Literature DB >> 16030526

Ammonia exposure and hazard assessment for selected household cleaning product uses.

Marion J Fedoruk1, Rod Bronstein, Brent D Kerger.   

Abstract

There is scant information pertaining to airborne ammonia exposures from either spills or common household uses of ammonia-containing floor and tile cleaners or from spray-on glass cleaners. We assessed instantaneous and event-specific time-weighted average (TWA) exposures to airborne ammonia during spills and use (per label directions) of a household floor and tile cleaner and two spray-on window cleaners. Airborne ammonia levels measured at breathing zone height (BZH) above the spilled floor and tile cleaner product reached 500 p.p.m. within 5 min, while levels for spilled window cleaner were below 8 p.p.m. TWA exposures were assessed while tile walls and floors were cleaned in three different bathrooms of a residence, and during use of a spray-on glass cleaner while washing several large windows in an office setting. NIOSH Method 6015 was utilized with concurrent field measurements every 60 s using a Drager PAC III monitor with an electrochemical cell detector. Peak ammonia levels ranged from 16 to 28 p.p.m. and short-term TWA concentrations ranged from 9.4 to 13 p.p.m. during mixing (0.1% ammonia) and cleaning tiles in the three bathrooms. Ammonia exposures while using spray-on window cleaner were over 10-fold lower (TWA=0.65 p.p.m.). Use of the floor and tile cleaner mixed at 0.2% ammonia led to peak airborne ammonia levels within 3-5 min at 36-90 p.p.m., and use of full strength cleaner (3% ammonia) led to peak ammonia levels of 125 to >200 p.p.m. within 2-3 min. Spillage or intentional use of the full strength floor and tile cleaner led to airborne ammonia concentrations that exceed occupational short-term exposure limits, while spillage or use of the spray-on window cleaner did not approach potentially hazardous airborne ammonia levels and likely represents a minimal inhalation health hazard. We conclude that routine household uses of ammonia are unlikely to produce significant exposures when using standard cleaning solutions (0.1-0.2%), but spillage or use of concentrated ammonia solutions (e.g., 3%) in poorly ventilated areas can lead to potentially hazardous airborne ammonia exposures.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16030526     DOI: 10.1038/sj.jea.7500431

Source DB:  PubMed          Journal:  J Expo Anal Environ Epidemiol        ISSN: 1053-4245


  10 in total

1.  Reducing hazardous cleaning product use: a collaborative effort.

Authors:  Elise Pechter; Lenore S Azaroff; Isabel López; Marcy Goldstein-Gelb
Journal:  Public Health Rep       Date:  2009 Jul-Aug       Impact factor: 2.792

2.  Quantitative assessment of airborne exposures generated during common cleaning tasks: a pilot study.

Authors:  Anila Bello; Margaret M Quinn; Melissa J Perry; Donald K Milton
Journal:  Environ Health       Date:  2010-11-30       Impact factor: 5.984

3.  Effect of exposure to detergents and other chemicals on biomarkers of pulmonary response in exhaled breath from hospital cleaners: a pilot study.

Authors:  Massimo Corradi; Petra Gergelova; Elisabetta Di Pilato; Giuseppina Folesani; Matteo Goldoni; Roberta Andreoli; Luisella Selis; Antonio Mutti
Journal:  Int Arch Occup Environ Health       Date:  2011-07-22       Impact factor: 3.015

4.  Torsional wave elastography to assess the mechanical properties of the cornea.

Authors:  Jorge Torres; Inas H Faris; Antonio Callejas; Felisa Reyes-Ortega; Juan Melchor; Miguel Gonzalez-Andrades; Guillermo Rus
Journal:  Sci Rep       Date:  2022-05-19       Impact factor: 4.996

5.  The use of household cleaning sprays and adult asthma: an international longitudinal study.

Authors:  Jan-Paul Zock; Estel Plana; Deborah Jarvis; Josep M Antó; Hans Kromhout; Susan M Kennedy; Nino Künzli; Simona Villani; Mario Olivieri; Kjell Torén; Katja Radon; Jordi Sunyer; Anna Dahlman-Hoglund; Dan Norbäck; Manolis Kogevinas
Journal:  Am J Respir Crit Care Med       Date:  2007-06-21       Impact factor: 21.405

6.  Highly sensitive polyaniline-coated fiber gas sensors for real-time monitoring of ammonia gas.

Authors:  Naraporn Indarit; Yong-Hoon Kim; Nattasamon Petchsang; Rawat Jaisutti
Journal:  RSC Adv       Date:  2019-08-27       Impact factor: 4.036

7.  Ultrahigh Selective Room-Temperature Ammonia Gas Sensor Based on Tin-Titanium Dioxide/reduced Graphene/Carbon Nanotube Nanocomposites by the Solvothermal Method.

Authors:  Yotsarayuth Seekaew; Weeraphat Pon-On; Chatchawal Wongchoosuk
Journal:  ACS Omega       Date:  2019-10-03

Review 8.  Peak Inhalation Exposure Metrics Used in Occupational Epidemiologic and Exposure Studies.

Authors:  M Abbas Virji; Laura Kurth
Journal:  Front Public Health       Date:  2021-01-08

Review 9.  Occupational Exposure of Hairdressers to Airborne Hazardous Chemicals: A Scoping Review.

Authors:  Sanja Kezic; Roberto Nunez; Željka Babić; Sarah Hallmann; Martin S Havmose; Jeanne D Johansen; Swen M John; Marija Macan; Cara Symanzik; Wolfgang Uter; Patricia Weinert; Rajka Turk; Jelena Macan; Henk F van der Molen
Journal:  Int J Environ Res Public Health       Date:  2022-03-31       Impact factor: 3.390

10.  Room-Temperature Ammonia Sensor Based on ZnO Nanorods Deposited on ST-Cut Quartz Surface Acoustic Wave Devices.

Authors:  Wei Li; Yuanjun Guo; Yongliang Tang; Xiaotao Zu; Jinyi Ma; Lu Wang; Yong Qing Fu
Journal:  Sensors (Basel)       Date:  2017-05-17       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.