| Literature DB >> 35284412 |
Ling Sun1,2, Xiaoyu Zhang1,2, Mi Tian1,2, Yang Shen1,2, Jing Zhao1,2, Xingtao Zhou1,2.
Abstract
Purpose: To investigate the safety and efficacy of topography-guided transepithelial accelerated corneal collagen cross-linking for low refractive error correction in patients with keratoconus.Entities:
Keywords: keratoconus; pilot study; refractive error; topography guided; transepithelial accelerated corneal collagen cross-linking
Year: 2022 PMID: 35284412 PMCID: PMC8905293 DOI: 10.3389/fbioe.2022.830776
Source DB: PubMed Journal: Front Bioeng Biotechnol ISSN: 2296-4185
FIGURE 1The operation process. (A) Application of riboflavin. (B) According to the corneal topography, UVA was applied in a sector shape. (C) According to the corneal topography, UVA was applied in a circular shape.
Ocular examination results at each follow-up point.
| pre | 1w po | 1 m po | 3 m po | 6 m po | 1 year po | |
|---|---|---|---|---|---|---|
| UDVA (logMAR) (mean ± SD) | 0.67 ± 0.09 | 0.48 ± 0.07 | 0.48 ± 0.07 | 0.49 ± 0.07 | 0.60 ± 0.07 | 0.52 ± 0.08 |
| CDVA (logMAR) (mean ± SD) | 0.09 ± 0.04 | 0.04 ± 0.03 | 0.03 ± 0.02 | 0.02 ± 0.03 | 0.05 ± 0.04 | 0.05 ± 0.04 |
| SE(D) (mean ± SD) | −3.62 ± 0.39 | −3.30 ± 0.35 | −3.23 ± 0.32 | −3.07 ± 0.32 | −3.01 ± 0.34 | −2.90 ± 0.34 |
| Steep K(D) (mean ± SD) | 46.44 ± 40.70 | 46.13 ± 0.65 | 46.29 ± 0.66 | 46.19 ± 0.65 | 46.17 ± 0.64 | 46.15 ± 0.60 |
| Flat K(D) (mean ± SD) | 44.40 ± 0.44 | 44.14 ± 0.41 | 44.28 ± 0.44 | 44.24 ± 0.42 | 44.19 ± 0.41 | 44.28 ± 0.44 |
| K max(D) (mean ± SD) | 49.13 ± 1.22 | 48.98 ± 1.22 | 49.11 ± 1.31 | 48.76 ± 1.09 | 48.77 ± 1.14 | 48.82 ± 1.16 |
| TCT (μm) (mean ± SD) | 497.25 ± 5.69 | 485.69 ± 6.62 | 489.38 ± 6.29 | 493.94 ± 6.67 | 492.25 ± 7.07 | 492.00 ± 6.86 |
| ECD (mean ± SD) | 3,095.01 ± 98.85 | 3,016.15 ± 122.88 | 3,047.27 ± 104.38 | 3,255.69 ± 109.20 | 3,307.11 ± 116.27 | 3,269.93 ± 126.46 |
UDVA uncorrected distant visual acuity; CDVA corrected distance visual acuity; SE spherical equivalent; TCT thinnest corneal thick; ECD endothelial cell density.
FIGURE 2The UCVA of most patients was higher than the pre-operative value, and the UCVA of nearly 1/3 of the patients was enhanced by at least 3 lines at each follow-up visit.
FIGURE 3Illustration of a typical case showing the shape of corneal cone changed during the whole follow-up period after the operation (A) Anterior surface of cornea before operation. (B) Corneal curvature decreased and cone shape changed at 1 week after operation. (C) Further changes in the shape of the cone 3 months after operation. (D) The curvature of the cone decreased and its shape changed continually at 1 year after operation.