| Literature DB >> 35435614 |
Shabnam Saadat1, Diana Perriman2, Jennie M Scarvell3, Paul N Smith4, Catherine R Galvin5, Joseph Lynch2, Mark R Pickering6.
Abstract
PURPOSE: The purpose of this paper is to present a method for registration of 3D computed tomography to 2D single-plane fluoroscopy knee images to provide 3D motion information for knee joints. This 3D kinematic information has unique utility for examining joint kinematics in conditions such as ligament injury, osteoarthritis and after joint replacement.Entities:
Keywords: Edge position difference; Image registration; Similarity measure; Sum-of-conditional variance; medical image analysis
Mesh:
Year: 2022 PMID: 35435614 PMCID: PMC9206621 DOI: 10.1007/s11548-022-02624-0
Source DB: PubMed Journal: Int J Comput Assist Radiol Surg ISSN: 1861-6410 Impact factor: 3.421
Fig. 1a, b show an example of 2D projection of a CT image and a fluoroscopy image to be registered. c Represents the binary edge image of the 2D projection of the CT image. The distance to the edge position of the fluoroscopy image is shown in d
Fig. 2Capturing a fluoroscopy frame from one of the knee cadavers
Mean error, standard deviation of error and mean absolute error of the proposed method for the relational kinematic parameters
| Relational kinematic parameters | The proposed method | ||
|---|---|---|---|
| Mean error | Standard deviation of error | Mean absolute error | |
| Flexion–extension (mm) | 0.1153 | 0.6985 | 0.6195 |
| Internal–external (mm) | 0.4151 | 0.3426 | |
| Abduction–adduction (mm) | 0.1622 | 0.6426 | 0.5750 |
| Medial–lateral ( | 0.5410 | 2.0432 | 1.7187 |
| Anterior–posterior ( | 1.0196 | 0.7254 | |
| Distraction–compression ( | 0.2533 | 0.1986 | 0.2690 |
Mean error, standard deviation of error and mean absolute error of the SCV method for the relational kinematic parameters, respectively
| Relational kinematic parameters | The SCV method | ||
|---|---|---|---|
| Mean error | Standard deviation of error | Mean absolute error | |
| Flexion–extension (mm) | 0.1427 | 0.6611 | 0.5839 |
| Internal–external (mm) | 0.4182 | 0.3438 | |
| Abduction–adduction (mm) | 0.1859 | 0.6134 | 0.5481 |
| Medial–lateral ( | 0.5375 | 2.0192 | 1.6864 |
| Anterior–posterior ( | 0.9909 | 0.6963 | |
| Distraction–compression ( | 0.2621 | 0.1955 | 0.2752 |
Fig. 3a, b and c show box plots of the error in relational rotation kinematic parameters per frame per cadaver obtained by the proposed and the SCV methods. d, e and f show box plots of the error in relational translation kinematic parameters obtained by the methods
Computation Time
| Method | Computation time (seconds) |
|---|---|
| The SCV method | 172.5 |
| The proposed method | 48.8 |