| Literature DB >> 35268275 |
Clemens Kösters1, Daniel den Toom1, Sven Märdian2, Steffen Roßlenbroich3, Sebastian Metzlaff4, Kiriakos Daniilidis5, Jens Everding3.
Abstract
Internal fixation using angle stable plates is the treatment standard in periprosthetic fractures around stable implants. To provide instant postoperative full weight-bearing, bicortical screw fixation is advisable but often surgically demanding. This work presents the first clinical results of the LOQTEQ® VA Periprosthetic Plate (aap Implantate AG, Berlin, Germany), a new plate system to simplify screw placement around implants. This plate system uses insertable hinges that allow for variable angle screw anchorage. Data of 26 patients with a mean age of 80 years and a mean follow-up of 13.9 months were retrospectively collected. Patients were clinically and radiologically examined. Bony union was achieved in 14 out of 15 patients with no signs of non-union or implant loosening. One patient, however, presented with implant failure. Clinical scores demonstrated acceptable results. Since the hinge plates are easy to apply, the first results are promising.Entities:
Keywords: bicortical screw fixation; hinge plate; periprosthetic fracture; plate osteosynthesis
Year: 2022 PMID: 35268275 PMCID: PMC8911225 DOI: 10.3390/jcm11051184
Source DB: PubMed Journal: J Clin Med ISSN: 2077-0383 Impact factor: 4.241
Figure 1Locking attachment plate (Depuy-Synthes, Solothurn, Switzerland).
Figure 2LOQTEQ® VA Periprosthetic Plate (aap Implantate AG, Berlin, Germany).
Patient and study characteristics.
| Age (Year) | 80 (SD 11) |
|
|---|---|---|
| Sex | Female | 22 |
| Male | 4 | |
| ASA | ASA1 | 1 |
| ASA2 | 5 | |
| ASA3 | 12 | |
| ASA4 | 8 | |
| ASA5 | 0 | |
| Fracture side | Left | 14 |
| Right | 12 | |
| UCS Classification | IV.3-B1 | 5x |
| IV.3-C | 3x | |
| V.3-B1 | 8x | |
| V.3-B3 | 1x | |
| V.3-C | 3x | |
| V.3D | 6x | |
| Follow-up (month) | 13.9 (SD 12) |
Figure 3Hinge-technique with variable angle stable screw options, intraoperative and radiologic view.
Figure 4Freehand drill guide for 3.5 mm variable angle stable screws.
Figure 5Periprosthetic fracture around a cemented total hip revision stem, postoperative x-rays of double plating using the hinge-technique for bicortical screw fixation, intraoperative view.
Intra- and postoperative data.
| Patient | OP-Time (min) | Double Plate | HHP * | KSS ** | WOMAC *** | VAS **** | Complications | Fracture Healing |
|---|---|---|---|---|---|---|---|---|
| 1 | 127 | No | 59 | 144 | 20 | 2 | Yes | |
| 2 | 273 | Yes | 77 | 129 | 35 | 0 | Yes | |
| 3 | 191 | No | 99 | 169 | 11 | 0 | Yes | |
| 4 | 307 | No | 42 | 25 | 73 | 4 | sec. dislocation | Yes |
| 5 | 198 | No | 65 | 80 | 36 | 3 | Yes | |
| 6 | 173 | Yes | 37 | 65 | 62 | 3 | Yes | |
| 7 | 128 | Yes | 40 | 113 | 55 | 2 | Yes | |
| 8 | 113 | No | 78 | 175 | 22 | 5 | hematoma | Yes |
| 9 | 125 | No | 94 | 194 | 17 | 2 | Yes | |
| 10 | 113 | Yes | 90 | 169 | 13 | 0 | hematoma | Yes |
| 11 | 54 | Yes | 17 | 47 | 71 | 5 | Yes | |
| 12 | 87 | Yes | 29 | 42 | 62 | 6 | Yes | |
| 13 | 106 | No | 93 | 185 | 12 | 2 | Yes | |
| 14 | 272 | Yes | 63 | 122 | 46 | 2 | Yes | |
| 15 | 208 | Yes | - | - | - | 5 | implant failure | No |
* Harris Hip Score, ** Knee Society Score, *** Western Ontario and McMaster Universities Osteoarthritis Index, **** Visual Analogue Scale.