Literature DB >> 19879615

Robotic thyroid surgery using a gasless, transaxillary approach and the da Vinci S system: the operative outcomes of 338 consecutive patients.

Sang-Wook Kang1, Seung Chul Lee, So Hee Lee, Kang Young Lee, Jong Ju Jeong, Yong Sang Lee, Kee-Hyun Nam, Hang Seok Chang, Woong Youn Chung, Cheong Soo Park.   

Abstract

BACKGROUND: Recently, robotic technology in the surgical area has gained wide popularity. However, in the filed of head and neck surgery, the applications of robotic instruments are problematic owing to spatial and technical limitations. The authors performed robot-assisted endoscopic thyroid operations in consecutive thyroid tumor patients using the newly introduced da Vinci S surgical system. Herein the authors describe the technique used and its utility for the operative management of thyroid tumors.
METHODS: From October 2007 to November 2008, 338 patients underwent robot-assisted endoscopic thyroid operations using a gasless, transaxillary approach. All procedures were successfully completed without conversion to an open procedure. Patient's clinicopathologic characteristics, operation types, operation times, the learning curve, and postoperative hospital stays and complications were evaluated.
RESULTS: The mean patient age was 40 years (range, 16-69) and the male to female ratio was 1:16.8. Two hundred and thirty-four patients underwent less than total and 104 underwent bilateral total thyroidectomy. Ipsilateral central compartment node dissection was conducted in all malignant cases. Mean operation time was 144.0 minutes (range, 69-347) and mean postoperative hospital stay was 3.3 days (range, 2-7). No serious postoperative complication occurred; there were 3 cases of recurrent laryngeal nerve injury and 1 of Horner's syndrome.
CONCLUSION: Our technique of robotic thyroid surgery using a gasless, transaxillary approach is feasible and safe in selected patients with a benign or malignant thyroid tumor.

Entities:  

Mesh:

Year:  2009        PMID: 19879615     DOI: 10.1016/j.surg.2009.09.007

Source DB:  PubMed          Journal:  Surgery        ISSN: 0039-6060            Impact factor:   3.982


  116 in total

1.  Robotic transaxillary endocrine surgery: a comparison with conventional open technique.

Authors:  Christina S Foley; Orhan Agcaoglu; Allan E Siperstein; Eren Berber
Journal:  Surg Endosc       Date:  2012-02-07       Impact factor: 4.584

2.  A comparative study of the surgical outcomes of robotic and conventional open modified radical neck dissection for papillary thyroid carcinoma with lateral neck node metastasis.

Authors:  Sang-Wook Kang; So Hee Lee; Jae Hyun Park; Jun Soo Jeong; Seulkee Park; Cho Rok Lee; Jong Ju Jeong; Kee-Hyun Nam; Woong Youn Chung; Cheong Soo Park
Journal:  Surg Endosc       Date:  2012-05-31       Impact factor: 4.584

Review 3.  Extracervical approaches to endoscopic thyroid surgery.

Authors:  Giorgos Papaspyrou; Alfio Ferlito; Carl E Silver; Jochen A Werner; Eric Genden; Andreas M Sesterhenn
Journal:  Surg Endosc       Date:  2010-09-16       Impact factor: 4.584

4.  Robotic thyroidectomy by a gasless unilateral axillo-breast or axillary approach: our early experiences.

Authors:  Kyung Tae; Yong Bae Ji; Jin Hyeok Jeong; Seung Hwan Lee; Mi Ae Jeong; Chul Won Park
Journal:  Surg Endosc       Date:  2010-06-22       Impact factor: 4.584

5.  Comparison of conventional thyroidectomy and endoscopic thyroidectomy via axillo-bilateral breast approach in papillary thyroid carcinoma patients.

Authors:  Seon Kwang Kim; Sang Yull Kang; Hyun Jo Youn; Sung Hoo Jung
Journal:  Surg Endosc       Date:  2015-10-28       Impact factor: 4.584

6.  Continuous Vagal Nerve Monitoring: Too Much of a Good Thing?

Authors:  David J Terris
Journal:  World J Surg       Date:  2016-03       Impact factor: 3.352

7.  Modifications of transaxillary approach in endoscopic da Vinci-assisted thyroid and parathyroid gland surgery.

Authors:  Basel Al Kadah; Micaela Piccoli; Barbara Mullineris; Giovanni Colli; Martin Janssen; Stephan Siemer; Bernhard Schick
Journal:  J Robot Surg       Date:  2014-09-02

8.  Load evaluation of the da Vinci surgical system for transoral robotic surgery.

Authors:  Kazunori Fujiwara; Takahiro Fukuhara; Koji Niimi; Takahiro Sato; Hiroya Kitano
Journal:  J Robot Surg       Date:  2015-10-17

9.  Endoscope-assisted facelift thyroid surgery: an initial experience using a new endoscopic technique.

Authors:  Jun-Ook Park; Sang-Yeon Kim; Byung-Joon Chun; Young-Hoon Joo; Kwang-Jae Cho; Young Hak Park; Min-Sik Kim; Dong-Il Sun
Journal:  Surg Endosc       Date:  2014-08-27       Impact factor: 4.584

10.  Early outcomes in transoral vestibular thyroidectomy: Robotic versus endoscopic techniques.

Authors:  Christopher R Razavi; Mai G Al Khadem; Akeweh Fondong; James H Clark; Jeremy D Richmon; Ralph P Tufano; Jonathon O Russell
Journal:  Head Neck       Date:  2018-05-13       Impact factor: 3.147

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.