Literature DB >> 3522625

Routine evaluation of the nonradiometric BACTEC NR 660 system.

R J Courcol, A Fruchart, M Roussel-Delvallez, G R Martin.   

Abstract

The present study compares the sensitivity, accuracy, and practicability of a nonradiometric blood culture system with those of the standard blood culture system in use in our laboratory. A total of 1,080 sets of four blood cultures bottles were compared, giving 143 positive aerobic-medium associations and 139 positive anaerobic-medium associations. The conventional system recovered 171 isolates, whereas the BACTEC NR 660 system (Johnston Laboratories, Towson, Md.) recovered 155 isolated. There were no significant differences in total isolates with either system (P more than 0.05). The BACTEC NR 660 system recovered a slightly lower number of Serratia marcescens and Streptococcus faecalis but a higher number of Pneumococcus spp. The mean detection times were 55.9 h with the conventional system and 31.6 h with the BACTEC NR 660 system (P less than 0.001). Our results demonstrate that the BACTEC NR 660 system is suitable for routine use.

Entities:  

Mesh:

Year:  1986        PMID: 3522625      PMCID: PMC268825          DOI: 10.1128/jcm.24.1.26-29.1986

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  9 in total

1.  Evaluation of radiometric system for detecting bacteremia.

Authors:  E D Renner; L A Gatheridge; J A Washington
Journal:  Appl Microbiol       Date:  1973-09

2.  Radiometric detection of bacteremia in neonates.

Authors:  R M Bannatyne; N Harnett
Journal:  Appl Microbiol       Date:  1974-06

3.  Specimen volume versus yield in the BACTEC blood culture system.

Authors:  J J Plorde; F C Tenover; L G Carlson
Journal:  J Clin Microbiol       Date:  1985-08       Impact factor: 5.948

4.  Antibacterial activity in blood cultures.

Authors:  F Rodriguez; V Lorian
Journal:  J Clin Microbiol       Date:  1985-02       Impact factor: 5.948

5.  Laboratory experience with a radiometric method for detecting bacteremia.

Authors:  W A Thiemke; K Wicher
Journal:  J Clin Microbiol       Date:  1975-03       Impact factor: 5.948

6.  The importance of volume of blood cultured in the detection of bacteremia and fungemia.

Authors:  D M Ilstrup; J A Washington
Journal:  Diagn Microbiol Infect Dis       Date:  1983-06       Impact factor: 2.803

7.  Blood culture cross contamination associated with a radiometric analyzer.

Authors:  M R Griffin; A D Miller; A C Davis
Journal:  J Clin Microbiol       Date:  1982-04       Impact factor: 5.948

8.  Automated detection of Haemophilus influenzae.

Authors:  S M Larson; P Charache; M Chen; H N Wagner
Journal:  Appl Microbiol       Date:  1973-06

9.  Rapid diagnosis of bacteremia.

Authors:  S M Finegold; M L White; I Ziment; W R Winn
Journal:  Appl Microbiol       Date:  1969-09
  9 in total
  11 in total

1.  BioArgos: a fully automated blood culture system.

Authors:  R J Courcol; M Duhamel; A Decoster; V M Lemaire; M L Rastorgoueff; D Ochin; G R Martin
Journal:  J Clin Microbiol       Date:  1992-08       Impact factor: 5.948

2.  Assessment of the BACTEC NR660 blood culture system for the detection of bacteremia in young children.

Authors:  J D Anderson; C Trombley; N Cimolai
Journal:  J Clin Microbiol       Date:  1989-04       Impact factor: 5.948

3.  Determination of growth value thresholds for BACTEC PLUS aerobic blood culture vials.

Authors:  J E McGowan; B G Metchock
Journal:  J Clin Microbiol       Date:  1992-04       Impact factor: 5.948

4.  Rapid detection of positive blood cultures with the BACTEC NR-660 does not require first-day subculturing.

Authors:  M H Levi; P Gialanella; M R Motyl; J C McKitrick
Journal:  J Clin Microbiol       Date:  1988-11       Impact factor: 5.948

5.  Comparison of the automated Bactec NR-660 with a conventional blood culture system.

Authors:  A M van Elsacker-Niele; A T Lichtendahl-Bernards; J Hermans; J P Vandenbroucke; R P Mouton
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-08       Impact factor: 3.267

Review 6.  Detection of bloodstream infections in children.

Authors:  J M Campos
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

7.  Routine evaluation of BACTEC NR-16A and NR-17A media.

Authors:  R J Courcol; A V Durocher; M Roussel-Delvallez; A Fruchart; G R Martin
Journal:  J Clin Microbiol       Date:  1988-09       Impact factor: 5.948

8.  Survey of blood culture isolates in an area of Sweden from 1980 to 1986.

Authors:  L Sjöberg; H Fredlund
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1988-08       Impact factor: 3.267

9.  Influence of blood carbon dioxide pressure on growth index values in non-radiometric Bactec vials.

Authors:  R J Courcol; A V Durocher; H Robin; G R Martin
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-05       Impact factor: 3.267

10.  Occurrence of bacteremia in hematologic patients.

Authors:  D D'Antonio; E Pizzigallo; A Iacone; M Dell'Isola; G Fioritoni; S Betti; A Piergallini; R Di Gianfilippo; P Olioso; G Torlontano
Journal:  Eur J Epidemiol       Date:  1992-09       Impact factor: 8.082

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.