| Literature DB >> 35409860 |
Sanja Kezic1, Roberto Nunez1, Željka Babić2, Sarah Hallmann3, Martin S Havmose4, Jeanne D Johansen4, Swen M John5,6, Marija Macan2, Cara Symanzik5,6, Wolfgang Uter3, Patricia Weinert6, Rajka Turk2, Jelena Macan2, Henk F van der Molen1.
Abstract
INTRODUCTION: Exposure to hazardous chemicals released during hairdressing activities from hair care products puts hairdressers at risk of adverse health effects. Safety assessments of hair products are mainly focused on consumers, but exposure for professional hairdressers might be substantially higher.Entities:
Keywords: airborne exposure; hair salons; hairdressers; health effects; indoor exposure; inhalation
Mesh:
Substances:
Year: 2022 PMID: 35409860 PMCID: PMC8998463 DOI: 10.3390/ijerph19074176
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 3.390
Figure 1PRISMA Flow diagram for the screening and selection of articles.
Summary of studies investigating formaldehyde air concentrations (n = 8).
| 1st Author, Year of Publication | Workplace/Country | Number of Workplaces/Total Number of Workers | Exposure Measurement Conditions | Ventilation System | Air Concentrations |
|---|---|---|---|---|---|
|
| |||||
| Asare-Donkor, 2020 | beauty salons/Ghana | 60 salons/not reported | environmental samplers located at central area of the salon; sampling time 30 min | windows and ceiling fan | 130.53 ± 81.10 |
| Chang, 2018 | hairdressing salons/Taiwan | 5 salons/42 workers present during sampling of total 60 workers | environmental sampling; sampling time 5 h at a height of 1.3 m above the floor at various areas in the salon | 80% of the salons air conditioner, 20% air conditioner plus heat-recovery | 338 |
| Hadei, 2018 | beauty salons/Iran | 20 salons/184 active cosmetologists | environmental sampling for 3 × 30 min at a height of 1.5 m in the working areas | 60% fan, 30% fan plus open window, 10% air purifier | 11.88 ± 5.89 |
| Labreche, 2003 | hairdressing salons/Canada | 26 salons/not reported | personal and environmental sampling; sampling time from 15 min to 8 h during the busiest days | 42% natural ventilation (windows only); 58% general mechanical ventilation | all personal and environmental sampling |
| Peteffi, 2015 | beauty salons/Brazil | 6 salons/50 workers | environmental samplers placed within the workers’ respiration zone; sampling time 8 h | not reported | median 127.5 ** |
| Aglan, 2018 | hairdressing salons/Egypt | not reported/29 short term employed hairdressers (<5 years) | personal sampling; sampling time 15 min during the second step of the hair straightening procedure | not reported | ** 2060.3 ± 331.1 |
| not reported/31 long term employed hairdressers (>5 years) | environmental sampling; sampling time 15 min during the second step of the hair straightening procedure | not reported | ** 2244.3 ± 196.2 | ||
| Barbosa, 2019 | beauty salons/Brazil | 10 salons/8 low-exposed hairdressers | personal sampling; sampling time 8 h | not reported | median 15.94 ** |
| 10 salons/15 medium-exposed hairdressers | median 42.92 ** | ||||
| 10 salons/26 high-exposed hairdressers | median 85.85 ** | ||||
| Pexe, 2019 | beauty salons/Brazil | 23 salons/not reported | personal sampling for 15 min during hair straightening; | windows and doors opening, reported use of fans in 2 of 23 salons | ** 1672.8 ± 1280.3 |
SD = standard deviation; IQR = interquartile range. * unless otherwise indicated; ** concentrations reported in ppm were calculated in µg/m3 as given in the methods section.
