Literature DB >> 35383946

Generative learning approach for radiation dose reduction in X-ray guided cardiac interventions.

Fariba Azizmohammadi1, Iñaki Navarro Castellanos2, Joaquim Miró2, Paul Segars3, Ehsan Samei3, Luc Duong1.   

Abstract

BACKGROUND: Navigation guidance in cardiac interventions is provided by X-ray angiography. Cumulative radiation exposure is a serious concern for pediatric cardiac interventions.
PURPOSE: A generative learning-based approach is proposed to predict X-ray angiography frames to reduce the radiation exposure for pediatric cardiac interventions while preserving the image quality.
METHODS: Frame predictions are based on a model-free motion estimation approach using a long short-term memory architecture and a content predictor using a convolutional neural network structure. The presented model thus estimates contrast-enhanced vascular structures such as the coronary arteries and their motion in X-ray sequences in an end-to-end system. This work was validated with 56 simulated and 52 patients' X-ray angiography sequences.
RESULTS: Using the predicted images can reduce the number of pulses by up to three new frames without affecting the image quality. The average required acquisition can drop by 30% per second for a 15 fps acquisition. The average structural similarity index measurement was 97% for the simulated dataset and 82% for the patients' dataset.
CONCLUSIONS: Frame prediction using a learning-based method is promising for minimizing radiation dose exposure. The required pulse rate is reduced while preserving the frame rate and the image quality. With proper integration in X-ray angiography systems, this method can pave the way for improved dose management.
© 2022 American Association of Physicists in Medicine.

Entities:  

Keywords:  X-ray angiography; cardiac interventions; radiation dose reduction

Mesh:

Year:  2022        PMID: 35383946      PMCID: PMC9547341          DOI: 10.1002/mp.15654

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.506


  19 in total

Review 1.  Fluoroscopy: patient radiation exposure issues.

Authors:  M Mahesh
Journal:  Radiographics       Date:  2001 Jul-Aug       Impact factor: 5.333

2.  Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT.

Authors:  Peter Hunold; Florian M Vogt; Axel Schmermund; Jörg F Debatin; Gert Kerkhoff; Thomas Budde; Raimund Erbel; Klaus Ewen; Jörg Barkhausen
Journal:  Radiology       Date:  2003-01       Impact factor: 11.105

3.  Radiation Exposure in Cardiac Catheterization: Operator Behavior Matters.

Authors:  Taisei Kobayashi; John W Hirshfeld
Journal:  Circ Cardiovasc Interv       Date:  2017-08       Impact factor: 6.546

4.  A retrospective study of radiation dose measurements comparing different cath lab X-ray systems in a sample population of patients undergoing percutaneous coronary intervention for chronic total occlusions.

Authors:  Andrew H McNeice; Matthew Brooks; Colm G Hanratty; Michael Stevenson; James C Spratt; Simon J Walsh
Journal:  Catheter Cardiovasc Interv       Date:  2018-02-07       Impact factor: 2.692

5.  Model-free Cardiorespiratory Motion Prediction from X-ray Angiography Sequence with LSTM Network.

Authors:  Fariba Azizmohammadi; Remi Martin; Joaquim Miro; Luc Duong
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2019-07

6.  Perceptual comparison of pulsed and continuous fluoroscopy.

Authors:  R Aufrichtig; P Xue; C W Thomas; G C Gilmore; D L Wilson
Journal:  Med Phys       Date:  1994-02       Impact factor: 4.071

7.  Reduction of Fluoroscopy Time and Radiation Dosage During Catheter Ablation for Atrial Fibrillation.

Authors:  Kenichiro Yamagata; Bashar Aldhoon; Josef Kautzner
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-08

8.  Impact of latest generation cardiac interventional X-ray equipment on patient image quality and radiation dose for trans-catheter aortic valve implantations.

Authors:  Amber J Gislason-Lee; Claire Keeble; Christoper J Malkin; Daniel Egleston; Josephine Bexon; Stephen M Kengyelics; Daniel Blackman; Andrew G Davies
Journal:  Br J Radiol       Date:  2016-09-29       Impact factor: 3.039

9.  Motion-flow-guided recurrent network for respiratory signal estimation of x-ray angiographic image sequences.

Authors:  Huihui Fang; Heng Li; Shuang Song; Kun Pang; Danni Ai; Jingfan Fan; Hong Song; Yang Yu; Jian Yang
Journal:  Phys Med Biol       Date:  2020-12-11       Impact factor: 3.609

10.  Global birth prevalence of congenital heart defects 1970-2017: updated systematic review and meta-analysis of 260 studies.

Authors:  Yingjuan Liu; Sen Chen; Liesl Zühlke; Graeme C Black; Mun-Kit Choy; Ningxiu Li; Bernard D Keavney
Journal:  Int J Epidemiol       Date:  2019-04-01       Impact factor: 7.196

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.