas S Smith4.   

Abstract

Modulation enhanced single-molecule localization microscopy (meSMLM) methods improve the localization precision by using patterned illumination to encode additional position information. Iterative meSMLM (imeSMLM) methods iteratively generate prior information on emitter positions, used to locally improve the localization precision during subsequent iterations. The Cramér-Rao lower bound cannot incorporate prior information to bound the best achievable localization precision because it requires estimators to be unbiased. By treating estimands as random variables with a known prior distribution, the Van Trees inequality (VTI) can be used to bound the best possible localization precision of imeSMLM methods. An imeSMLM method is considered, where the positions of in-plane standing-wave illumination patterns are controlled over the course of multiple iterations. Using the VTI, we analytically approximate a lower bound on the maximum localization precision of imeSMLM methods that make use of standing-wave illumination patterns. In addition, we evaluate the maximally achievable localization precision for different illumination pattern placement strategies using Monte Carlo simulations. We show that in the absence of background and under perfect modulation, the information content of signal photons increases exponentially as a function of the iteration count. However, the information increase is no longer exponential as a function of the iteration count under non-zero background, imperfect modulation, or limited mechanical resolution of the illumination positioning system. As a result, imeSMLM with two iterations reaches at most a fivefold improvement over SMLM at 8 expected background photons per pixel and 95% modulation contrast. Moreover, the information increase from imeSMLM is balanced by a reduced signal photon rate. Therefore, SMLM outperforms imeSMLM when considering an equal measurement time and illumination power per iteration. Finally, the VTI is an excellent tool for the assessment of the performance of illumination control and is therefore the method of choice for optimal design and control of imeSMLM methods.
Copyright © 2022 Biophysical Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2022        PMID: 35614851      PMCID: PMC9279351          DOI: 10.1016/j.bpj.2022.05.027

Source DB:  PubMed          Journal:  Biophys J        ISSN: 0006-3495            Impact factor:   3.699


  14 in total

1.  Localization accuracy in single-molecule microscopy.

Authors:  Raimund J Ober; Sripad Ram; E Sally Ward
Journal:  Biophys J       Date:  2004-02       Impact factor: 4.033

2.  Imaging intracellular fluorescent proteins at nanometer resolution.

Authors:  Eric Betzig; George H Patterson; Rachid Sougrat; O Wolf Lindwasser; Scott Olenych; Juan S Bonifacino; Michael W Davidson; Jennifer Lippincott-Schwartz; Harald F Hess
Journal:  Science       Date:  2006-08-10       Impact factor: 47.728

3.  MINFLUX nanoscopy delivers 3D multicolor nanometer resolution in cells.

Authors:  Klaus C Gwosch; Jasmin K Pape; Francisco Balzarotti; Philipp Hoess; Jan Ellenberg; Jonas Ries; Stefan W Hell
Journal:  Nat Methods       Date:  2020-01-13       Impact factor: 28.547

4.  Molecular resolution imaging by repetitive optical selective exposure.

Authors:  Lusheng Gu; Yuanyuan Li; Shuwen Zhang; Yanhong Xue; Weixing Li; Dong Li; Tao Xu; Wei Ji
Journal:  Nat Methods       Date:  2019-09-09       Impact factor: 28.547

5.  SIMPLE: Structured illumination based point localization estimator with enhanced precision.

Authors:  Loïc Reymond; Johannes Ziegler; Christian Knapp; Fung-Chen Wang; Thomas Huser; Verena Ruprecht; Stefan Wieser
Journal:  Opt Express       Date:  2019-08-19       Impact factor: 3.894

6.  Precision in iterative modulation enhanced single-molecule localization microscopy.

Authors:  Dylan Kalisvaart; Jelmer Cnossen; Shih-Te Hung; Sjoerd Stallinga; Michel Verhaegen; Carlas S Smith
Journal:  Biophys J       Date:  2022-05-25       Impact factor: 3.699

Review 7.  Super-resolution fluorescence microscopy.

Authors:  Bo Huang; Mark Bates; Xiaowei Zhuang
Journal:  Annu Rev Biochem       Date:  2009       Impact factor: 23.643

8.  Molecular-scale axial localization by repetitive optical selective exposure.

Authors:  Lusheng Gu; Yuanyuan Li; Shuwen Zhang; Maoge Zhou; Yanhong Xue; Weixing Li; Tao Xu; Wei Ji
Journal:  Nat Methods       Date:  2021-04-01       Impact factor: 28.547

9.  Localization microscopy at doubled precision with patterned illumination.

Authors:  Jelmer Cnossen; Taylor Hinsdale; Rasmus Ø Thorsen; Marijn Siemons; Florian Schueder; Ralf Jungmann; Carlas S Smith; Bernd Rieger; Sjoerd Stallinga
Journal:  Nat Methods       Date:  2019-12-09       Impact factor: 28.547

10.  MINSTED fluorescence localization and nanoscopy.

Authors:  Michael Weber; Marcel Leutenegger; Stefan Stoldt; Stefan Jakobs; Tiberiu S Mihaila; Alexey N Butkevich; Stefan W Hell
Journal:  Nat Photonics       Date:  2021-03-15       Impact factor: 38.771

View more
  2 in total

1.  Prior information improves resolution.

Authors:  Alexander R Small
Journal:  Biophys J       Date:  2022-05-27       Impact factor: 3.699

2.  Precision in iterative modulation enhanced single-molecule localization microscopy.

Authors:  Dylan Kalisvaart; Jelmer Cnossen; Shih-Te Hung; Sjoerd Stallinga; Michel Verhaegen; Carlas S Smith
Journal:  Biophys J       Date:  2022-05-25       Impact factor: 3.699

  2 in total