Summary of studies reporting ammonia air concentrations (n = 5).
| 1st Author, Year of Publication | Workplace/Country | Number of Workplaces/Total Number of Workers | Exposure Measurement Conditions | Ventilation System | Air Concentrations |
|---|---|---|---|---|---|
| Mendes, 2011 | hairdressing salons/Portugal | 50 salons/not reported | environmental sampling; sampling time 30 min; | 62% open windows, 20% mechanical | ** 1598.4 ± 1528.9 |
| Mounier-Geyssant, 2006 | hairdressing salons/France | not reported/53 hairdressing apprentices | environmental sampling; samplers placed in the area where customers sit during and after applying permanent waving, hair colouring or bleaching, near the hair wash area and in the technical room where chemical mixtures are prepared; sampling time 5–8 h | two-thirds of customer spaces and one-third of technical spaces had a ventilation device (fan, air conditioning or other types of venting, | 680 ± 420 |
| personal sampling; sampling time 5–8 h | 900 ± 760 | ||||
| Nemer, 2015 | hairdressing salons/Palestine | 13 salons/2 to 10 hairdressers per salon | personal sampling; sampling duration from 45 to 305 min | 6 of 13 salons had no windows (three of which had air conditioning), two had only holes in the wall allowing for fresh air ventilation, remaining five of 13 salons had one window | 12,310 (0–202,100) |
| Oikawa, 2012 | beauty salons/Japan | 1 salon/5 hairdressers | environmental sampling; samplers placed close to hair treatment stations during perm treatment; sampling time 1 h, 3–4 times per day | mechanical ventilation | 484 ± 243 |
| Ronda, 2009 | hairdressing salons/Spain | 10 salons/2 to 7 hairdressers per salon | environmental sampling; | none of the salons had any general | 1800 |
SD = standard deviation; IQR = interquartile range. * unless otherwise indicated; ** concentrations reported in ppm were calculated in µg/m3 as given in the methods section.
Summary of studies reporting air concentrations of organic solvents: total volatile organic compounds (TVOC) (n = 5), toluene (n = 4), xylene (isomers) (n = 5), acetone (n = 3), benzene (n = 3), ethanol (n = 3), isopropanol (n = 3), ethylacetate (n = 3), and ethyl benzene (n = 3).
| 1st Author, Year of Publication | Workplace/Country | Number of Workplaces/Total Number of Workers | Exposure Measurement Conditions | Ventilation System | Air Concentrations |
|---|---|---|---|---|---|
|
| |||||
| De Gennaro, 2014 | hairdressing salons/Italy | 12 salons/average of 2 hairdressers per salon | environmental sampling; samplers placed in such way to avoid any direct emissions during working tasks; sampling time 24 h (working week days) | Air conditioning | 911.1 ± 770.0 |
| Mendes, 2011 | hairdressing salons/Portugal | 50 salons/134 hairdressers | environmental samplers were placed at least 0.6 m above the floor, below the ceiling and away from windows and doors, in rinsing, drying and technical areas; sampling time 45 min | 62% open windows, 20% mechanical ventilation, 62% air conditioning | 1400 ± 1200 |
| Moda, 2019 | hairdressing salons/UK | 5 salons/average of 2 hairdressers per salon | environmental sampling; at 1 m above the floor; | not reported | ** 8909.7 ± 15,580 |
| Ronda, 2009 | hairdressing salons/Spain | 10 salons/not reported, max. 2–7 hairdressers at work in individual salons (28 environmental measurements and 56 personal) | environmental sampling; sampler placed in mixing area; sampling time 3 h, 2 times per day | None of the salons had any general | 76,000 (38,000–250,000) |
| personal sampling; in the breathing zone of the working hairdressers | 107,000 | ||||
| Ma, 2010 | hairdressing salons/Taiwan | 62 salons/not reported | personal sampling; sampling time 12 h on working days | Not reported | ** 308.0 ± 193.0 |
|
| |||||
| Hadei, 2018 | hairdressing salons/Iran | 20 salons/not reported | environmental sampling for 3 × 30 min at a height of 1.5 m in the working areas | 60% fan, 30% fan plus open window, 10% air purifier | 9.18 ± 3.03 |
