Literature DB >> 11055805

Image registration by maximization of combined mutual information and gradient information.

J P Pluim1, J B Maintz, M A Viergever.   

Abstract

Mutual information has developed into an accurate measure for rigid and affine monomodality and multimodality image registration. The robustness of the measure is questionable, however. A possible reason for this is the absence of spatial information in the measure. The present paper proposes to include spatial information by combining mutual information with a term based on the image gradient of the images to be registered. The gradient term not only seeks to align locations of high gradient magnitude, but also aims for a similar orientation of the gradients at these locations. Results of combining both standard mutual information as well as a normalized measure are presented for rigid registration of three-dimensional clinical images [magnetic resonance (MR), computed tomography (CT), and positron emission tomography (PET)]. The results indicate that the combined measures yield a better registration function does mutual information or normalized mutual information per se. The registration functions are less sensitive to low sampling resolution, do not contain incorrect global maxima that are sometimes found in the mutual information function, and interpolation-induced local minima can be reduced. These characteristics yield the promise of more robust registration measures. The accuracy of the combined measures is similar to that of mutual information-based methods.

Entities:  

Mesh:

Year:  2000        PMID: 11055805     DOI: 10.1109/42.876307

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  57 in total

1.  Rigid registration of medical images using 1D and 2D binary projections.

Authors:  Panayiotis Kotsas; Tony Dodd
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

2.  Automatic method to assess local CT-MR imaging registration accuracy on images of the head.

Authors:  Ion P I Pappas; Martin Styner; Puja Malik; Luca Remonda; Marco Caversaccio
Journal:  AJNR Am J Neuroradiol       Date:  2005-01       Impact factor: 3.825

3.  Retrospective distortion correction for 3D MR diffusion tensor microscopy using mutual information and Fourier deformations.

Authors:  Nilesh N Mistry; Edward W Hsu
Journal:  Magn Reson Med       Date:  2006-08       Impact factor: 4.668

4.  A multistage registration method using texture features.

Authors:  Andreja Jarc; Janez Pers; Stanislav Kovacic
Journal:  J Digit Imaging       Date:  2009-01-29       Impact factor: 4.056

5.  Vessel diameter measurement from intravital microscopy.

Authors:  Jaesung Lee; Artit C Jirapatnakul; Anthony P Reeves; William E Crowe; Ingrid H Sarelius
Journal:  Ann Biomed Eng       Date:  2009-03-11       Impact factor: 3.934

6.  Estimating nonrigid motion from inconsistent intensity with robust shape features.

Authors:  Wenyang Liu; Dan Ruan
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

Review 7.  Deformable medical image registration: a survey.

Authors:  Aristeidis Sotiras; Christos Davatzikos; Nikos Paragios
Journal:  IEEE Trans Med Imaging       Date:  2013-05-31       Impact factor: 10.048

8.  Elastic registration of multimodal prostate MRI and histology via multiattribute combined mutual information.

Authors:  Jonathan Chappelow; B Nicolas Bloch; Neil Rofsky; Elizabeth Genega; Robert Lenkinski; William DeWolf; Anant Madabhushi
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

9.  3D dental image registration using exhaustive deformable models: a comparative study.

Authors:  Maria-Pavlina Kalla; Theodore L Economopoulos; George K Matsopoulos
Journal:  Dentomaxillofac Radiol       Date:  2017-05-24       Impact factor: 2.419

10.  Wavelet-based image registration and segmentation framework for the quantitative evaluation of hydrocephalus.

Authors:  Fan Luo; Jeanette W Evans; Norma C Linney; Matthias H Schmidt; Peter H Gregson
Journal:  Int J Biomed Imaging       Date:  2010-04-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.