Literature DB >> 27617094

Reduction of Fluoroscopy Time and Radiation Dosage During Catheter Ablation for Atrial Fibrillation.

Kenichiro Yamagata1, Bashar Aldhoon1, Josef Kautzner1.   

Abstract

Radiofrequency catheter ablation has become the treatment of choice for atrial fibrillation (AF) that does not respond to antiarrhythmic drug therapy. During the procedure, fluoroscopy imaging is still considered essential to visualise catheters in real-time. However, radiation is often ignored by physicians since it is invisible and the long-term risks are underestimated. In this respect, it must be emphasised that radiation exposure has various potentially harmful effects, such as acute skin injury, malignancies and genetic disease, both to patients and physicians. For this reason, every electrophysiologist should be aware of the problem and should learn how to decrease radiation exposure by both changing the setting of the system and using complementary imaging technologies. In this review, we aim to discuss the basics of X-ray exposure and suggest practical instructions for how to reduce radiation dosage during AF ablation procedures.

Entities:  

Keywords:  Atrial fibrillation; fluoroscopy; imaging technology; radiation exposure; radiofrequency ablation

Year:  2016        PMID: 27617094      PMCID: PMC5013175          DOI: 10.15420/AER.2016.16.2

Source DB:  PubMed          Journal:  Arrhythm Electrophysiol Rev        ISSN: 2050-3369


  93 in total

Review 1.  Catheter ablation utilizing remote magnetic navigation: a review of applications and outcomes.

Authors:  Jason Bradfield; Roderick Tung; Ravi Mandapati; Noel G Boyle; Kalyanam Shivkumar
Journal:  Pacing Clin Electrophysiol       Date:  2012-04-17       Impact factor: 1.976

2.  Occupational exposure to ionizing radiation is associated with autoimmune thyroid disease.

Authors:  Henry Völzke; André Werner; Henri Wallaschofski; Nele Friedrich; Daniel M Robinson; Stefan Kindler; Matthias Kraft; Ulrich John; Wolfgang Hoffmann
Journal:  J Clin Endocrinol Metab       Date:  2005-05-10       Impact factor: 5.958

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

4.  Review of radiation safety in the cardiac catheterization laboratory.

Authors:  L W Johnson; R J Moore; S Balter
Journal:  Cathet Cardiovasc Diagn       Date:  1992-03

5.  Guidelines for patient radiation dose management.

Authors:  Michael S Stecker; Stephen Balter; Richard B Towbin; Donald L Miller; Eliseo Vañó; Gabriel Bartal; J Fritz Angle; Christine P Chao; Alan M Cohen; Robert G Dixon; Kathleen Gross; George G Hartnell; Beth Schueler; John D Statler; Thierry de Baère; John F Cardella
Journal:  J Vasc Interv Radiol       Date:  2009-07       Impact factor: 3.464

Review 6.  New technologies in atrial fibrillation ablation.

Authors:  J David Burkhardt; Andrea Natale
Journal:  Circulation       Date:  2009-10-13       Impact factor: 29.690

7.  Catheter ablation of atrial fibrillation without fluoroscopy using intracardiac echocardiography and electroanatomic mapping.

Authors:  John D Ferguson; Adam Helms; J Michael Mangrum; Srijoy Mahapatra; Pamela Mason; Ken Bilchick; George McDaniel; David Wiggins; John P DiMarco
Journal:  Circ Arrhythm Electrophysiol       Date:  2009-12

8.  Efficacy and safety of targeted focal ablation versus PV isolation assisted by magnetic electroanatomic mapping.

Authors:  Francis E Marchlinski; David Callans; Sanjay Dixit; Edward P Gerstenfeld; Robert Rho; Jian-Fang Ren; Erica Zado
Journal:  J Cardiovasc Electrophysiol       Date:  2003-04

Review 9.  Occupational radiation doses to operators performing cardiac catheterization procedures.

Authors:  Kwang Pyo Kim; Donald L Miller; Stephen Balter; Ruth A Kleinerman; Martha S Linet; Deukwoo Kwon; Steven L Simon
Journal:  Health Phys       Date:  2008-03       Impact factor: 1.316

10.  Reduced fluoroscopy during atrial fibrillation ablation: benefits of robotic guided navigation.

Authors:  Daniel Steven; Helge Servatius; Thomas Rostock; Boris Hoffmann; Imke Drewitz; Kai Müllerleile; Arian Sultan; Muhammet Ali Aydin; Thomas Meinertz; Stephan Willems
Journal:  J Cardiovasc Electrophysiol       Date:  2009-09-28
View more
  3 in total

1.  Implementation of a near-zero fluoroscopy approach in interventional electrophysiology: impact of operator experience.

Authors:  Severin Wannagat; Lena Loehr; Sebastian Lask; Katharina Völk; Tamer Karaköse; Cemil Özcelik; Andreas Mügge; Alexander Wutzler
Journal:  J Interv Card Electrophysiol       Date:  2018-02-19       Impact factor: 1.900

2.  Generative learning approach for radiation dose reduction in X-ray guided cardiac interventions.

Authors:  Fariba Azizmohammadi; Iñaki Navarro Castellanos; Joaquim Miró; Paul Segars; Ehsan Samei; Luc Duong
Journal:  Med Phys       Date:  2022-04-18       Impact factor: 4.506

3.  The use of intracardiac echocardiography catheters in endocardial ablation of cardiac arrhythmia: Meta-analysis of efficiency, effectiveness, and safety outcomes.

Authors:  Masahiko Goya; Diana Frame; Larry Gache; Yoko Ichishima; Daiane Oliveira Tayar; Laura Goldstein; Stephanie Hsiao Yu Lee
Journal:  J Cardiovasc Electrophysiol       Date:  2020-01-30
  3 in total