| Labreche, 2003 | hairdressing salons/Canada | 26 salons/not reported | personal and environmental sampling; sampling time 15 min to 8 h, during the busiest days | 42% natural ventilation (windows only)/58% general mechanical ventilation | 270 (20–1660) personal |
| Moradi, 2019 | beauty salons/Iran | 36 salons/36 beauty practitioners | environmental sampling for 30 min at a height of 1.5 m in the working areas | not reported | median 98.5 |
| Ronda, 2009 | hairdressing salons/Spain | 10 salons/not reported | personal sampling in the breathing zone of working hairdressers | none of the salons had any general | 300 (10–3990) personal |
|
| |||||
| Moradi, 2019 | beauty salons/Iran | 36 salons/36 beauty practitioners | environmental sampling for 30 min at a height of 1.5 m in the working areas. | median 16.6 | |
| Hadei, 2018 | hairdressing salons/Iran | 20 salons/not reported | environmental sampling for 3 × 30 min at a height of 1.5 m | 60% fan, 30% fan plus open window, 10% air purifier | 11.23 ± 2.57 (7.62–17.23) |
| Ronda, 2009 | hairdressing salons/Spain | 10 salons/not reported | personal sampling in the breathing zone of working hairdressers or environmental sampling at a height of 1.5 m above the floor in the mixing area; sampling was performed over one week for periods of 3 h | none of the salons had any general | 20 (0–20) |
|
| |||||
| Ronda, 2009 | hairdressing salons/Spain | 10 salons/not reported | personal sampling in the breathing zone of working hairdressers or environmental sampling at a height of 1.5 m above the floor in the mixing area. | none of the salons had any general | 10 (0–90) |
|
| |||||
| Moradi, 2019 | beauty salons/Iran | 36 salons/36 beauty practitioners | environmental samples; sampling for 30 min at a height of 1.5 m in the working areas. | not reported | median 7.7 |
| Hadei, 2018 | hairdressing salons/Iran | 20 salons/not reported | environmental sampling for 3 × 30 min at a height of 1.5 m | 60% fan, 30% fan plus open window, 10% air purifier | 6.78 ± 1.92 |
| Ronda, 2009 | hairdressing salons/Spain | 10 salons/not reported | personal sampling in the breathing zone of working hairdressers or environmental sampling at a height of 1.5 m above the floor in the mixing area; sampling was performed over one week for periods of 3 h | none of the salons had any general | 10 (0–60) |
|
| |||||
| Hadei, 2018 | hairdressing salons/Iran | 20 salons/not reported | environmental sampling for 3 × 30 min at a height of 1.5 m | 60% fan, 30% fan plus open window, 10% air purifier | 7.54 ± 1.87 |
| Moradi, 2019 | beauty salons/Iran | 36 salons/36 beauty practitioners | environmental sampling for 30 min at a height of 1.5 m in the working areas. | not reported | median 4.3 |
| Ronda, 2009 | hairdressing salons/Spain | 10 salons/not reported | personal sampling in the breathing zone of working hairdressers or environmental sampling at a height of 1.5 m above the floor in the mixing area; sampling was performed over one week for periods of 3 h | none of the salons had any general | 10 (0–20) |
|
| |||||
| Hadei, 2018 | hairdressing salons/Iran | 20 salons/not reported | environmental sampling for 3 × 30 min at a height of 1.5 m in the working areas | 60% fan, 30% fan plus open window, 10% air purifier | 14.00 ± 4.21 |
| Moradi, 2019 | beauty salons/Iran | 36 salons/36 beauty practitioners | environmental sampling for 30 min at a height of 1.5 m in the working areas. | not reported | median 6.8 |
| Ronda, 2009 | hairdressing salons/Spain | 10 salons/not reported | personal sampling in the breathing zone of working hairdressers or environmental sampling at a height of 1.5 m above the floor in the mixing area; sampling was performed over one week for periods of 3 h | none of the salons had any general | 10 (0–50) |
|
| |||||
| Chang, 2018 | hairdressing salons/Taiwan | 5 salons/not reported | environmental sampling with a sampling time of 5 h at a height of 1.3 m above the floor at various areas in the salon | 80% of the salons air conditioner, 20% air conditioner plus heat-recovery | 1860 |
