Literature DB >> 35547098

Development of Low-Cost and Portable Pulse Oximeter Device with Improved Accuracy and Accessibility.

Hundessa Daba Nemomssa1, Hakkins Raj1.   

Abstract

Purpose: In a clinical setting, blood oxygen saturation is one of the most important vital sign indicators. A pulse oximeter is a device that measures the blood oxygen saturation and pulse rate of patients with various disorders. However, due to ethical concerns, commercially available pulse oximeters are limited in terms of calibration on critically sick patients, resulting in a significant error rate for measurement in the critical oxygen saturation range. The device's accessibility in developing countries' healthcare settings is also limited due to portability, cost implications, and a lack of recognized need. The purpose of this study was to develop a reliable, low-cost, and portable pulse oximeter device with improved accuracy in the critical oxygen saturation range.
Methods: The proposed device measures oxygen saturation and heart rate using the reflectance approach. The rechargeable battery and power supply from the smartphone were taken into account, and the calibration in critical oxygen saturation values was performed using Prosim 8 vital sign simulator, and by comparing with a standard pulse oximeter device over fifteen iterations.
Results: The device's prototype was successfully developed and tested. Oxygen saturation and heart rate readings were both accurate to 97.74% and 97.37%, respectively, compared with the simulator, and an accuracy of 98.54% for the measurement of blood oxygen saturation was obtained compared with the standard device.
Conclusion: The accuracy of oxygen measurement attained in this study is significant for measuring oxygen saturation for patients in critical care, anesthesia, pre-operative and post-operative surgery, and COVID-19 patients. The advancements made in this research have the potential to increase the accessibility of pulse oximeter in resource limited areas.
© 2022 Nemomssa and Raj.

Entities:  

Keywords:  accuracy; blood oxygen saturation; critical oxygen saturation range; low-cost; portable; pulse oximeter

Year:  2022        PMID: 35547098      PMCID: PMC9084508          DOI: 10.2147/MDER.S366053

Source DB:  PubMed          Journal:  Med Devices (Auckl)        ISSN: 1179-1470


  35 in total

Review 1.  Pulse oximetry: A reliable and cost effective screening tool in children with pneumonia for developing countries.

Authors:  Muhammad Akhter Hamid; Ayesha Chandna; Sohaib Siddiqui; Jabeen Fayyaz
Journal:  J Pak Med Assoc       Date:  2016-08       Impact factor: 0.781

2.  The accuracy of pulse oximetry in emergency department patients with severe sepsis and septic shock: a retrospective cohort study.

Authors:  Ben J Wilson; Hamish J Cowan; Jason A Lord; Dan J Zuege; David A Zygun
Journal:  BMC Emerg Med       Date:  2010-05-05

Review 3.  Oxygen therapy in critical illness: precise control of arterial oxygenation and permissive hypoxemia.

Authors:  Daniel Stuart Martin; Michael Patrick William Grocott
Journal:  Crit Care Med       Date:  2013-02       Impact factor: 7.598

Review 4.  Pulse oximetry for perioperative monitoring.

Authors:  Tom Pedersen; Amanda Nicholson; Karen Hovhannisyan; Ann Merete Møller; Andrew F Smith; Sharon R Lewis
Journal:  Cochrane Database Syst Rev       Date:  2014-03-17

Review 5.  Pulse Oximetry for Monitoring Patients with COVID-19 at Home. Potential Pitfalls and Practical Guidance.

Authors:  Andrew M Luks; Erik R Swenson
Journal:  Ann Am Thorac Soc       Date:  2020-09

6.  Is pulse oximeter a reliable tool for non-critically ill patients with COVID-19?

Authors:  Aslıhan Gürün Kaya; Miraç Öz; İrem Akdemir Kalkan; Ezgi Gülten; Güle Çınar; Alpay Azap; Akın Kaya
Journal:  Int J Clin Pract       Date:  2021-10-21       Impact factor: 3.149

7.  Postoperative Hypoxemia Is Common and Persistent: A Prospective Blinded Observational Study.

Authors:  Zhuo Sun; Daniel I Sessler; Jarrod E Dalton; P J Devereaux; Aram Shahinyan; Amanda J Naylor; Matthew T Hutcherson; Patrick S Finnegan; Vikas Tandon; Saeed Darvish-Kazem; Shaan Chugh; Hussain Alzayer; Andrea Kurz
Journal:  Anesth Analg       Date:  2015-09       Impact factor: 6.627

8.  Do changes in pulse oximeter oxygen saturation predict equivalent changes in arterial oxygen saturation?

Authors:  Gavin D Perkins; Daniel F McAuley; Simon Giles; Helen Routledge; Fang Gao
Journal:  Crit Care       Date:  2003-06-11       Impact factor: 9.097

Review 9.  Pulse oximetry: fundamentals and technology update.

Authors:  Meir Nitzan; Ayal Romem; Robert Koppel
Journal:  Med Devices (Auckl)       Date:  2014-07-08

10.  Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes.

Authors:  Sohila Seifi; Alireza Khatony; Gholamreza Moradi; Alireza Abdi; Farid Najafi
Journal:  BMC Nurs       Date:  2018-04-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.