Literature DB >> 8475813

Titanium Riechert head ring for MR stereotaxy. Technical note.

C B Ostertag1, L R Schad, R Koch, R Maier, B Wowra.   

Abstract

Magnetic Resonance has become the preferred neuro-imaging modality. To fully take advantage of the high anatomical resolution the Riechert stereotactic system was adapted for use in Magnetic Resonance Stereotaxy. The head ring which until recently was made of an aluminum alloy has been replaced by an unsegmented head ring of pure titanium without changing the dimensions and fixation mode. No significant misregistration due to eddy currents has been noticed. Minor distortion induced by the titanium head ring can be corrected mathematically. Thus the geometric information is limited only by the pixel resolution of the MR image.

Entities:  

Mesh:

Year:  1993        PMID: 8475813     DOI: 10.1007/bf01405188

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  7 in total

1.  Correction of spatial distortion in magnetic resonance angiography for radiosurgical treatment planning of cerebral arteriovenous malformations.

Authors:  L R Schad; H H Ehricke; B Wowra; G Layer; R Engenhart; H U Kauczor; H J Zabel; G Brix; W J Lorenz
Journal:  Magn Reson Imaging       Date:  1992       Impact factor: 2.546

2.  A comparison between magnetic resonance imaging and computed tomography for stereotactic coordinate determination.

Authors:  D Kondziolka; P K Dempsey; L D Lunsford; J R Kestle; E J Dolan; E Kanal; R R Tasker
Journal:  Neurosurgery       Date:  1992-03       Impact factor: 4.654

3.  [A new stereotactic instrument for intracranial placement of electrodes].

Authors:  T RIECHERT; M WOLFF
Journal:  Arch Psychiatr Nervenkr Z Gesamte Neurol Psychiatr       Date:  1951

4.  New head fixation for the Riechert stereotaxic system. Technical note.

Authors:  C B Ostertag
Journal:  Acta Neurochir (Wien)       Date:  1988       Impact factor: 2.216

5.  Stereotaxic surgery with a magnetic resonance- and computerized tomography-compatible system.

Authors:  L D Lunsford; A J Martinez; R E Latchaw
Journal:  J Neurosurg       Date:  1986-06       Impact factor: 5.115

6.  Correction of spatial distortion in MR imaging: a prerequisite for accurate stereotaxy.

Authors:  L Schad; S Lott; F Schmitt; V Sturm; W J Lorenz
Journal:  J Comput Assist Tomogr       Date:  1987 May-Jun       Impact factor: 1.826

7.  Accuracy of area measurements made from MR images compared with computed tomography.

Authors:  X P Zhu; D R Checkley; D S Hickey; I Isherwood
Journal:  J Comput Assist Tomogr       Date:  1986 Jan-Feb       Impact factor: 1.826

  7 in total
  1 in total

Review 1.  Current concepts in stereotactic radiosurgery - a neurosurgical and radiooncological point of view.

Authors:  Jan Vesper; B Bölke; C Wille; P A Gerber; C Matuschek; M Peiper; H J Steiger; W Budach; G Lammering
Journal:  Eur J Med Res       Date:  2009-03-17       Impact factor: 2.175

  1 in total