Andy Schumann1, Karl-Jürgen Bär2.
Abstract
Autonomic regulation of blood pressure and cardiac rhythm progressively declines with increasing age. Impaired cardiovascular control promotes a variety of age-related cardio-vascular conditions. This study aims to provide a database of high-resolution biological signals to describe the effect of healthy aging on cardiovascular regulation. Electrocardiogram and continuous non-invasive blood pressure signals were recorded simultaneously at rest in 1,121 healthy volunteers. With this database, we provide raw signals as well as basic demographic information such as gender and body mass index. To demonstrate validity of the acquired data, we present the well-known decline of heart rate variability with increasing age in this database.Entities:
Mesh:
Year: 2022 PMID: 35322044 PMCID: PMC8943176 DOI: 10.1038/s41597-022-01202-y
Source DB: PubMed Journal: Sci Data ISSN: 2052-4463 Impact factor: 6.444
Demographic information on the entire sample of healthy volunteers and divided into subgroups that have been recorded with one of the two measurement systems (TFM: CNSystems Task Force Monitor and BIOPAC MP150 with CNSystems CNAP 500).
| Parameter | Total (N = 1,121) | TFM (N = 621) | MP150 (N = 500) | |||
|---|---|---|---|---|---|---|
| Mean ± SD | Missing | Mean ± SD | Missing | Mean ± SD | Missing | |
| Age [years] | 32.5 ± 14.7 | 25 | 33.5 ± 15.7 | 24 | 31.3 ± 13.3 | 1 |
| Gender [f/m] | 670/433 | 2 | 383/243 | 0 | 287/190 | 2 |
| BMI [kg/m²] | 23.7 ± 4.5 | 0 | 23.9 ± 5.0 | 0 | 23.4 ± 3.6 | 0 |
BMI: body mass index. SD: standard deviation.
Fig. 1Cardiovascular recordings using system 1 - the Task Force Monitor (CNSystems), or system 2 – the CNAP 500 (CNSystems) combined with an MP150 acquisition unit (BIOPAC Systems Inc.). Top left: In System 1, four electrodes have been attached at the right arm (red), the left arm (yellow), the left abdomen (green), and the right abdomen (black). Two ECG channels have been recorded between the electrodes red and yellow (lead I), and between red and green (lead II). Pressure cuffs have been attached around the left arm as well as left middle and index finger. Top right: Two ECG leads were sampled synchronously at 1000 Hz and the continuous blood pressure signal at 100 Hz. Bottom left: In System 2, three electrodes have been attached below the centre of the right clavicle (white), at the left lower thorax (7th intracoastal space at midclavicular line) (red), and at the sternum (black). One ECG channel has been recorded between the electrodes red and white (lead II). Pressure cuffs were attached around the left arm as well as left middle and index finger. Bottom right: The ECG was sampled synchronously at 1000 Hz and the continuous blood pressure signal at 100 Hz. Pictures from www.cnsystems.com and www.biopac.com adapted with permission.
Fig. 2Age dependency of heart rate variability. (a) Standard deviation of heart beat intervals in age bins (SDNN). (b) Root mean square of successive differences between heart beat intervals in age bins (RMSSD). (c) Deceleration capacity of heart beat intervals in age bins (DC).
| Measurement(s) | Cardiovascular autonomic function |
| Technology Type(s) | Physiological signals |
| Sample Characteristic - Organism | Homo sapiens |