| Literature DB >> 35475213 |
Ahmad Almujalhem1, Koon Ho Rha2.
Abstract
Introduction: The coming decade will see the emergence of many surgical robotic systems that need to prove their cost-effectiveness and clinical usability to gain the trust of robotic surgeons worldwide. Herein, we provide a concise review of the currently available robotic systems. Since the da Vinci Surgical System's patent expired and its market monopoly ended, many robotic surgical systems have, and will continue to, enter the market. Central to this is the challenge of gaining the trust of robotic surgeons in a cost-effective manner. However, the cumulative robotic surgical experience of Intuitive Surgical over these years-which has proven itself clinically and technically-is a great challenge for new surgical robots.Entities:
Year: 2020 PMID: 35475213 PMCID: PMC8988814 DOI: 10.1002/bco2.31
Source DB: PubMed Journal: BJUI Compass ISSN: 2688-4526
Robotic surgical systems summary
| Robot | Uses | Port | Robot Cart | Arm | Console | Controller | Enhanced imaging | Vision | Haptic feedback | Eye tracking | Instrument | Arm DOF | Instrument DOF | Cost (Million $) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DV Xi | MIS | MP | Single | 4 | Close | Joystick | FireFly | 3D HD | No | No | 10 uses | 3 | 7 | 1–1.5 |
| DV SP | MIS | SP | Single | 1 | Close | Joystick | FireFly | 3D HD | No | No | 10 uses | Rotational | Flexible | 2 |
| NOTES | ||||||||||||||
| LESS | ||||||||||||||
| Senhance | MIS | MP | Multiple | 4 | Open | Joystick | NOVADAQ | 3D HD | Yes | Yes | Unlimited | 3 | 7 | 1.3 |
| PINPOINT | ||||||||||||||
| Revo‐i | MIS | MP | Single | 4 | Close | Joystick | No | 3D HD | Yes | No | 20 uses | 3 | 7 | NA |
| Micro Hand S | MIS | MP | Single | 4 | Close | Joystick | No | 3D HD | No | No | NA | 3 | 7 | NA |
| SPORT | MIS | SP | Single | 1 | Open | Hand‐controller | No | 3D HD | NA | NA | NA | Rotational | Flexible | NA |
| NOTES | ||||||||||||||
| LESS | ||||||||||||||
| Versius | MIS | MP | Multiple | 4 | Open | Joystick | No | 3D HD | NA | NA | NA | 3 | 7 | Managed‐service contract system |
| MiroSurge | MIS | MP | Multiple | 3 | Open | Joystick | No | 3D HD | Yes | NA | NA | 3 | 7 | NA |
| Table‐mounted | ||||||||||||||
| Bitrack | MIS | MP | Single | 3 | Open | Joystick | No | 3D HD | NA | NA | NA | 3 | 7 | NA |
| Medicaroid | MIS | MP | Single | 4 | Open | Joystick | No | 3D HD | NA | NA | NA | 3 | 7 | NA |
| Verb | MIS | MP | Single | 4 | Open | Joystick | NA | 3D HD | NA | NA | NA | NA | NA | NA |
| SurgiBot | LESS | SP | Single | 1 | No console | Laparoscopic | NA | 3D HD | NAP | NAP | NA | Rotational | Flexible | NA |
| Handle | ||||||||||||||
| PROCEPT | NOTES | NAP | Single | 1 | No console | NAP | Real‐time US | HD | NAP | NAP | NA | NAP | NAP | NA |
| EMARO | MIS | SP | Single | 1 | No console | Pneumatic | NAP | HD | NAP | NAP | NA | Rotational | NAP | NA |
| Gyroscope | ||||||||||||||
| Roboflex | NOTES | NAP | Single | 1 | Open | Joystick | NAP | HD | NA | NAP | NAP | Rotational | Flexible | NA |
DOF, degree of freedom; DV, da Vinci; LESS, laparoendoscopic single port surgery; MP, multi‐port; NA, no available data; NAP, not applicable; NOTES, natural orifice transluminal endoscopic surgery; SP, single port.
FIGURE 1Robotic growth over surgical specialties
FIGURE 2SP da Vinci robot
FIGURE 3Revo‐I robot , ,
FIGURE 4Micro Hand S robot
FIGURE 5EMARO robot ,