| Literature DB >> 35317731 |
Chandima Jeewandara1, Dinuka Guruge2, Pradeep Darshana Pushpakumara1, Deshan Madhusanka1, Tibutius Thanesh Jayadas1, Indika Prasad Chaturanga3, Inoka Sepali Aberathna1, Saubhagya Danasekara1, Thilagaraj Pathmanathan1, Deshni Jayathilaka1, Gayasha Somathilaka1, Heshan Kuruppu1, Laksiri Gomes1, Vitjith Gunasekara3, Ruwan Wijayamuni2, Graham S Ogg1,4, Gathsaurie Neelika Malavige5,6.
Abstract
BACKGROUND: SARS-CoV-2 rapid antigen (Ag) detection kits are widely used in addition to quantitative reverse transcription PCR PCR (RT-qPCR), as they are cheaper with a rapid turnaround time. As there are many concerns regarding their sensitivity and specificity, in different settings, we evaluated two WHO approved rapid Ag kits in a large cohort of Sri Lankan individuals.Entities:
Keywords: Abbott Ag test; Antibodies; PCR; Rapid antigen tests; SARS-CoV-2; SD-Biosensor Ag test
Mesh:
Substances:
Year: 2022 PMID: 35317731 PMCID: PMC8938642 DOI: 10.1186/s12879-022-07240-6
Source DB: PubMed Journal: BMC Infect Dis ISSN: 1471-2334 Impact factor: 3.090
Positivity rate of the SD-Biosensor rapid Ag kit for different RT-qPCR kits at different Ct values
| PCR Kit (number of PCR positive samples) | Avg Ct value for PCR | Number of samples used | Sensitivity of the SD-Biosensor Ag kit (%) | 95% CI lower limit (%) | 95% CI upper limit (%) |
|---|---|---|---|---|---|
| SeeGene Kit (n = 505) | < 25 | 177 | 76.6 | 69.5 | 82.5 |
| 26–30 | 130 | 36.2 | 28.1 | 45.1 | |
| 31–38 | 198 | 6.1 | 3.3 | 10.6 | |
| TAQPATH Kit (n = 186) | < 25 | 87 | 71.3 | 60.4 | 80.2 |
| 26–30 | 77 | 13 | 6.7 | 23 | |
| 31–38 | 22 | 9.5 | 1.7 | 31.8 | |
| SD-Biosensor RT-qPCR Kit (n = 183) | < 25 | 61 | 72.1 | 59% | 82.5 |
| 26–30 | 51 | 7.8 | 2.5% | 19.7 | |
| 31–38 | 71 | 0% | 0 | 6.4 |
Fig. 1Cycle threshold (Ct) values for different gene targets in different RT-qPCR kits compared to the results of the SD-Biosensor rapid Ag kit. The Ct values for the RdRP gene (A), S gene (B), N gene (C) and E gene (D) was compared for different kits for Ag positive and Ag negative samples. The lines indicate the median and the error bars the IQR
Positivity rate of the Abbott rapid Ag kit for different RT-qPCR kits at different Ct value
| PCR Kit (number of PCR positive samples) | Avg Ct value for PCR | Number of samples used | Sensitivity of the Abbott Ag kit (%) | 95% CI lower limit (%) | 95% CI upper limit (%) |
|---|---|---|---|---|---|
| SeeGene Kit (n = 53) | < 25 | 22 | 77.3 | 54.2 | 91.3 |
| 26–30 | 14 | 7.1 | 0.4 | 35.8 | |
| 31–38 | 17 | 0 | 0 | 22.9 | |
| TAQPATH Kit (n = 201) | < 25 | 118 | 81.4 | 72.9 | 87.7 |
| 26–30 | 75 | 18.7 | 10.9 | 29.7 | |
| 31–38 | 8 | 25 | 4.5 | 64.4 | |
| Hybri-Bio Kit (n = 32) | < 25 | 18 | 88.9 | 63.9 | 98.1 |
| 26–30 | 5 | 60 | 17 | 92.7 | |
| 31–38 | 9 | 11.1 | 0.6 | 49 |
Fig. 2Cycle threshold (Ct) values for different gene targets in different RT-qPCR kits compared to the results of the Abbott rapid Ag kit. The Ct values for the RdRP gene (A), S gene (B), N gene (C) and E gene (D) was compared for different kits for Ag positive and Ag negative samples. The lines indicate the median and the error bars the IQR
Fig. 3Comparison of the Ct values for different gene targets of RT-qPCR kits of positive samples from the SD-Biosensor Ag kit and the Abbott Ag kit. The Ct values for the RdRP gene (A), S gene (B), N gene (C) and E gene (D) was compared for different kits for SD-Biosensor Ag positive and Abbot Ag positive samples. The lines indicate the median and the error bars the IQR
The presence of SARS-CoV2 specific antibodies for different RT-qPCR kits and different Ct values
| Avg Ct values | Seegene | TAQPATH | SD-Biosensor |
|---|---|---|---|
| < 25 | 21/80 = 26.25% | 15/63 = 23.81% | 10/24 = 41.67% |
| 26–30 | 41/52 = 78.85% | 22/62 = 35.48% | 12/17 = 70.59% |
| 31–38 | 58/70 = 82.86% | 6/12 = 50% | 18/39 = 46.15% |
The presence of SARS-CoV2 specific antibodies, in those who were tested positive vs. negative for the SARS-CoV2 rapid antigen kits
| Ab Positive | Ab Negative | Total | |
|---|---|---|---|
| SD-Biosensor Ag Positive | 60 (32.1%) | 127 | 187 |
| SD-Biosensor Ag Negative | 432 (24.6%) | 1319 | 1751 |
| Abbott Ag Positive | 10 (26.3%) | 28 | 38 |
| Abbott Ag Negative | 109 (18.1%) | 493 | 602 |