Literature DB >> 3553251

Correction of spatial distortion in MR imaging: a prerequisite for accurate stereotaxy.

L Schad, S Lott, F Schmitt, V Sturm, W J Lorenz.   

Abstract

With magnetic resonance (MR) imaging, accurate spatial information--critical for effective stereotaxy--demands a homogeneous static field and linear gradients. Inhomogeneities and nonlinearities induced by eddy currents during the pulse sequences distort the images and produce spurious displacements of the stereotactic coordinates in both the x-y plane and the z axis. These errors in position can be assessed by means of two phantoms placed within the stereotactic guidance system--a "two-dimensional phantom" displaying "pincushion" distortion in the image (i.e., x, y) plane, and the "three-dimensional phantom" displaying displacement, warp, and tilt of the image plane itself. The pincushion distortion can be "corrected" (reducing displacements from 5 to 1-2 mm) by calculations based on modeling the distortion as a fourth order two-dimensional polynomial. Based on these corrected images, errors in the z coordinate and tilt of image planes may be corrected by adjustment of the gradient shimming currents. Such correction not only implements stereotaxy under MR guidance but also provides for the accurate transfer of anatomic/pathologic information between MR and CT images.

Mesh:

Year:  1987        PMID: 3553251     DOI: 10.1097/00004728-198705000-00025

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  8 in total

1.  [Possibilities of an open magnetic resonance scanner integration in therapy simulation and three-dimensional radiotherapy planning].

Authors:  K Schubert; F Wenz; R Krempien; O Schramm; G Sroka-Perez; P Schraube; M Wannenmacher
Journal:  Strahlenther Onkol       Date:  1999-05       Impact factor: 3.621

2.  Titanium Riechert head ring for MR stereotaxy. Technical note.

Authors:  C B Ostertag; L R Schad; R Koch; R Maier; B Wowra
Journal:  Acta Neurochir (Wien)       Date:  1993       Impact factor: 2.216

Review 3.  New trends in head and neck imaging.

Authors:  R Mösges
Journal:  Eur Arch Otorhinolaryngol       Date:  1993       Impact factor: 2.503

4.  A survey of different high resolution visualization modes of a volumetric object with applications.

Authors:  J L Stievenart; E A Cabanis; P Menard; J Knoplioch; A Lopez; J Tamraz; M T Iba-Zizen; B Philippe; G Prevost; J C Bertrand
Journal:  Surg Radiol Anat       Date:  1993       Impact factor: 1.246

Review 5.  Neuronavigation and surgery of intracerebral tumours.

Authors:  P W A Willems; J W Berkelbach van der Sprenkel; C A F Tulleken; M A Viergever; M J B Taphoorn
Journal:  J Neurol       Date:  2006-09-20       Impact factor: 4.849

6.  Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI.

Authors:  L R Schad; M Bock; K Baudendistel; M Essig; J Debus; M V Knopp; R Engenhart; W J Lorenz
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

7.  A modular phantom and software to characterize 3D geometric distortion in MRI.

Authors:  Jordan M Slagowski; Yao Ding; Manik Aima; Zhifei Wen; Clifton D Fuller; Caroline Chung; J Matthew Debnam; Ken-Pin Hwang; Mo Kadbi; Janio Szklaruk; Jihong Wang
Journal:  Phys Med Biol       Date:  2020-09-28       Impact factor: 3.609

8.  An image fusion study of the geometric accuracy of magnetic resonance imaging with the Leksell stereotactic localization system.

Authors:  C Yu; Z Petrovich; M L Apuzzo; G Luxton
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

  8 in total