| Labreche, 2003 | hairdressing salons/Canada | 26 salons/not reported | personal and environmental; sampling time 15 min to 8 h during the busiest days | 42% natural ventilation (windows only)/58% general mechanical ventilation | 39,900 (170–447,170) personal |
| Ronda, 2009 | hairdressing salons/Spain | 10 salons/not reported | personal sampling in the breathing zone of working hairdressers or environmental sampling at a height of 1.5 m above the floor in the mixing area; sampling was performed over one week for periods of 3 h | None of the salons had any general | 2950 (0–43,120) personal |
|
| |||||
| Chang, 2018 | hairdressing salons/Taiwan | 5 salons/not reported | environmental sampling, with a sampling time of 5 h at a height of 1.3 m above the floor at various areas in the salon | 80% of the salons air conditioner, 20% air conditioner plus heat-recovery | 208 (14.5–1240) |
| Labreche, 2003 | hairdressing salons/Canada | 26 salons/not reported | personal and environmental; sampling time 15 min to 8 h during the busiest days | 42% natural ventilation (windows only)/58% general mechanical ventilation | 3130 (40–28,870) personal |
| Ronda, 2009 | hairdressing salons/Spain | 10 salons/not reported | personal sampling in the breathing zone of working hairdressers or environmental sampling at a height of 1.5 m above the floor in the mixing area; sampling was performed over one week for periods of 3 h | none of the salons had any general | 600 (10–2970) personal |
|
| |||||
| Chang, 2018 | hairdressing salons/Taiwan | 5 salons/not reported | environmental sampling, with a sampling time of 5 h at a height of 1.3 m above the floor at various areas in the salon | 80% of the salons air conditioner, 20% air conditioner plus heat-recovery | 77.9 (1.86–260) |
| Labreche, 2003 | hairdressing salons/Canada | 26 salons/not reported | personal and environmental; sampling time from 15 min to 8 h during the busiest days | 42% natural ventilation (windows only)/58% general mechanical ventilation | 3770 (810–22,240) personal |
| Ronda, 2009 | hairdressing salons/Spain | 10 salons/not reported | personal sampling in the breathing zone of working hairdressers or environmental sampling at a height of 1.5 m above the floor in the mixing area | none of the salons had any general | 310 (10–2320) personal |
|
| |||||
| Chang, 2018 | hairdressing salons/Taiwan | 5 salons/not reported | environmental sampling, with a sampling time of 5 h at a height of 1.3 m above the floor at various areas in the salon | 80% of the salons air conditioner, 20% air conditioner plus heat-recovery | 190 (0.3–1310) |
| Labreche, 2003 | hairdressing salons/Canada | 26 salons/not reported | personal and environmental; sampling time from 15 min to 8 h, during the busiest days | 42% natural ventilation (windows only)/58% general mechanical ventilation | 1340 (180–3440) personal |
| Ronda, 2009 | hairdressing salons/Spain | 10 salons/not reported | personal sampling in the breathing zone of working hairdressers or environmental sampling at a height of 1.5 m above the floor in the mixing area; sampling was performed over one week for periods of 3 h | none of the salons had any general | 1190 (0–14,740) personal |
* unless otherwise indicated; ** concentrations reported in ppm were calculated in µg/m3 as given in the methods section. SD = standard deviation; IQR = interquartile range.
Figure 2Air concentrations of formaldehyde, ammonia, TVOC, aromatic and aliphatic solvents obtained from personal and environmental samples. The letters by the symbols refer to reference numbers as follows: a [5]; b [6]; c [30]; d [31]; e [32]; f [33]; g [34]; h [35]; I [36]; j [37]; s [38]; k [39]; l [40]; m [41]; n [42]; o [43]; p [44]; r [45]. Data are presented as mean and ranges unless indicated otherwise. * Median and range. ** Mean of medians and range. OEL: occupational exposure limit.